{"id":3991,"date":"2022-05-17T10:03:45","date_gmt":"2022-05-17T08:03:45","guid":{"rendered":"https:\/\/www.solerpalau.com\/blog\/it-it\/?p=3991"},"modified":"2025-04-15T14:07:56","modified_gmt":"2025-04-15T12:07:56","slug":"sovrapressione-scale-di-un-hotel-caso-pratico","status":"publish","type":"post","link":"https:\/\/www.solerpalau.com\/blog\/it-it\/sovrapressione-scale-di-un-hotel-caso-pratico\/","title":{"rendered":"Sovrapressione scale di un hotel: caso pratico"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_76 counter-hierarchy ez-toc-counter ez-toc-custom ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Sommario<\/p>\n<span class=\"ez-toc-title-toggle\"><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.solerpalau.com\/blog\/it-it\/sovrapressione-scale-di-un-hotel-caso-pratico\/#1_Obiettivo\" >1. Obiettivo<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.solerpalau.com\/blog\/it-it\/sovrapressione-scale-di-un-hotel-caso-pratico\/#2_Basi_di_calcolo\" >2. Basi di calcolo<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.solerpalau.com\/blog\/it-it\/sovrapressione-scale-di-un-hotel-caso-pratico\/#3_Metodologia_di_calcolo\" >3. Metodologia di calcolo<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/www.solerpalau.com\/blog\/it-it\/sovrapressione-scale-di-un-hotel-caso-pratico\/#4_Portata_scala\" >4. Portata scala<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/www.solerpalau.com\/blog\/it-it\/sovrapressione-scale-di-un-hotel-caso-pratico\/#5_Installazione_proposta\" >5. Installazione proposta<\/a><\/li><\/ul><\/nav><\/div>\n\n<p>Un caso pratico sulla sovrapressione delle scale di un hotel per aiutarti a capire meglio come affrontarlo.<\/p>\n\n\n\n<!--more-->\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"1_Obiettivo\"><\/span><b>1. Obiettivo<\/b><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Determinare il sistema e il tipo di ventilatori adatti per mettere in sovrapressione un vano scale ed un atrio di un hotel a 5 piani.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"2_Basi_di_calcolo\"><\/span><b>2. Basi di calcolo<\/b><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Trattasi di una scala di emergenza interna, senza accesso ad ascensori e con accesso a 5 piani tramite doppie porte di 1,2 x 2,1 m., mentre la porta di uscita al piano terra misura 1,12 x 2,1 m. L\u2019atrio da mettere in sovrapressione si trova al piano interrato con accesso a due scale, due servizi igienici e locali tecnici senza uscita sull&#8217;esterno.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"3_Metodologia_di_calcolo\"><\/span><b>3. Metodologia di calcolo<\/b><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Per Scala Protetta, si intende una scala con un tracciato continuo dall&#8217;inizio fino al pianerottolo al piano di uscita dell\u2019edificio che, in caso di incendio, costituisce un involucro sufficientemente sicuro da consentire agli occupanti di soggiornarvi per un certo tempo.<\/p>\n\n\n\n<p>A tal fine devono essere soddisfatte una serie di condizioni che, per quanto riguarda la protezione contro il fumo, possono essere:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Ventilazione naturale mediante finestre apribili o aperture verso l&#8217;esterno con una superficie di ventilazione di almeno 1 m2 per ogni piano.<\/li>\n\n\n\n<li>Ventilazione mediante condotti di ingresso e uscita aria separati, predisposti esclusivamente per tale funzione e conformi alle condizioni (prescritte).<\/li>\n\n\n\n<li>Sistema a pressione differenziale.