{"id":5069,"date":"2024-07-11T15:48:50","date_gmt":"2024-07-11T13:48:50","guid":{"rendered":"https:\/\/www.solerpalau.com\/blog\/it-it\/?p=5069"},"modified":"2025-12-03T16:28:23","modified_gmt":"2025-12-03T15:28:23","slug":"ventilazione-delle-aree-comuni-e-dei-vani-scala-e-protezione-antincendio","status":"publish","type":"post","link":"https:\/\/www.solerpalau.com\/blog\/it-it\/ventilazione-delle-aree-comuni-e-dei-vani-scala-e-protezione-antincendio\/","title":{"rendered":"Ventilazione delle aree comuni e dei vani scala e protezione antincendio"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_76 counter-hierarchy ez-toc-counter ez-toc-custom ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Sommario<\/p>\n<span class=\"ez-toc-title-toggle\"><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.solerpalau.com\/blog\/it-it\/ventilazione-delle-aree-comuni-e-dei-vani-scala-e-protezione-antincendio\/#Codice_di_Prevenzione_Incendi_Esodo\" >Codice di Prevenzione Incendi; Esodo<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.solerpalau.com\/blog\/it-it\/ventilazione-delle-aree-comuni-e-dei-vani-scala-e-protezione-antincendio\/#Ventilazione_delle_scale_in_base_alla_loro_tipologia\" >Ventilazione delle scale in base alla loro tipologia<\/a><\/li><\/ul><\/nav><\/div>\n<p class=\"p1\"><span class=\"s1\">La <b>ventilazione delle aree comuni e delle scale <\/b>interne di un edificio \u00e8 un aspetto fondamentale per garantire l&#8217;abitabilit\u00e0, il comfort e la sicurezza degli edifici e dei loro occupanti. Nonostante le scale siano aree di comunicazione che trasferiscono odori e inquinanti, non normativa specifica per la ventilazione in questi spazi se non in qualche caso all\u2019interno di regolamenti edilizi comunali locali.<\/span><!--more--><\/p>\n<p class=\"p1\"><span class=\"s1\">Oltre a questi aspetti legati alla <a href=\"https:\/\/www.solerpalau.com\/blog\/it-it\/come-raggiungere-la-temperatura-di-comfort\/\" target=\"_blank\" rel=\"noopener\">salute e al comfort<\/a> nell&#8217;edificio, \u00e8 molto importante definire adeguatamente la <b>strategia di protezione di queste aree in caso di incendio,<\/b> poich\u00e9 le loro caratteristiche possono agire come propagatori di fuoco e fumo.<\/span><\/p>\n<p class=\"p1\"><span class=\"s1\">Lo scopo di queste aree comuni \u00e8 quello di consentire la circolazione tra i piani. In caso di incendio, anche se il fuoco non \u00e8 localizzato in quest&#8217;area, la presenza di fumo ne impedisce l&#8217;utilizzo per l&#8217;evacuazione delle persone. Poich\u00e9 per\u00f2 queste aree fanno spesso parte del sistema di vie di esodo, ne deve essere garantita l\u2019agibilit\u00e0 anche in caso di Incendio. Nel Codice di Prevenzione Incendi <a href=\"https:\/\/www.gazzettaufficiale.it\/eli\/id\/2019\/10\/31\/19A06608\/sg\" target=\"_blank\" rel=\"noopener\">(DM 3 agosto 2015 modificato dal DM 18 ottobre 2019)<\/a> vi \u00e8 una sezione ampiamente dedicata proprio a questo importante tema di sicurezza, che da anche specifiche indicazioni sulle scale afferenti al sistema di vie di esodo.