{"id":1181,"date":"2017-07-26T08:00:43","date_gmt":"2017-07-26T06:00:43","guid":{"rendered":"https:\/\/www.solerpalau.com\/blog\/?p=1181"},"modified":"2019-04-15T10:47:55","modified_gmt":"2019-04-15T08:47:55","slug":"la-directiva-erp-implicaciones-unidades-ventilacion","status":"publish","type":"post","link":"https:\/\/www.solerpalau.com\/blog\/2017\/07\/26\/la-directiva-erp-implicaciones-unidades-ventilacion\/","title":{"rendered":"La Directiva ErP y sus implicaciones en unidades de ventilaci\u00f3n"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_76 counter-hierarchy ez-toc-counter ez-toc-custom ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Table of Contents<\/p>\n<span class=\"ez-toc-title-toggle\"><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.solerpalau.com\/blog\/2017\/07\/26\/la-directiva-erp-implicaciones-unidades-ventilacion\/#Frenar_el_cambio_climatico\" >Frenar el cambio clim\u00e1tico<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.solerpalau.com\/blog\/2017\/07\/26\/la-directiva-erp-implicaciones-unidades-ventilacion\/#UVR_%E2%80%93_Unidades_de_ventilacion_residenciales\" >UVR \u2013 Unidades de ventilaci\u00f3n residenciales<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.solerpalau.com\/blog\/2017\/07\/26\/la-directiva-erp-implicaciones-unidades-ventilacion\/#UVNR_%E2%80%93_Unidades_de_Ventilacion_No_residenciales\" >UVNR \u2013 Unidades de Ventilaci\u00f3n No residenciales<\/a><\/li><\/ul><\/nav><\/div>\n<span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">Reading Time: <\/span> <span class=\"rt-time\"> 3<\/span> <span class=\"rt-label rt-postfix\">minutes<\/span><\/span><p>La Directiva de Ecodise\u00f1o 2009\/125\/EC tambi\u00e9n llamada Directiva ErP (Energy related products) dispone un marco para el establecimiento de los requisitos comunitarios de dise\u00f1o ecol\u00f3gico aplicables a los productos relacionados con la energ\u00eda.<\/p>\n<p><!--more--><\/p>\n<p>Esta es una Directiva de un alcance extraordinario pues afecta no s\u00f3lo a los equipos que activamente consumen energ\u00eda, incluye tambi\u00e9n los pasivos, que no consumen directamente energ\u00eda pero inciden en su consumo. As\u00ed por ejemplo, en el campo de la ventilaci\u00f3n los <a href=\"https:\/\/www.solerpalau.com\/blog\/filtros-sistemas-ventilacion-contaminantes-primarios\/\">filtros<\/a> se ven afectados por esta Directiva, ya que si bien no consumen energ\u00eda, la p\u00e9rdida de carga que causan en el sistema de ventilaci\u00f3n s\u00ed ocasiona mayor consumo de los ventiladores.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Frenar_el_cambio_climatico\"><\/span>Frenar el cambio clim\u00e1tico<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>En el trasfondo de esta Directiva, que rige exclusivamente en el \u00e1mbito de la Comunidad Europea, est\u00e1 la lucha mundial por frenar el cambio clim\u00e1tico, o sea por reducir las emisiones de CO2 producto de la combusti\u00f3n de combustibles f\u00f3siles. Este prop\u00f3sito de reducci\u00f3n de emisiones ya se estableci\u00f3 en el protocolo de Kyoto de 1997, luego la Uni\u00f3n Europea, en 2007 cre\u00f3 la f\u00f3rmula-objetivo 20\/20\/20 que establece una reducci\u00f3n de las emisiones de un 20% (en relaci\u00f3n a las de 1990), la proporci\u00f3n de energ\u00edas renovables en la combinaci\u00f3n de las diferentes fuentes de energ\u00eda debe aumentar hasta el 20% al igual que la eficiencia de los equipos debe aumentar un 20%, todo ello en el horizonte del 2020.<\/p>\n<p>Esta Directiva establece unos apartados (en ingl\u00e9s Lot) para los diferentes tipos de producto. En el caso de la ventilaci\u00f3n, la Directiva distingue entre los ventiladores que son aparatos con un motor, una h\u00e9lice y una embocadura, que los regula en el Lot 11 y las Unidades de Ventilaci\u00f3n (UV) que son m\u00e1quinas que adem\u00e1s de un ventilador incorporan otros elementos tales como una caja, filtros, etc. que los regula en el Lot 6.