{"id":1243,"date":"2017-08-21T13:05:36","date_gmt":"2017-08-21T11:05:36","guid":{"rendered":"https:\/\/www.solerpalau.com\/blog\/?p=1243"},"modified":"2019-04-15T10:47:53","modified_gmt":"2019-04-15T08:47:53","slug":"clasificacion-filtros-une-en-13779","status":"publish","type":"post","link":"https:\/\/www.solerpalau.com\/blog\/2017\/08\/21\/clasificacion-filtros-une-en-13779\/","title":{"rendered":"Clasificaci\u00f3n de filtros seg\u00fan la UNE-EN 13779"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_76 counter-hierarchy ez-toc-counter ez-toc-custom ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Table of Contents<\/p>\n<span class=\"ez-toc-title-toggle\"><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.solerpalau.com\/blog\/2017\/08\/21\/clasificacion-filtros-une-en-13779\/#%C2%BFCuales_son_las_normativas_que_afectan_a_la_utilizacion_de_filtros\" >\u00bfCu\u00e1les son las normativas que afectan a la utilizaci\u00f3n de filtros?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.solerpalau.com\/blog\/2017\/08\/21\/clasificacion-filtros-une-en-13779\/#Clasificacion_segun_la_UNE-EN_13779_2008_del_aire_de_extraccion_y_de_expulsion\" >Clasificaci\u00f3n seg\u00fan la UNE-EN 13779:2008 del aire de extracci\u00f3n y de expulsi\u00f3n<\/a><\/li><\/ul><\/nav><\/div>\n<span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">Reading Time: <\/span> <span class=\"rt-time\"> 4<\/span> <span class=\"rt-label rt-postfix\">minutes<\/span><\/span><p>La norma UNE-EN 13779:2008 define las exigencias de los sistemas de ventilaci\u00f3n y de acondicionamientos de edificios no residenciales. Un sistema de ventilaci\u00f3n mec\u00e1nica adecuado permitir\u00e1 garantizar la salubridad del aire interior.<\/p>\n<p><!--more--><\/p>\n<h2><span class=\"ez-toc-section\" id=\"%C2%BFCuales_son_las_normativas_que_afectan_a_la_utilizacion_de_filtros\"><\/span>\u00bfCu\u00e1les son las normativas que afectan a la utilizaci\u00f3n de filtros?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><span style=\"font-weight: 400;\">La norma UNE-EN 13779:2008 define las exigencias de los<a href=\"https:\/\/www.solerpalau.com\/blog\/todo-lo-que-debes-saber-sobre-los-sistemas-ventilacion\/\"> sistemas de ventilaci\u00f3n<\/a> y de acondicionamientos de edificios no residenciales. Un sistema de ventilaci\u00f3n mec\u00e1nica adecuado permitir\u00e1 garantizar la salubridad del aire interior.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">La utilizaci\u00f3n de filtros en la entrada del aire exterior ayuda a mejorar la calidad del aire del interior. Para ello, en la UNE-EN 13779:2008 se establecen unos requisitos de filtraci\u00f3n m\u00ednima que son funci\u00f3n de la calidad del aire interior deseada (ETA\/EHA) y del tipo de aire exterior (ODA). Por lo tanto, previamente a la selecci\u00f3n de las etapas de filtraci\u00f3n ser\u00e1 necesario categorizar el tipo de aire interior deseado y de aire exterior existente en el lugar de ubicaci\u00f3n del edificio.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Un sobredimensionado de las secciones de filtraci\u00f3n conllevar\u00e1 la optimizaci\u00f3n energ\u00e9tica de la instalaci\u00f3n as\u00ed como la reducci\u00f3n del consumo de los ventiladores. En la selecci\u00f3n de los filtros se deber\u00e1n considerar las particularidades de cada aplicaci\u00f3n (tiempo de funcionamiento de la instalaci\u00f3n, concentraci\u00f3n de polvo en el ambiente, existencia de fuentes locales de contaminaci\u00f3n, etc).<\/span><\/p>\n<h3>Uso de prefiltros<\/h3>\n<p><span style=\"font-weight: 400;\">Adem\u00e1s de los filtros, puede ser recomendable emplear prefiltros en la entrada del aire exterior y de retorno para mantener limpios los componentes de<\/span><a href=\"https:\/\/www.solerpalau.com\/blog\/unidades-de-tratamiento-de-aire\/\"><span style=\"font-weight: 400;\"> las Unidades de Tratamiento de Aire<\/span><\/a><span style=\"font-weight: 400;\"> (UTA), al mismo tiempo, se conseguir\u00e1 una mejora de la eficiencia del sistema de ventilaci\u00f3n y un aumento de la vida \u00fatil de los filtros finales.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">En todas las secciones de filtraci\u00f3n, salvo en las situadas en tomas de aire exterior, se garantizar\u00e1n las condiciones de funcionamiento en seco; por ello la humedad relativa del aire deber\u00e1 ser siempre inferior al 90%.