<\/span><\/p>\n<h2 class=\"p1\"><span class=\"ez-toc-section\" id=\"Codice_di_Prevenzione_Incendi_Esodo\"><\/span><span class=\"s1\"><b>Codice di Prevenzione Incendi; Esodo<\/b><\/span><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p class=\"p1\"><span class=\"s1\">Nel Codice di Prevenzione Incendi si stabilisce che gli edifici devono avere le attrezzature e gli impianti di protezione antincendio indicati nella normativa stessa. In particolare nel Capitolo S.4 delle Sezione S (Strategia antincendio) il Codice definisce come devono essere le vie di esodo, premettendo che\u00a0 \u201cLa finalit\u00e0 del sistema d\u2019esodo \u00e8 di assicurare che gli occupanti dell\u2019attivit\u00e0 possano raggiungere un luogo sicuro o permanere al sicuro, autonomamente o con assistenza, prima che l\u2019incendio determini condizioni incapacitanti negli ambiti dell\u2019attivit\u00e0 ove si trovano\u201d e che \u201cIl sistema d\u2019esodo deve assicurare la prestazione richiesta a prescindere dall\u2019intervento dei Vigili del fuoco\u201d.<\/span><\/p>\n<p class=\"p1\"><span class=\"s1\">La progettazione, l&#8217;esecuzione, la messa in funzione e la manutenzione, cos\u00ec come i materiali, i componenti e le attrezzature, devono quindi essere conformi a quanto riportato nel Codice nelle sue varie Sezioni e Capitoli. Col DM 3 agosto 2015 e l\u2019introduzione del Codice di Prevenzione Incendi (e successivi aggiornamenti), tra le tante innovazioni portate, ha standardizzato le regole di prevenzioni incendi adeguando il linguaggio agli standard internazionali e integrando quanto gi\u00e0 previsto nei documenti preesistenti in Italia in ambito di prevenzione incendi, il tutto in un unico testo di riferimento.<\/span><\/p>\n<p class=\"p1\"><span class=\"s1\">Gli spazi e le aree comuni, come le scale, richiedono una serie di condizioni specifiche che dipendono da vari parametri da tenere in considerazione per la protezione e l&#8217;evacuazione degli occupanti di un edificio o di un&#8217;abitazione.<\/span><\/p>\n<h3 class=\"p1\"><span class=\"s1\"><b>Differenze tra le scale<\/b><\/span><\/h3>\n<p class=\"p1\"><span class=\"s1\">Nel<b> Codice di Prevenzione Incendi<\/b> vengono definite differenti tipologie di vie d\u2019esodo; differenziazione che \u00e8 applicata anche alle scale:<\/span><\/p>\n<ul class=\"ul1\">\n<li class=\"li1\"><span class=\"s1\">Scala protetta<\/span><\/li>\n<li class=\"li1\"><span class=\"s1\">Scala a prova di fumo<\/span><\/li>\n<li class=\"li1\"><span class=\"s1\">Scala esterna<\/span><\/li>\n<li class=\"li1\"><span class=\"s1\">Scala senza protezione<\/span><\/li>\n<\/ul>\n<h3 class=\"p1\"><span class=\"s1\"><b>Requisiti in base alle caratteristiche delle scale<\/b><\/span><\/h3>\n<p class=\"p1\"><span class=\"s1\">Tutte le scale d\u2019esodo devono soddisfare i <b>requisiti di abitabilit\u00e0, accessibilit\u00e0 e sicurezza d&#8217;uso<\/b> anche da un punto di vista puramente architettonico<b>.<\/b> Le scale d\u2019esodo devono rispettare tra gli altri una serie di parametri riportati nel Capitolo S.4.5.4:<\/span><\/p>\n<ol class=\"ol1\">\n<li class=\"li1\"><span class=\"s1\">Quando un pavimento inclinato immette in una scala d\u2019esodo, la pendenza deve interrompersi almeno ad una distanza dalla scala pari alla larghezza della stessa.<\/span><\/li>\n<li class=\"li1\"><span class=\"s1\">Le scale d\u2019esodo devono essere dotate di corrimano laterale. Le scale d\u2019esodo di larghezza maggiore di 2400 mm dovrebbero essere dotate di uno o pi\u00f9 corrimano centrali.<\/span><\/li>\n<li class=\"li1\"><span class=\"s1\">Le scale d\u2019esodo devono consentire l\u2019esodo senza inciampo degli occupanti. A tal fine:<\/span>\n<ol class=\"ol1\">\n<li class=\"li1\"><span class=\"s1\">i gradini devono avere alzata e pedata costanti;<\/span><\/li>\n<li class=\"li1\"><span class=\"s1\">devono essere interrotte da pianerottoli di sosta.