{"id":5404,"date":"2017-02-20T07:00:00","date_gmt":"2017-02-20T06:00:00","guid":{"rendered":"https:\/\/www.solerpalau.com\/blog\/es-es\/2017\/02\/20\/sistemas-dcv-monozona\/"},"modified":"2025-06-30T14:39:29","modified_gmt":"2025-06-30T12:39:29","slug":"sistemas-dcv-monozona","status":"publish","type":"post","link":"https:\/\/www.solerpalau.com\/blog\/es-es\/sistemas-dcv-monozona\/","title":{"rendered":"Sistemas DCV Monozona"},"content":{"rendered":"<h2><span class=\"ez-toc-section\" id=\"Descripcion\"><\/span>Descripci\u00f3n<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><span style=\"font-weight: 400;\">Se llama un sistema DCV monozona cuando el espacio a ventilar est\u00e1 compuesto por una sola \u00e1rea abierta, sin divisiones y que depende de un par\u00e1metro de control com\u00fan a la zona.<\/span><!--more--><\/p><div id=\"ez-toc-container\" class=\"ez-toc-v2_0_76 counter-hierarchy ez-toc-counter ez-toc-custom ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Tabla de contenidos<\/p>\n<span class=\"ez-toc-title-toggle\"><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.solerpalau.com\/blog\/es-es\/sistemas-dcv-monozona\/#Descripcion\" >Descripci\u00f3n<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.solerpalau.com\/blog\/es-es\/sistemas-dcv-monozona\/#Modos_de_control\" >Modos de control<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.solerpalau.com\/blog\/es-es\/sistemas-dcv-monozona\/#CAV_Caudal_Constante_de_Ventilacion\" >CAV (Caudal Constante de Ventilaci\u00f3n)<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/www.solerpalau.com\/blog\/es-es\/sistemas-dcv-monozona\/#VAV_Volumen_de_Aire_Variable\" >VAV (Volumen de Aire Variable)<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/www.solerpalau.com\/blog\/es-es\/sistemas-dcv-monozona\/#MINIMO-MAXIMO\" >MINIMO-M\u00c1XIMO<\/a><\/li><\/ul><\/nav><\/div>\n\n<p><span style=\"font-weight: 400;\">\u00c9ste tipo de sistema podr\u00eda ser adecuado, por ejemplo, en ventilaciones de una sala di\u00e1fana de oficinas, un despacho, una agrupaci\u00f3n de ba\u00f1os aislados o la zona principal de una tienda de ropa. \u00a0<\/span><\/p>\n<p>\u00a0<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Modos_de_control\"><\/span>Modos de control<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><span style=\"font-weight: 400;\">Un sistema DCV monozona var\u00eda el caudal de aire trasegado en funci\u00f3n de la variaci\u00f3n de la lectura del par\u00e1metro de control escogido (CO2, VOC, presencia, temperatura o humedad). Como ya se ha explicado en apartados anteriories, dependiendo del sensor seleccionado, el valor de lectura variar\u00e1 de una forma u otra. <\/span><\/p>\n<p><span style=\"font-weight: 400;\">Elementos que forman un sistema DCV monozona:<\/span><\/p>\n<ul>\n<li><b>Sensor:\u00a0<\/b><span style=\"font-weight: 400;\">concentraci\u00f3n CO2, presencia, temperatura, humedad o VOC.<\/span><span style=\"font-weight: 400;\"><br \/><\/span><b><\/b><\/li>\n<li><b>Controlador:\u00a0<\/b><span style=\"font-weight: 400;\">encargado de recibir la lectura del sensor y, dependiendo del modo de control utilizado, traducirla en una respuesta hacia el ventilador.<\/span><span style=\"font-weight: 400;\"><br \/><\/span><b><\/b><\/li>\n<li><b>Ventilador: <\/b><span style=\"font-weight: 400;\">para la ventilaci\u00f3n de una sola zona, podemos utilizar dos modos de control distintos para adecuarlos a las necesidades espec\u00edficas del local en funci\u00f3n de su uso.