\u201d<\/li>\n<\/ol>\n\n\n\n<p>Dato che nessuna delle due ipotesi iniziali \u00e8 soddisfatta, \u00e8 necessario utilizzare il metodo della sovrappressione, basato sulla norma UNE EN 12101-6.<\/p>\n\n\n\n<figure class=\"wp-block-image\"><img loading=\"lazy\" decoding=\"async\" width=\"1226\" height=\"500\" src=\"https:\/\/www.solerpalau.com\/blog\/it-it\/wp-content\/uploads\/sites\/4\/2022\/05\/Tabella-1-Classe-di-sistema.png\" alt=\"\" class=\"wp-image-3992\"\/><\/figure>\n\n\n\n<p><\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"4_Portata_scala\"><\/span><b>4. Portata scala<\/b><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Per determinare la portata necessaria per la sovrapressione, bisogna determinare in primo luogo la classe del sistema in base all\u2019uso dell\u2019edificio, secondo la tabella 1 della norma citata.<\/p>\n\n\n\n<p>In questo caso si presume si possa considerare un sistema di classe D, concepito per edifici in cui gli occupanti possono dormire, come nel caso degli hotel.<\/p>\n\n\n\n<p>Successivamente, \u00e8 necessario valutare quale sistema richieda la maggiore quantit\u00e0 d&#8217;aria per raggiungere la sovrappressione, in due differenti scenari: con una porta aperta o con tutte le porte chiuse e la compensazione delle perdite d&#8217;aria attraverso di esse.<\/p>\n\n\n\n<p>I calcoli corrispondenti dovrebbero essere realizzati tenendo conto del sistema di calcolo della portata con la porta aperta e della portata con le porte chiuse. Infine calcoliamo l&#8217;area delle perdite d\u2019aria e la differenza di pressione per calcolare la portata.<\/p>\n\n\n\n<p><\/p>\n\n\n\n<div class=\"hs-web-interactive-inline\" style=\"\" data-hubspot-wrapper-cta-id=\"188598457711\"> \n <style data-hubspot-cta-style=\"hs-inline-web-interactive-188598457711\">\n\n  a.hs-inline-web-interactive-188598457711link {\n    text-decoration:none;\n  }\n\n  a.hs-inline-web-interactive-188598457711hover {\n    text-decoration:none;\n  }\n\n<\/style> \n <a href=\"https:\/\/cta-service-cms2.hubspot.com\/web-interactives\/public\/v1\/track\/click?encryptedPayload=AVxigLL3P1MRg4RYaIkhW1g1E3yROMwIAoxQRRk09L3TR7YDZA133gzV03lMr3zYupMp0zLRFBGiTY0xYgv4yo3qCVta8wo6uCxdZkoSyei1pyFpNanQPn6suy7hUzou5Mx79jQBR%2Fl7s1hkNAh0gTNiMvzx649fXXnyWC15yZBuBkl7pzsLXeqUr7yjxVCHyMqV8jaGPW2SkHO22xbOr3q2oAFUgGkeMlWpSDa8kmEd%2F0TRrrl3SfWASLvZZqhKEfea8kA1TfC7eL48zXnGqJH9&amp;portalId=2009592\" target=\"_blank\" rel=\"noopener\" class=\"hs-inline-web-interactive-188598457711   \" data-hubspot-cta-id=\"188598457711\"> \n  <div style=\"font-size: 18px; text-align: center;\">\n   <span style=\"color: #ce1a1a; font-family: Arial, Helvetica, sans-serif;\"><strong>Caso studio | <\/strong>Soluzioni&nbsp;di ventilazione nella ristrutturazione dell&#8217;edificio storico La Estaci\u00f3n 86 a Ortuella &#8211; <strong>SCARICA QUI<\/strong><\/span>\n  <\/div> <\/a> \n<\/div>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"5_Installazione_proposta\"><\/span><b>5. Installazione proposta<\/b><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Oltre alla portata, bisogna tenere presente i seguenti criteri:<\/p>\n\n\n\n<p>5.2.2.3 Negli edifici di altezza pari o superiore a 11 m, i punti di immissione dell\u2019aria devono essere distribuiti uniformemente lungo tutta l\u2019altezza del vano scala, e la distanza massima non pu\u00f2 superare i 3 piani.