<\/span><\/li>\n<\/ol>\n<\/li>\n<li class=\"li1\"><span class=\"s1\">Sono ammessi gradini con alzata o pedata variabili, per brevi tratti segnalati, lungo le vie d\u2019esodo da ambiti ove vi sia esclusiva presenza di personale specificamente formato od occasionale e di breve durata di un numero limitato di occupanti (es. locali impianti o di servizio, piccoli depositi, \u2026), oppure secondo le risultanze di specifica valutazione del rischio.<\/span><\/li>\n<li class=\"li1\"><span class=\"s1\">Dovrebbero essere evitate scale d\u2019esodo composte da un solo gradino in quanto fonte d\u2019inciampo. Se il gradino singolo non \u00e8 eliminabile, deve essere opportunamente segnalato.<\/span><\/li>\n<\/ol>\n<h2 class=\"p1\"><span class=\"ez-toc-section\" id=\"Ventilazione_delle_scale_in_base_alla_loro_tipologia\"><\/span><span class=\"s1\"><b>Ventilazione delle scale in base alla loro tipologia<\/b><\/span><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p class=\"p1\"><span class=\"s1\">Ogni tipo di scala richiede<a href=\"https:\/\/www.solerpalau.com\/blog\/it-it\/qual-e-il-miglior-sistema-di-ventilazione-per-un-edificio-a-basso-consumo-energetico\/\" target=\"_blank\" rel=\"noopener\"> un sistema di ventilazione adeguato<\/a> alle sue caratteristiche, secondo la classificazione di cui sopra. Queste possono essere: protette, a prova di fumo, esterne, senza protezione.<\/span><\/p>\n<p class=\"p1\"><span class=\"s1\">Le scale d\u2019esodo devono essere adeguatamente protette in modo che il fumo ed il calore dell\u2019incendio smaltiti o evacuati dall\u2019attivit\u00e0 non devono interferire con esse e devono condurre in luogo sicuro direttamente o tramite percorso d\u2019esodo di tipologia uguale a quella della scala (protetta, a prova di fumo o esterna).<\/span><\/p>\n<p class=\"p1\"><span class=\"s1\">Le scale a prova di fumo devono inoltre soddisfare requisiti di ventilazione molto specifici.<\/span><\/p>\n<h3 class=\"p1\"><span class=\"s1\"><b>Sistemi per la ventilazione di scale a prova di fumo<\/b><\/span><\/h3>\n<p class=\"p1\"><span class=\"s1\">I sistemi pi\u00f9 utilizzati per ventilare le scale a prova di fumo sono tre:<\/span><\/p>\n<ol class=\"ol1\">\n<li class=\"li1\"><b><\/b><span class=\"s1\"><b>Ventilazione mediante condotti separati <\/b>di aspirazione e scarico dell&#8217;aria. In caso di incendio, l&#8217;aria fresca proveniente dall&#8217;esterno entra attraverso i condotti di aspirazione. L&#8217;aria fresca entra nella scala e i prodotti della combustione vengono scaricati attraverso il condotto di scarico. \u00c8 garantita l&#8217;assenza di contaminazione dell&#8217;aria in entrata, poich\u00e9 i condotti sono indipendenti l&#8217;uno dall&#8217;altro.<\/span><\/li>\n<li class=\"li1\"><b><\/b><span class=\"s1\"><b>Sistema di ventilazione a pressione differenziale: <\/b>utilizza ventilatori e sonde di pressione opportunamente distribuite. Questo sistema mantiene una pressione pi\u00f9 elevata nell&#8217;area da proteggere, in modo da impedirla. I sistemi a pressione differenziale, sia per sovrapressione che per estrazione forzata, sono considerati i pi\u00f9 appropriati per la protezione di alcune vie di fuga come corridoi, scale, atri, ecc.