<\/p>\n<p>Desde el punto de vista del timing de aplicaci\u00f3n, para los ventiladores se inici\u00f3 en enero de 2013, luego en 2015 se aumentaron las exigencias en cuanto a los niveles m\u00ednimos de eficiencia de los equipos y en el futuro se ir\u00e1n incrementando estas exigencias de acuerdo con la evoluci\u00f3n y las posibilidades tecnol\u00f3gicas de cada momento. En cuanto a las UV, su regulaci\u00f3n se inici\u00f3 en enero de 2016.<\/p>\n<p>Esta Directiva clasifica las Unidades de Ventilaci\u00f3n (UV) en Residenciales (UVR) y No Residenciales (UVNR).<\/p>\n<h2><span class=\"ez-toc-section\" id=\"UVR_%E2%80%93_Unidades_de_ventilacion_residenciales\"><\/span>UVR \u2013 Unidades de ventilaci\u00f3n residenciales<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Se consideran UVR las unidades que mueven caudales menores de 250 m3\/h y las que est\u00e1n entre 250 y 1000 m3\/h pueden serlo o no seg\u00fan defina el fabricante el uso al que van destinadas. Las UVR cuyo consumo sea inferior a 30 w. est\u00e1n exentas de cumplir con los requisitos de la ErP.<\/p>\n<p>La Directiva establece para las UVR unas clases de eficiencia a las que le asigna una letra y un color que deben constar en una etiqueta (ver imagen adjunta) que se pegar\u00e1 al equipo.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-1182\" style=\"height: 432px;\" src=\"https:\/\/www.solerpalau.com\/blog\/wp-content\/uploads\/2017\/07\/etiqueta-directiva-erp-sp.png\" alt=\"Etiqueta Directiva ErP S&amp;P\" width=\"260\" height=\"432\" srcset=\"https:\/\/www.solerpalau.com\/blog\/wp-content\/uploads\/2017\/07\/etiqueta-directiva-erp-sp.png 776w, https:\/\/www.solerpalau.com\/blog\/wp-content\/uploads\/2017\/07\/etiqueta-directiva-erp-sp-600x996.png 600w, https:\/\/www.solerpalau.com\/blog\/wp-content\/uploads\/2017\/07\/etiqueta-directiva-erp-sp-768x1275.png 768w\" sizes=\"auto, (max-width: 260px) 100vw, 260px\" \/><\/p>\n<p>La A (color verde) corresponde a los equipos m\u00e1s eficientes y la G (color rojo) a los menos eficientes. Con el tiempo no se permitir\u00e1 la comercializaci\u00f3n de los equipos calificados con las letras correspondientes a las menores eficiencias (E,F,G).<\/p>\n<h2><span class=\"ez-toc-section\" id=\"UVNR_%E2%80%93_Unidades_de_Ventilacion_No_residenciales\"><\/span>UVNR \u2013 Unidades de Ventilaci\u00f3n No residenciales<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Las Unidades de Ventilaci\u00f3n no residenciales que son todas las de m\u00e1s de 1000 m3\/h o las de m\u00e1s de 250 m3\/h que as\u00ed lo especifique el fabricante, son tratadas de distinta forma por la Directiva. \u00c9sta establece para las UVNR una f\u00f3rmula para calcular su eficiencia que debe de estar por encima de los niveles requeridos por la Directiva, si los supera es apta para su comercializaci\u00f3n y si no los supera se debe retirar del mercado, pero en este caso no hay ni letra ni color.<\/p>\n<p>La Directiva ErP constituye un gran paso en la mejora de la eficiencia de los ventiladores y de las Unidades de Ventilaci\u00f3n, se estima que en su entrada en vigor, m\u00e1s de un tercio de los ventiladores debieron de ser modificados para mejorar su eficiencia o retirados del mercado, evidentemente conforme la Directiva vaya incrementando su exigencia, los equipos deber\u00e1n ser cada vez m\u00e1s eficientes.<\/p>\n<p><!--HubSpot Call-to-Action Code --><span class=\"hs-cta-wrapper\" id=\"hs-cta-wrapper-9d59c54a-b24e-40c7-b211-905d19224a91\"><span class=\"hs-cta-node hs-cta-9d59c54a-b24e-40c7-b211-905d19224a91\" id=\"hs-cta-9d59c54a-b24e-40c7-b211-905d19224a91\"><!