<\/span><\/li>\n<\/ul>\n<p>\u00a0<\/p>\n<h2><span class=\"ez-toc-section\" id=\"CAV_Caudal_Constante_de_Ventilacion\"><\/span><b><b>CAV (Caudal Constante de Ventilaci\u00f3n)<\/b><\/b><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><span style=\"font-weight: 400;\">\u00c9ste control se basa en garantizar siempre el mismo caudal, aunque cambien las circunstancias de la instalaci\u00f3n. Normalmente, esto suele suceder a causa del progresivo ensuciamiento de los filtros que, paulatinamente, van generando una mayor p\u00e9rdida de carga. Si disponemos de un CAV, el sistema ir\u00e1 incrementando la velocidad del ventilador al tiempo que aumenta la presi\u00f3n a vencer.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">El control CAV se aplica en casos donde un caudal m\u00ednimo p\u00e9rmanente de ventilaci\u00f3n sea necesario. \u00a0Quir\u00f3fanos de hospitales, ventilaci\u00f3n en viviendas o piscinas podr\u00edan ser buenos ejemplos.<\/span><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-739\" src=\"https:\/\/www.solerpalau.com\/blog\/es-es\/wp-content\/uploads\/2017\/02\/Screenshot-2017-02-16-at-7.23.33-PM.png\" alt=\"sistema monozona dcv\" width=\"490\" height=\"274\" \/><\/p>\n<h2><span class=\"ez-toc-section\" id=\"VAV_Volumen_de_Aire_Variable\"><\/span><b><b>VAV (Volumen de Aire Variable)<\/b><\/b><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><span style=\"font-weight: 400;\">Probablemente es el m\u00e9todo de control m\u00e1s com\u00fan en sistemas monozona y su objetivo es adecuar de forma permanente el caudal de aire a las necesidades del local. Seg\u00fan cual sea el par\u00e1metro que queremos controlar, se optar\u00e1 por un sensor u otro que enviar\u00e1 la se\u00f1al de lectura al m\u00f3dulo de control. <\/span><\/p>\n<p><span style=\"font-weight: 400;\">El control VAV se aplica en casos de ocupaci\u00f3n variable, como por ejemplo teatros, auditorios, bibliotecas, salas de reuni\u00f3n, zonas di\u00e1fanas de oficinas y locales comerciales.<\/span><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-738\" src=\"https:\/\/www.solerpalau.com\/blog\/es-es\/wp-content\/uploads\/2017\/02\/Screenshot-2017-02-16-at-7.23.44-PM.png\" alt=\"sisitema monozona dcv\" width=\"526\" height=\"287\" \/><\/p>\n<h2><span class=\"ez-toc-section\" id=\"MINIMO-MAXIMO\"><\/span><b><b>MINIMO-M\u00c1XIMO<\/b><\/b><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Es el modo de control m\u00e1s simple pero, a la vez, el menos optimizado. La regulaci\u00f3n del ventilador no es permanente sino que se limita a dos posiciones: ventilaci\u00f3n m\u00ednima y m\u00e1xima.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-737\" src=\"https:\/\/www.solerpalau.com\/blog\/es-es\/wp-content\/uploads\/2017\/02\/Screenshot-2017-02-16-at-7.23.54-PM.png\" alt=\"sistema monozona dcv\" width=\"489\" height=\"275\" \/><\/p>\n<p style=\"text-align: center;\"><\/p>\n<p>\u00a0<\/p>\n<p>\u00a0<\/p>\n\n\n<div class=\"hs-cta-embed hs-cta-simple-placeholder hs-cta-embed-125121583454\"\n  style=\"max-width:100%; max-height:100%; width:650px;height:311.3125px\" data-hubspot-wrapper-cta-id=\"125121583454\">\n  <a href=\"https:\/\/cta-service-cms2.hubspot.com\/web-interactives\/public\/v1\/track\/redirect?encryptedPayload=AVxigLL5uS7cfhUxmo63LZTYe1%2BrISI%2F%2BwN6zFD9ns2tHGq3kV%2F9L%2BH2WwC3IFK1Xx4RW6q9%2FzAm23WA2K8Dy3FHiQ%2Fc6FzthACBqhC2Dtdn%2FXZPHQBgLDm7Rdb3a90t9jAteFrJlz0PmNRhx%2Bda6WPVSWT%2FNT%2FrYJj14zWJMpU%2Bf1JTXihc7TpB3R6IlXcujZCrR9SkvOC4RWkmB70dRnpe4puR%2F3g%3D&#038;webInteractiveContentId=125121583454&#038;portalId=2009592\" target=\"_blank\" rel=\"noopener\" crossorigin=\"anonymous\">\n    <img decoding=\"async\" alt=\"GU&Iacute;A GRATUITA\" loading=\"lazy\" src=\"https:\/\/no-cache.hubspot.com\/cta\/default\/2009592\/interactive-125121583454.png\" style=\"height: 100%; width: 100%; object-fit: fill\"\n      onerror=\"this.style.display='none'\" \/>\n  <\/a>\n<\/div>\n\n","protected":false},"excerpt":{"rendered":"<p>Descripci\u00f3n Se llama un sistema DCV monozona cuando el espacio a ventilar est\u00e1 compuesto por una sola \u00e1rea abierta, sin divisiones y que depende de un par\u00e1metro de control com\u00fan a la zona.