<\/span><\/li>\n<li class=\"li1\"><b><\/b><span class=\"s1\"><b>Ventilazione naturale<\/b> attraverso finestre a battente con un certo requisito di superficie minima. \u00c8 il metodo pi\u00f9 economico e semplice, ma anche quello che presenta maggiori problemi di funzionamento. Il suo corretto funzionamento dipende dalla corretta apertura delle finestre e dalle condizioni di pressione e temperatura dell&#8217;aria interna (inquinata o fumosa) ed esterna.<\/span><\/li>\n<\/ol>\n<p class=\"p1\"><span class=\"s1\"><b>Le scale devono essere analizzate e ventilate con particolare attenzione per ridurre e minimizzare il rischio per le persone in caso di incendio.<\/b><\/span><\/p>\n\n\n<div class=\"hs-cta-embed hs-cta-simple-placeholder hs-cta-embed-164703009898\"\n  style=\"max-width:100%; max-height:100%; width:650px;height:312.7083435058594px\" data-hubspot-wrapper-cta-id=\"164703009898\">\n  <a href=\"https:\/\/cta-service-cms2.hubspot.com\/web-interactives\/public\/v1\/track\/redirect?encryptedPayload=AVxigLKbdLz6j2KqpxUOnvIrcakLyvZGVdkFNxUCfqaz4Y2S9Y9dKYcZQrCqw%2Feof45P1SxG5bokplp7jw%2BHotZDCWQVPTkV89LOpRSz%2BGFPO1kbYmQo4GogNgOgx%2FgEafzdT49WHw%2FdY6pmTaSLIGJgk8k73hR0rw0XdMOAFZISu7txQMrPqZGh90zXFkDBcrjfZxpGz9%2Bd6N13TkpDasf8orJV1WYe9awoedldNmu6&#038;webInteractiveContentId=164703009898&#038;portalId=2009592\" target=\"_blank\" rel=\"noopener\" crossorigin=\"anonymous\">\n    <img decoding=\"async\" alt=\"GUIDA GRATUITA\" loading=\"lazy\" src=\"https:\/\/no-cache.hubspot.com\/cta\/default\/2009592\/interactive-164703009898.png\" style=\"height: 100%; width: 100%; object-fit: fill\"\n      onerror=\"this.style.display='none'\" \/>\n  <\/a>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>La ventilazione nelle aree comuni e nelle scale interne di un edificio e la sua importanza per l&#8217;abitabilit\u00e0 e la sicurezza dell&#8217;edificio.<\/p>\n","protected":false},"author":10,"featured_media":5070,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[3],"tags":[],"class_list":["post-5069","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-sostenibilita-ed-efficienza-energetica"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.1 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Ventilazione e protezione antincendio delle aree comuni - S&amp;P<\/title>\n<meta name=\"description\" content=\"La ventilazione nelle aree comuni e nelle scale interne di un edificio e la sua importanza per l&#039;abitabilit\u00e0 e la sicurezza dell&#039;edificio.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.solerpalau.com\/blog\/it-it\/ventilazione-delle-aree-comuni-e-dei-vani-scala-e-protezione-antincendio\/\" \/>\n<meta property=\"og:locale\" content=\"it_IT\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Ventilazione e protezione antincendio delle aree comuni - S&amp;P\" \/>\n<meta property=\"og:description\" content=\"La ventilazione nelle aree comuni e nelle scale interne di un edificio e la sua importanza per l&#039;abitabilit\u00e0 e la sicurezza dell&#039;edificio.