--[if lte IE 8]>\n\n<div id=\"hs-cta-ie-element\"><\/div>\n\n<![endif]--><a href=\"https:\/\/cta-redirect.hubspot.com\/cta\/redirect\/2009592\/9d59c54a-b24e-40c7-b211-905d19224a91\"  target=\"_blank\" ><img decoding=\"async\" class=\"hs-cta-img\" id=\"hs-cta-img-9d59c54a-b24e-40c7-b211-905d19224a91\" style=\"border-width:0px;\" src=\"https:\/\/no-cache.hubspot.com\/cta\/default\/2009592\/9d59c54a-b24e-40c7-b211-905d19224a91.png\"  alt=\"Directiva ERP\"\/><\/a><\/span><script charset=\"utf-8\" src=\"https:\/\/js.hscta.net\/cta\/current.js\"><\/script><script type=\"text\/javascript\"> hbspt.cta.load(2009592, '9d59c54a-b24e-40c7-b211-905d19224a91', {}); <\/script><\/span><!-- end HubSpot Call-to-Action Code --><\/p>\n","protected":false},"excerpt":{"rendered":"<p><span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">Reading Time: <\/span> <span class=\"rt-time\"> 3<\/span> <span class=\"rt-label rt-postfix\">minutes<\/span><\/span>La Directiva de Ecodise\u00f1o 2009\/125\/EC tambi\u00e9n llamada Directiva ErP (Energy related products) dispone un marco para el establecimiento de los requisitos comunitarios de dise\u00f1o ecol\u00f3gico aplicables a los productos relacionados con la energ\u00eda.<\/p>\n","protected":false},"author":10,"featured_media":1183,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[5],"tags":[],"class_list":["post-1181","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-normativas-de-ventilacion-de-espacios"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.1 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>La Directiva ErP y sus implicaciones en unidades de ventilaci\u00f3n<\/title>\n<meta name=\"description\" content=\"La Directiva ErP afecta a los filtros de los sistemas de ventilaci\u00f3n ya que la p\u00e9rdida de carga que causan ocasiona un mayor consumo.\" \/>\n<meta name=\"robots\" content=\"noindex, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"La Directiva ErP y sus implicaciones en unidades de ventilaci\u00f3n\" \/>\n<meta property=\"og:description\" content=\"La Directiva ErP afecta a los filtros de los sistemas de ventilaci\u00f3n ya que la p\u00e9rdida de carga que causan ocasiona un mayor consumo.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.solerpalau.com\/es-es\/directiva-erp\/\" \/>\n<meta property=\"og:site_name\" content=\"S&amp;P \/blog no visible\" \/>\n<meta property=\"article:published_time\" content=\"2017-07-26T06:00:43+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2019-04-15T08:47:55+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.solerpalau.com\/blog\/wp-content\/uploads\/2017\/07\/directiva-erp.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"683\" \/>\n\t<meta property=\"og:image:height\" content=\"512\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"S&amp;P\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t<meta name=\"twitter:data1\" content=\"S&amp;P\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tiempo de lectura\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutos\" \/>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"La Directiva ErP y sus implicaciones en unidades de ventilaci\u00f3n","description":"La Directiva ErP afecta a los filtros de los sistemas de ventilaci\u00f3n ya que la p\u00e9rdida de carga que causan ocasiona un mayor consumo.","robots":{"index":"noindex","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"og_locale":"es_ES","og_type":"article","og_title":"La Directiva ErP y sus implicaciones en unidades de ventilaci\u00f3n","og_description":"La Directiva ErP afecta a los filtros de los sistemas de ventilaci\u00f3n ya que la p\u00e9rdida de carga que causan ocasiona un mayor consumo.","og_url":"https:\/\/www.solerpalau.com\/es-es\/directiva-erp\/","og_site_name":"S&amp;P \/blog no visible","article_published_time":"2017-07-26T06:00:43+00:00","article_modified_time":"2019-04-15T08:47:55+00:00","og_image":[{"width":683,"height":512,"url":"https:\/\/www.solerpalau.com\/blog\/wp-content\/uploads\/2017\/07\/directiva-erp.jpg","type":"image\/jpeg"}],"author":"S&amp;P","twitter_card":"summary_large_image","twitter_misc":{"Escrito