<\/p>\n","protected":false},"author":10,"featured_media":3673,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[3],"tags":[],"class_list":["post-5404","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-sostenibilidad-y-eficiencia-energetica"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.1 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Sistemas Demanda Controlada de Ventilaci\u00f3n Monozona<\/title>\n<meta name=\"description\" content=\"Un sistema DCV monozona est\u00e1 compuesto por una sola \u00e1rea abierta, sin divisiones y que depende de un par\u00e1metro de control com\u00fan a la zona.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.solerpalau.com\/blog\/es-es\/sistemas-dcv-monozona\/\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Sistemas Demanda Controlada de Ventilaci\u00f3n Monozona\" \/>\n<meta property=\"og:description\" content=\"Un sistema DCV monozona est\u00e1 compuesto por una sola \u00e1rea abierta, sin divisiones y que depende de un par\u00e1metro de control com\u00fan a la zona.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.solerpalau.com\/blog\/es-es\/sistemas-dcv-monozona\/\" \/>\n<meta property=\"og:site_name\" content=\"S&amp;P Sistemas de Ventilaci\u00f3n\" \/>\n<meta property=\"article:published_time\" content=\"2017-02-20T06:00:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-06-30T12:39:29+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.solerpalau.com\/blog\/es-es\/wp-content\/uploads\/sites\/3\/2025\/06\/iStock-471956015.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"699\" \/>\n\t<meta property=\"og:image:height\" content=\"500\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"S&amp;P\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t<meta name=\"twitter:data1\" content=\"S&amp;P\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tiempo de lectura\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutos\" \/>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Sistemas Demanda Controlada de Ventilaci\u00f3n Monozona","description":"Un sistema DCV monozona est\u00e1 compuesto por una sola \u00e1rea abierta, sin divisiones y que depende de un par\u00e1metro de control com\u00fan a la zona.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.solerpalau.com\/blog\/es-es\/sistemas-dcv-monozona\/","og_locale":"es_ES","og_type":"article","og_title":"Sistemas Demanda Controlada de Ventilaci\u00f3n Monozona","og_description":"Un sistema DCV monozona est\u00e1 compuesto por una sola \u00e1rea abierta, sin divisiones y que depende de un par\u00e1metro de control com\u00fan a la zona.","og_url":"https:\/\/www.solerpalau.com\/blog\/es-es\/sistemas-dcv-monozona\/","og_site_name":"S&amp;P Sistemas de Ventilaci\u00f3n","article_published_time":"2017-02-20T06:00:00+00:00","article_modified_time":"2025-06-30T12:39:29+00:00","og_image":[{"width":699,"height":500,"url":"https:\/\/www.solerpalau.com\/blog\/es-es\/wp-content\/uploads\/sites\/3\/2025\/06\/iStock-471956015.jpg","type":"image\/jpeg"}],"author":"S&amp;P","twitter_card":"summary_large_image","twitter_misc":{"Escrito por":"S&amp;P","Tiempo de lectura":"2 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.solerpalau.com\/blog\/es-es\/sistemas-dcv-monozona\/","url":"https:\/\/www.solerpalau.com\/blog\/es-es\/sistemas-dcv-monozona\/","name":"Sistemas Demanda Controlada de Ventilaci\u00f3n Monozona","isPartOf":{"@id":"https:\/\/www.solerpalau.com\/blog\/es-es\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.solerpalau.com\/blog\/es-es\/sistemas-dcv-monozona\/#primaryimage"},"image":{"@id":"https:\/\/www.solerpalau.com\/blog\/es-es\/sistemas-dcv-monozona\/#primaryimage"},"thumbnailUrl":"https:\/\/www.solerpalau.com\/blog\/es-es\/wp-content\/uploads\/sites\/3\/2025\/06\/iStock-471956015.jpg","datePublished":"2017-02-20T06:00:00+00:00","dateModified":"2025-06-30T12:39:29+00:00","author":{"@id":"https:\/\/www.solerpalau.com\/blog\/es-es\/#\/schema\/person\/a649fcc0fccdca5446ea2bc371ad5cb9"},"description":"Un