<\/p>\n\n\n\n<p>11.6.1 Per ridurre il rischio di interruzione dell&#8217;energia elettrica in caso di incendio, \u00e8 essenziale disporre di una fonte di alimentazione secondaria, come un generatore o una sottostazione indipendente, con una capacit\u00e0 sufficiente a mantenere l&#8217;alimentazione elettrica degli impianti di sicurezza e protezione antincendio, compresi i sistemi di controllo del fumo, i sistemi di pressione differenziale e le attrezzature ausiliarie.<\/p>\n\n\n\n<p>11.8.2.4 La presa d&#8217;aria esterna deve essere sempre posizionata lontano da qualsiasi punto di possibile rischio di incendio. Le prese d&#8217;aria esterne devono essere posizionate al livello del piano terra o in prossimit\u00e0 di esse (ma lontane dalle prese d\u2019aria del seminterrato) per evitare la contaminazione dovuta al fumo che sale. Se tale disposizione non \u00e8 possibile, le prese d&#8217;aria esterna devono essere posizionate a livello del tetto.<\/p>\n\n\n\n<p>11.8.2.6 Quando la presa d&#8217;aria non \u00e8 al livello del tetto, \u00e8 necessario posizionare un rilevatore di fumo nel condotto di aspirazione dell&#8217;aria esterna, o nelle immediate vicinanze del condotto di immissione, in modo da provocare l\u2019arresto automatico del sistema di pressione differenziale nel caso ci fosse una grande quantit\u00e0 di fumo nell&#8217;aria di mandata. Deve essere previsto un interruttore manuale per un possibile utilizzo da parte dei vigili del fuoco in tali circostanze, in conformit\u00e0 con la sezione 11.4.2.5.<\/p>\n\n\n\n<p>11.8.2.7 Quando le prese d&#8217;aria sono poste a livello del tetto, devono essere presenti due aperture separate e dirette in direzioni diverse, in modo da non essere soggette alle stesse fonti di fumi. Ogni ingresso deve essere in grado da solo di fornire l\u2019intero fabbisogno d&#8217;aria esterna, e deve essere dotato di una serranda fumi motorizzata con funzionamento indipendente, in modo che se una serranda si chiude a causa della contaminazione da fumo, l&#8217;altro ingresso fornisca senza interruzioni la portata d\u2019aria esterna richiesta dal sistema.<\/p>\n\n\n\n<!--HubSpot Call-to-Action Code --><span class=\"hs-cta-wrapper\" id=\"hs-cta-wrapper-cf1136a1-339b-4702-a4b4-88f40ff6023b\"><span class=\"hs-cta-node hs-cta-cf1136a1-339b-4702-a4b4-88f40ff6023b\" id=\"hs-cta-cf1136a1-339b-4702-a4b4-88f40ff6023b\"><!--[if lte IE 8]><div id=\"hs-cta-ie-element\"><\/div><![endif]--><a href=\"https:\/\/cta-redirect.hubspot.com\/cta\/redirect\/2009592\/cf1136a1-339b-4702-a4b4-88f40ff6023b\" ><img decoding=\"async\" class=\"hs-cta-img\" id=\"hs-cta-img-cf1136a1-339b-4702-a4b4-88f40ff6023b\" style=\"border-width:0px;\" src=\"https:\/\/no-cache.hubspot.com\/cta\/default\/2009592\/cf1136a1-339b-4702-a4b4-88f40ff6023b.png\"  alt=\"Nueva llamada a la acci\u00f3n\"\/><\/a><\/span><script charset=\"utf-8\" src=\"https:\/\/js.hscta.net\/cta\/current.js\"><\/script><script type=\"text\/javascript\"> hbspt.cta.load(2009592, 'cf1136a1-339b-4702-a4b4-88f40ff6023b', {\"useNewLoader\":\"true\",\"region\":\"na1\"}); <\/script><\/span><!-- end HubSpot Call-to-Action Code -->\n","protected":false},"excerpt":{"rendered":"<p>Un caso pratico sulla sovrapressione delle scale di un hotel per aiutarti a capire meglio come affrontarlo.<\/p>\n","protected":false},"author":10,"featured_media":3993,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[9],"tags":[],"class_list":["post-3991","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-casi-studio"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.1 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Sovrapressione scale di un hotel: caso pratico | S&amp;P<\/title>\n<meta name=\"description\" content=\"Un caso pratico sulla sovrapressione delle scale di un hotel per aiutarti a capire meglio come affrontarlo.