por":"S&amp;P","Tiempo de lectura":"4 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.solerpalau.com\/blog\/2017\/07\/26\/la-directiva-erp-implicaciones-unidades-ventilacion\/","url":"https:\/\/www.solerpalau.com\/es-es\/directiva-erp\/","name":"La Directiva ErP y sus implicaciones en unidades de ventilaci\u00f3n","isPartOf":{"@id":"https:\/\/www.solerpalau.com\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.solerpalau.com\/es-es\/directiva-erp\/#primaryimage"},"image":{"@id":"https:\/\/www.solerpalau.com\/es-es\/directiva-erp\/#primaryimage"},"thumbnailUrl":"https:\/\/www.solerpalau.com\/blog\/wp-content\/uploads\/2017\/07\/directiva-erp.jpg","datePublished":"2017-07-26T06:00:43+00:00","dateModified":"2019-04-15T08:47:55+00:00","author":{"@id":"https:\/\/www.solerpalau.com\/blog\/#\/schema\/person\/a649fcc0fccdca5446ea2bc371ad5cb9"},"description":"La Directiva ErP afecta a los filtros de los sistemas de ventilaci\u00f3n ya que la p\u00e9rdida de carga que causan ocasiona un mayor consumo.","breadcrumb":{"@id":"https:\/\/www.solerpalau.com\/es-es\/directiva-erp\/#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.solerpalau.com\/es-es\/directiva-erp\/"]}]},{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/www.solerpalau.com\/es-es\/directiva-erp\/#primaryimage","url":"https:\/\/www.solerpalau.com\/blog\/wp-content\/uploads\/2017\/07\/directiva-erp.jpg","contentUrl":"https:\/\/www.solerpalau.com\/blog\/wp-content\/uploads\/2017\/07\/directiva-erp.jpg","width":683,"height":512,"caption":"Directiva ErP S&P"},{"@type":"BreadcrumbList","@id":"https:\/\/www.solerpalau.com\/es-es\/directiva-erp\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Portada","item":"https:\/\/www.solerpalau.com\/blog\/"},{"@type":"ListItem","position":2,"name":"La Directiva ErP y sus implicaciones en unidades de ventilaci\u00f3n"}]},{"@type":"WebSite","@id":"https:\/\/www.solerpalau.com\/blog\/#website","url":"https:\/\/www.solerpalau.com\/blog\/","name":"S&amp;P \/blog no visible","description":"El Blog de ventilaci\u00f3n eficiente para una mejor calidad del aire","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.solerpalau.com\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es"},{"@type":"Person","@id":"https:\/\/www.solerpalau.com\/blog\/#\/schema\/person\/a649fcc0fccdca5446ea2bc371ad5cb9","name":"S&amp;P","image":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/www.solerpalau.com\/blog\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/994644236667321375ba4d21a34a002e2bcfd7b33a114caa4c9dc488ece6c970?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/994644236667321375ba4d21a34a002e2bcfd7b33a114caa4c9dc488ece6c970?s=96&d=mm&r=g","caption":"S&amp;P"},"url":"https:\/\/www.solerpalau.com\/blog\/author\/binaria\/"}]}},"reading_time":"<span class=\"span-reading-time rt-reading-time\"><span class=\"rt-label rt-prefix\"><\/span> <span class=\"rt-time\"> 3<\/span> <span class=\"rt-label rt-postfix\"> min. de lectura<\/span><\/span>","_links":{"self":[{"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/posts\/1181","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/users\/10"}],"replies":[{"embeddable":true,"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/comments?post=1181"}],"version-history":[{"count":7,"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/posts\/1181\/revisions"}],"predecessor-version":[{"id":1185,"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/posts\/1181\/revisions\/1185"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/media\/1183"}],"wp:attachment":[{"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/media?parent=1181"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/categories?post=1181"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/tags?post=1181"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}