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.solerpalau.com\/blog\/it-it\/ventilazione-delle-aree-comuni-e-dei-vani-scala-e-protezione-antincendio\/\" \/>\n<meta property=\"og:site_name\" content=\"S&amp;P Sistemi di ventilazione\" \/>\n<meta property=\"article:published_time\" content=\"2024-07-11T13:48:50+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-12-03T15:28:23+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.solerpalau.com\/blog\/it-it\/wp-content\/uploads\/sites\/4\/2024\/07\/ventilazione-nelle-aree-comuni-e-nelle-scale_-SP.png\" \/>\n\t<meta property=\"og:image:width\" content=\"960\" \/>\n\t<meta property=\"og:image:height\" content=\"636\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"S&amp;P\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Scritto da\" \/>\n\t<meta name=\"twitter:data1\" content=\"S&amp;P\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tempo di lettura stimato\" \/>\n\t<meta name=\"twitter:data2\" content=\"6 minuti\" \/>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Ventilazione e protezione antincendio delle aree comuni - S&P","description":"La ventilazione nelle aree comuni e nelle scale interne di un edificio e la sua importanza per l'abitabilit\u00e0 e la sicurezza dell'edificio.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.solerpalau.com\/blog\/it-it\/ventilazione-delle-aree-comuni-e-dei-vani-scala-e-protezione-antincendio\/","og_locale":"it_IT","og_type":"article","og_title":"Ventilazione e protezione antincendio delle aree comuni - S&P","og_description":"La ventilazione nelle aree comuni e nelle scale interne di un edificio e la sua importanza per l'abitabilit\u00e0 e la sicurezza dell'edificio.","og_url":"https:\/\/www.solerpalau.com\/blog\/it-it\/ventilazione-delle-aree-comuni-e-dei-vani-scala-e-protezione-antincendio\/","og_site_name":"S&amp;P Sistemi di ventilazione","article_published_time":"2024-07-11T13:48:50+00:00","article_modified_time":"2025-12-03T15:28:23+00:00","og_image":[{"width":960,"height":636,"url":"https:\/\/www.solerpalau.com\/blog\/it-it\/wp-content\/uploads\/sites\/4\/2024\/07\/ventilazione-nelle-aree-comuni-e-nelle-scale_-SP.png","type":"image\/png"}],"author":"S&amp;P","twitter_card":"summary_large_image","twitter_misc":{"Scritto da":"S&amp;P","Tempo di lettura stimato":"6 minuti"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.solerpalau.com\/blog\/it-it\/ventilazione-delle-aree-comuni-e-dei-vani-scala-e-protezione-antincendio\/","url":"https:\/\/www.solerpalau.com\/blog\/it-it\/ventilazione-delle-aree-comuni-e-dei-vani-scala-e-protezione-antincendio\/","name":"Ventilazione e protezione antincendio delle aree comuni - S&P","isPartOf":{"@id":"https:\/\/www.solerpalau.com\/blog\/it-it\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.solerpalau.com\/blog\/it-it\/ventilazione-delle-aree-comuni-e-dei-vani-scala-e-protezione-antincendio\/#primaryimage"},"image":{"@id":"https:\/\/www.solerpalau.com\/blog\/it-it\/ventilazione-delle-aree-comuni-e-dei-vani-scala-e-protezione-antincendio\/#primaryimage"},"thumbnailUrl":"https:\/\/www.solerpalau.com\/blog\/it-it\/wp-content\/uploads\/sites\/4\/2024\/07\/ventilazione-nelle-aree-comuni-e-nelle-scale_-SP.png","datePublished":"2024-07-11T13:48:50+00:00","dateModified":"2025-12-03T15:28:23+00:00","author":{"@id":"https:\/\/www.solerpalau.com\/blog\/it-it\/#\/schema\/person\/a649fcc0fccdca5446ea2bc371ad5cb9"},"description":"La ventilazione nelle aree comuni e nelle scale interne di un edificio e la sua importanza per l'abitabilit\u00e0 e la sicurezza