sistema DCV monozona est\u00e1 compuesto por una sola \u00e1rea abierta, sin divisiones y que depende de un par\u00e1metro de control com\u00fan a la zona.","breadcrumb":{"@id":"https:\/\/www.solerpalau.com\/blog\/es-es\/sistemas-dcv-monozona\/#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.solerpalau.com\/blog\/es-es\/sistemas-dcv-monozona\/"]}]},{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/www.solerpalau.com\/blog\/es-es\/sistemas-dcv-monozona\/#primaryimage","url":"https:\/\/www.solerpalau.com\/blog\/es-es\/wp-content\/uploads\/sites\/3\/2025\/06\/iStock-471956015.jpg","contentUrl":"https:\/\/www.solerpalau.com\/blog\/es-es\/wp-content\/uploads\/sites\/3\/2025\/06\/iStock-471956015.jpg","width":699,"height":500,"caption":"sistemas dcv monozona"},{"@type":"BreadcrumbList","@id":"https:\/\/www.solerpalau.com\/blog\/es-es\/sistemas-dcv-monozona\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Inicio","item":"https:\/\/www.solerpalau.com\/blog\/es-es\/"},{"@type":"ListItem","position":2,"name":"Sistemas DCV Monozona"}]},{"@type":"WebSite","@id":"https:\/\/www.solerpalau.com\/blog\/es-es\/#website","url":"https:\/\/www.solerpalau.com\/blog\/es-es\/","name":"S&amp;P Sistemas de Ventilaci\u00f3n","description":"El Blog de ventilaci\u00f3n eficiente para una mejor calidad del aire","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.solerpalau.com\/blog\/es-es\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es"},{"@type":"Person","@id":"https:\/\/www.solerpalau.com\/blog\/es-es\/#\/schema\/person\/a649fcc0fccdca5446ea2bc371ad5cb9","name":"S&amp;P","image":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/www.solerpalau.com\/blog\/es-es\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/994644236667321375ba4d21a34a002e2bcfd7b33a114caa4c9dc488ece6c970?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/994644236667321375ba4d21a34a002e2bcfd7b33a114caa4c9dc488ece6c970?s=96&d=mm&r=g","caption":"S&amp;P"},"url":"https:\/\/www.solerpalau.com\/blog\/es-es\/author\/binaria\/"}]}},"reading_time":"<span class=\"span-reading-time rt-reading-time\"><span class=\"rt-label rt-prefix\"><\/span> <span class=\"rt-time\"> 3<\/span> <span class=\"rt-label rt-postfix\"> min. de lectura<\/span><\/span>","_links":{"self":[{"href":"https:\/\/www.solerpalau.com\/blog\/es-es\/wp-json\/wp\/v2\/posts\/5404","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.solerpalau.com\/blog\/es-es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.solerpalau.com\/blog\/es-es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.solerpalau.com\/blog\/es-es\/wp-json\/wp\/v2\/users\/10"}],"replies":[{"embeddable":true,"href":"https:\/\/www.solerpalau.com\/blog\/es-es\/wp-json\/wp\/v2\/comments?post=5404"}],"version-history":[{"count":1,"href":"https:\/\/www.solerpalau.com\/blog\/es-es\/wp-json\/wp\/v2\/posts\/5404\/revisions"}],"predecessor-version":[{"id":5905,"href":"https:\/\/www.solerpalau.com\/blog\/es-es\/wp-json\/wp\/v2\/posts\/5404\/revisions\/5905"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.solerpalau.com\/blog\/es-es\/wp-json\/wp\/v2\/media\/3673"}],"wp:attachment":[{"href":"https:\/\/www.solerpalau.com\/blog\/es-es\/wp-json\/wp\/v2\/media?parent=5404"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.solerpalau.com\/blog\/es-es\/wp-json\/wp\/v2\/categories?post=5404"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.solerpalau.com\/blog\/es-es\/wp-json\/wp\/v2\/tags?post=5404"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}