<\/span><\/p>\n<h2><span class=\"ez-toc-section\" id=\"Clasificacion_segun_la_UNE-EN_13779_2008_del_aire_de_extraccion_y_de_expulsion\"><\/span><b>Clasificaci\u00f3n seg\u00fan la UNE-EN 13779:2008 del aire de extracci\u00f3n y de expulsi\u00f3n<\/b><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><span style=\"font-weight: 400;\">En funci\u00f3n del uso del edificio o local, el aire de extracci\u00f3n (ETA) y el aire de expulsi\u00f3n (EHA) se clasifica en las siguientes categor\u00edas:<\/span><\/p>\n<ul>\n<li><span style=\"font-weight: 400;\">Aire de extracci\u00f3n con un nivel de contaminaci\u00f3n bajo (ETA 1\/ EHA 1): Define al aire procedente de los locales y oficinas en los que las principales fuentes de emisi\u00f3n son las estructuras y los materiales del edificio, y tambi\u00e9n el aire procedente de los locales ocupados en los que las principales fuentes de emisi\u00f3n son debidas al metabolismo humano, las estructuras y los materiales del edificio. Se excluyen los locales en los que est\u00e1 permitido fumar ya que este aire est\u00e1 prohibido ser retornado al local.<\/span><\/li>\n<li><span style=\"font-weight: 400;\">Aire de extracci\u00f3n con un nivel de contaminaci\u00f3n moderado (ETA 2\/EHA 2): Define al aire procedente de los locales ocupados y que contiene m\u00e1s impurezas que el de la categor\u00eda ETA 1\/ EHA 1 procedente de las mismas fuentes, pero tambi\u00e9n de las mismas actividades humanas. En este apartado se incluyen los locales en los que est\u00e1 permitido fumar. Este aire de categor\u00eda ETA 2 puede ser empleado \u00fanicamente como aire de transferencia de un local hacia locales de servicio, aseos o garajes.<\/span><\/li>\n<li><span style=\"font-weight: 400;\">Aire de extracci\u00f3n con un nivel de contaminaci\u00f3n alto (ETA 3\/EHA 3): Define al aire procedente de los locales en los que se realizan procesos que generan elevada humedad, olores, productos qu\u00edmicos, etc. reduciendo sustancialmente la calidad del aire interior.<\/span><\/li>\n<li><span style=\"font-weight: 400;\">Aire de extracci\u00f3n con un nivel de contaminaci\u00f3n muy alta (ETA 4\/ EHA 4): Define al aire que contiene olores e impurezas en concentraciones significativamente superiores a las permitidas en el aire interior de las zonas ocupadas.<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">Seg\u00fan la normativa, el aire de las categor\u00edas ETA 3 y ETA 4 no puede ser empleado como aire de recirculaci\u00f3n o de transferencia hacia otros locales o zonas del edificio. Adem\u00e1s, la expulsi\u00f3n hacia el exterior del aire de estas dos \u00faltimas categor\u00edas no puede ser com\u00fan a la expulsi\u00f3n del aire de las categor\u00edas ETA 1 y ETA 2. De esta forma se evita la posibilidad de contaminaci\u00f3n cruzada.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">La adaptaci\u00f3n de la norma UNE-EN 13779:2008 en el RITE establece las clases de filtraci\u00f3n m\u00ednimas que se deben emplear en funci\u00f3n de la calidad del aire exterior y los requerimientos que debe cumplir el aire interior. Todo aire exterior que se introduzca mec\u00e1nicamente a trav\u00e9s de los sistemas de ventilaci\u00f3n deber\u00e1 estar correctamente filtrado.<\/span><\/p>\n<h3>Calidad del aire interior: cu\u00e1les son los distintos niveles<\/h3>\n<p><span style=\"font-weight: 400;\"><a href=\"https:\/\/www.solerpalau.com\/blog\/rite-ventilacion-calidad-aire-interior\/\">El RITE<\/a> determina la calidad del aire interior en cuatro niveles (IDA 1, IDA 2, IDA 3, IDA 4) seg\u00fan su concentraci\u00f3n de CO<\/span><span style=\"font-weight: 400;\">2<\/span><span style=\"font-weight: 400;\"> (en partes por mill\u00f3n en volumen) por encima de la concentraci\u00f3n en el aire exterior y seg\u00fan el informe CR 1752 (m\u00e9todo olfativo). Y clasifica tambi\u00e9n la calidad del aire exterior (ODA) de acuerdo con los siguientes niveles:<\/span><\/p>\n<ul>\n<li><span style=\"font-weight: 400;\"> \u00a0\u00a0\u00a0\u00a0<\/span><span style=\"font-weight: 400;\">ODA 1: Aire puro que se ensucia s\u00f3lo temporalmente (por ejemplo polen).<\/span><\/li>\n<li><span style=\"font-weight: 400;\"> \u00a0\u00a0\u00a0\u00a0<\/span><span style=\"font-weight: 400;\">ODA 2: Aire con concentraciones altas de part\u00edculas y, o de gases contaminantes.<\/span><\/li>\n<li><span style=\"font-weight: 400;\"> \u00a0\u00a0\u00a0\u00a0<\/span><span style=\"font-weight: 400;\">ODA 3: Aire con concentraciones muy altas de gases contaminantes (ODA 3G) y, o de part\u00edculas (ODA 3P).