dell'edificio.","breadcrumb":{"@id":"https:\/\/www.solerpalau.com\/blog\/it-it\/ventilazione-delle-aree-comuni-e-dei-vani-scala-e-protezione-antincendio\/#breadcrumb"},"inLanguage":"it-IT","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.solerpalau.com\/blog\/it-it\/ventilazione-delle-aree-comuni-e-dei-vani-scala-e-protezione-antincendio\/"]}]},{"@type":"ImageObject","inLanguage":"it-IT","@id":"https:\/\/www.solerpalau.com\/blog\/it-it\/ventilazione-delle-aree-comuni-e-dei-vani-scala-e-protezione-antincendio\/#primaryimage","url":"https:\/\/www.solerpalau.com\/blog\/it-it\/wp-content\/uploads\/sites\/4\/2024\/07\/ventilazione-nelle-aree-comuni-e-nelle-scale_-SP.png","contentUrl":"https:\/\/www.solerpalau.com\/blog\/it-it\/wp-content\/uploads\/sites\/4\/2024\/07\/ventilazione-nelle-aree-comuni-e-nelle-scale_-SP.png","width":960,"height":636,"caption":"ventilazione nelle aree comuni e nelle scale_ S&P"},{"@type":"BreadcrumbList","@id":"https:\/\/www.solerpalau.com\/blog\/it-it\/ventilazione-delle-aree-comuni-e-dei-vani-scala-e-protezione-antincendio\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.solerpalau.com\/blog\/it-it\/"},{"@type":"ListItem","position":2,"name":"Ventilazione delle aree comuni e dei vani scala e protezione antincendio"}]},{"@type":"WebSite","@id":"https:\/\/www.solerpalau.com\/blog\/it-it\/#website","url":"https:\/\/www.solerpalau.com\/blog\/it-it\/","name":"S&amp;P Sistemi di ventilazione","description":"Il blog della ventilazione efficiente","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.solerpalau.com\/blog\/it-it\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"it-IT"},{"@type":"Person","@id":"https:\/\/www.solerpalau.com\/blog\/it-it\/#\/schema\/person\/a649fcc0fccdca5446ea2bc371ad5cb9","name":"S&amp;P","image":{"@type":"ImageObject","inLanguage":"it-IT","@id":"https:\/\/www.solerpalau.com\/blog\/it-it\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/994644236667321375ba4d21a34a002e2bcfd7b33a114caa4c9dc488ece6c970?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/994644236667321375ba4d21a34a002e2bcfd7b33a114caa4c9dc488ece6c970?s=96&d=mm&r=g","caption":"S&amp;P"},"url":"https:\/\/www.solerpalau.com\/blog\/it-it\/author\/binaria\/"}]}},"reading_time":"<span class=\"span-reading-time rt-reading-time\"><span class=\"rt-label rt-prefix\"><\/span> <span class=\"rt-time\"> 4<\/span> <span class=\"rt-label rt-postfix\"> min. di lettura<\/span><\/span>","_links":{"self":[{"href":"https:\/\/www.solerpalau.com\/blog\/it-it\/wp-json\/wp\/v2\/posts\/5069","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.solerpalau.com\/blog\/it-it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.solerpalau.com\/blog\/it-it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.solerpalau.com\/blog\/it-it\/wp-json\/wp\/v2\/users\/10"}],"replies":[{"embeddable":true,"href":"https:\/\/www.solerpalau.com\/blog\/it-it\/wp-json\/wp\/v2\/comments?post=5069"}],"version-history":[{"count":4,"href":"https:\/\/www.solerpalau.com\/blog\/it-it\/wp-json\/wp\/v2\/posts\/5069\/revisions"}],"predecessor-version":[{"id":5678,"href":"https:\/\/www.solerpalau.com\/blog\/it-it\/wp-json\/wp\/v2\/posts\/5069\/revisions\/5678"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.solerpalau.com\/blog\/it-it\/wp-json\/wp\/v2\/media\/5070"}],"wp:attachment":[{"href":"https:\/\/www.solerpalau.com\/blog\/it-it\/wp-json\/wp\/v2\/media?parent=5069"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.solerpalau.com\/blog\/it-it\/wp-json\/wp\/v2\/categories?post=5069"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.solerpalau.com\/blog\/it-it\/wp-json\/wp\/v2\/tags?post=5069"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}