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.solerpalau.com\/blog\/it-it\/sovrapressione-scale-di-un-hotel-caso-pratico\/\" \/>\n<meta property=\"og:locale\" content=\"it_IT\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Sovrapressione scale di un hotel: caso pratico | S&amp;P\" \/>\n<meta property=\"og:description\" content=\"Un caso pratico sulla sovrapressione delle scale di un hotel per aiutarti a capire meglio come affrontarlo.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.solerpalau.com\/blog\/it-it\/sovrapressione-scale-di-un-hotel-caso-pratico\/\" \/>\n<meta property=\"og:site_name\" content=\"S&amp;P Sistemi di ventilazione\" \/>\n<meta property=\"article:published_time\" content=\"2022-05-17T08:03:45+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-04-15T12:07:56+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.solerpalau.com\/blog\/it-it\/wp-content\/uploads\/sites\/4\/2022\/05\/sobrepresion-escaleras-hotel-1.jpeg\" \/>\n\t<meta property=\"og:image:width\" content=\"732\" \/>\n\t<meta property=\"og:image:height\" content=\"478\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"S&amp;P\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Scritto da\" \/>\n\t<meta name=\"twitter:data1\" content=\"S&amp;P\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tempo di lettura stimato\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minuti\" \/>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Sovrapressione scale di un hotel: caso pratico | S&P","description":"Un caso pratico sulla sovrapressione delle scale di un hotel per aiutarti a capire meglio come affrontarlo.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.solerpalau.com\/blog\/it-it\/sovrapressione-scale-di-un-hotel-caso-pratico\/","og_locale":"it_IT","og_type":"article","og_title":"Sovrapressione scale di un hotel: caso pratico | S&P","og_description":"Un caso pratico sulla sovrapressione delle scale di un hotel per aiutarti a capire meglio come affrontarlo.","og_url":"https:\/\/www.solerpalau.com\/blog\/it-it\/sovrapressione-scale-di-un-hotel-caso-pratico\/","og_site_name":"S&amp;P Sistemi di ventilazione","article_published_time":"2022-05-17T08:03:45+00:00","article_modified_time":"2025-04-15T12:07:56+00:00","og_image":[{"width":732,"height":478,"url":"https:\/\/www.solerpalau.com\/blog\/it-it\/wp-content\/uploads\/sites\/4\/2022\/05\/sobrepresion-escaleras-hotel-1.jpeg","type":"image\/jpeg"}],"author":"S&amp;P","twitter_card":"summary_large_image","twitter_misc":{"Scritto da":"S&amp;P","Tempo di lettura stimato":"5 minuti"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.solerpalau.com\/blog\/it-it\/sovrapressione-scale-di-un-hotel-caso-pratico\/","url":"https:\/\/www.solerpalau.com\/blog\/it-it\/sovrapressione-scale-di-un-hotel-caso-pratico\/","name":"Sovrapressione scale di un hotel: caso pratico | S&P","isPartOf":{"@id":"https:\/\/www.solerpalau.com\/blog\/it-it\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.solerpalau.com\/blog\/it-it\/sovrapressione-scale-di-un-hotel-caso-pratico\/#primaryimage"},"image":{"@id":"https:\/\/www.solerpalau.com\/blog\/it-it\/sovrapressione-scale-di-un-hotel-caso-pratico\/#primaryimage"},"thumbnailUrl":"https:\/\/www.solerpalau.com\/blog\/it-it\/wp-content\/uploads\/sites\/4\/2022\/05\/sobrepresion-escaleras-hotel-1.jpeg","datePublished":"2022-05-17T08:03:45+00:00","dateModified":"2025-04-15T12:07:56+00:00","author":{"@id":"https:\/\/www.solerpalau.com\/blog\/it-it\/#\/schema\/person\/a649fcc0fccdca5446ea2bc371ad5cb9"},"description":"Un caso pratico sulla sovrapressione delle scale di un hotel per aiutarti a capire meglio come affrontarlo.","breadcrumb":{"@id":"https:\/\/www.solerpalau.com\/blog\/it-it\/sovrapressione-scale-di-un-hotel-caso-pratico\/#breadcrumb"},"inLanguage":"it-IT","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.solerpalau.com\/blog\/it-it\/sovrapressione-scale-di-un-hotel-caso-pratico\/"]}]},{"@type":"ImageObject","inLanguage":"it-IT","@id":"https:\/\/www.solerpalau.com\/blog\/it-it\/sovrapressione-scale-di-un-hotel-caso-pratico\/#primaryimage","url":"https:\/\/www.solerpalau.com\/blog\/it-it\/wp-content\/uploads\/sites\/4\/2022\/05\/sobrepresion-escaleras-hotel-1.jpeg","contentUrl":"https:\/\/www.solerpalau.com\/blog\/it-it\/wp-content\/uploads\/sites\/4\/2022\/05\/sobrepresion-escaleras-hotel-1.jpeg","width":732,"height":478},{"@type":"BreadcrumbList","@id":"https:\/\/www.solerpalau.com\/blog\/it-it\/sovrapressione-scale-di-un-hotel-caso-pratico\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.solerpalau.com\/blog\/it-it\/"},{"@type":"ListItem","position":2,"name":"Sovrapressione scale di un hotel: caso pratico"}]},{"@type":"WebSite","@id":"https:\/\/www.solerpalau.com\/blog\/it-it\/#website","url":"https:\/\/www.solerpalau.com\/blog\/it-it\/","name":"S&amp;P Sistemi di ventilazione","description":"Il blog della ventilazione efficiente","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.solerpalau.com\/blog\/it-it\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"it-IT"},{"@type":"Person","@id":"https:\/\/www.solerpalau.com\/blog\/it-it\/#\/schema\/person\/a649fcc0fccdca5446ea2bc371ad5cb9","name":"S&amp;P","image":{"@type":"ImageObject","inLanguage":"it-IT","@id":"https:\/\/www.solerpalau.com\/blog\/it-it\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/994644236667321375ba4d21a34a002e2bcfd7b33a114caa4c9dc488ece6c970?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/994644236667321375ba4d21a34a002e2bcfd7b33a114caa4c9dc488ece6c970?s=96&d=mm&r=g","caption":"S&amp;P"},"url":"https:\/\/www.solerpalau.com\/blog\/it-it\/author\/binaria\/"}]}},"reading_time":"<span class=\"span-reading-time rt-reading-time\"><span class=\"rt-label rt-prefix\"><\/span> <span class=\"rt-time\"> 3<\/span> <span class=\"rt-label rt-postfix\"> min. di lettura<\/span><\/span>","_links":{"self":[{"href":"https:\/\/www.solerpalau.com\/blog\/it-it\/wp-json\/wp\/v2\/posts\/3991","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.solerpalau.com\/blog\/it-it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.solerpalau.com\/blog\/it-it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.solerpalau.com\/blog\/it-it\/wp-json\/wp\/v2\/users\/10"}],"replies":[{"embeddable":true,"href":"https:\/\/www.solerpalau.com\/blog\/it-it\/wp-json\/wp\/v2\/comments?post=3991"}],"version-history":[{"count":3,"href":"https:\/\/www.solerpalau.com\/blog\/it-it\/wp-json\/wp\/v2\/posts\/3991\/revisions"}],"predecessor-version":[{"id":5515,"href":"https:\/\/www.solerpalau.com\/blog\/it-it\/wp-json\/wp\/v2\/posts\/3991\/revisions\/5515"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.solerpalau.com\/blog\/it-it\/wp-json\/wp\/v2\/media\/3993"}],"wp:attachment":[{"href":"https:\/\/www.solerpalau.com\/blog\/it-it\/wp-json\/wp\/v2\/media?parent=3991"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.solerpalau.com\/blog\/it-it\/wp-json\/wp\/v2\/categories?post=3991"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.solerpalau.com\/blog\/it-it\/wp-json\/wp\/v2\/tags?post=3991"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}