<\/span><\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p><span style=\"font-weight: 400;\">Por consiguiente, en funci\u00f3n de la categor\u00eda del aire exterior (ODA) y del aire interior requerida (IDA), se establecen los siguientes tipos de filtraci\u00f3n m\u00ednimos para garantizar la calidad del aire:<\/span><\/p>\n<table style=\"height: 224px;\" width=\"714\">\n<tbody>\n<tr>\n<td><\/td>\n<td style=\"text-align: center;\"><strong>IDA 1<\/strong><\/td>\n<td style=\"text-align: center;\"><strong>IDA 2<\/strong><\/td>\n<td style=\"text-align: center;\"><strong>IDA 3<\/strong><\/td>\n<td style=\"text-align: center;\"><strong>IDA 4<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>ODA 1<\/strong><\/td>\n<td style=\"text-align: center;\"><span style=\"font-weight: 400;\">F9<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-weight: 400;\">F8<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-weight: 400;\">F7<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-weight: 400;\">F5<\/span><\/td>\n<\/tr>\n<tr>\n<td><strong>ODA 2<\/strong><\/td>\n<td style=\"text-align: center;\"><span style=\"font-weight: 400;\">F7+F9<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-weight: 400;\">F6+F8<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-weight: 400;\">F5+F7<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-weight: 400;\">F5+F6<\/span><\/td>\n<\/tr>\n<tr>\n<td><strong>ODA 3<\/strong><\/td>\n<td style=\"text-align: center;\"><span style=\"font-weight: 400;\">F7+ GF(*)+F9<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-weight: 400;\">F7+GF+F9<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-weight: 400;\">F5+F7<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-weight: 400;\">F5+F6<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><span style=\"font-weight: 400;\">Fuente:<\/span><a href=\"http:\/\/www.minetad.gob.es\/energia\/desarrollo\/EficienciaEnergetica\/RITE\/Reglamento\/RDecreto-1027-2007-Consolidado-9092013.pdf\"> <span style=\"font-weight: 400;\">Real Decreto 1027\/2007<\/span><\/a><\/p>\n<p><span style=\"font-weight: 400;\">En aquellos casos en los que el aire est\u00e1 m\u00e1s contaminado (como por ejemplo el ODA 3\/IDA 1 y 2) se deber\u00e1n instalar un filtro de gas (GF) y\/o filtro qu\u00edmico o f\u00edsico-qu\u00edmico entre las dos etapas de filtraci\u00f3n. Tambi\u00e9n se recomienda emplear prefiltros para mantener limpios los componentes de los sistemas de ventilaci\u00f3n.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Mediante la instalaci\u00f3n de estos filtros, se pueden reducir los niveles part\u00edculas contaminantes y mejorar la calidad del aire que respiran las personas.<\/span><\/p>\n<p><span data-sheets-value=\"{&quot;1&quot;:2,&quot;2&quot;:&quot;[cta_hubspot id=1086]&quot;}\" data-sheets-userformat=\"{&quot;2&quot;:513,&quot;3&quot;:[null,0],&quot;12&quot;:0}\">[cta_hubspot id=1086]<\/span><\/p>\n","protected":false},"excerpt":{"rendered":"<p><span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">Reading Time: <\/span> <span class=\"rt-time\"> 4<\/span> <span class=\"rt-label rt-postfix\">minutes<\/span><\/span>La norma UNE-EN 13779:2008 define las exigencias de los sistemas de ventilaci\u00f3n y de acondicionamientos de edificios no residenciales. Un sistema de ventilaci\u00f3n mec\u00e1nica adecuado permitir\u00e1 garantizar la salubridad del aire interior.<\/p>\n","protected":false},"author":10,"featured_media":1478,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[7],"tags":[],"class_list":["post-1243","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-efectos-de-la-mala-calidad-del-aire"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.1 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Clasificaci\u00f3n de filtros seg\u00fan la UNE-EN 13779 - S&amp;P \/blog no visible<\/title>\n<meta name=\"robots\" content=\"noindex, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Clasificaci\u00f3n de filtros seg\u00fan la UNE-EN 13779 - S&amp;P \/blog no visible\" \/>\n<meta property=\"og:description\" content=\"Reading Time:  4 minutesLa norma UNE-EN 13779:2008 define las exigencias de los sistemas de ventilaci\u00f3n y de acondicionamientos de edificios no residenciales. Un sistema de ventilaci\u00f3n mec\u00e1nica adecuado permitir\u00e1 garantizar la salubridad del aire interior.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.solerpalau.com\/blog\/2017\/08\/21\/clasificacion-filtros-une-en-13779\/\" \/>\n<meta property=\"og:site_name\" content=\"S&amp;P \/blog no visible\" \/>\n<meta property=\"article:published_time\" content=\"2017-08-21T11:05:36+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2019-04-15T08:47:53+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.solerpalau.com\/blog\/wp-content\/uploads\/2017\/08\/filtros-calidad-aire-une-en-13779-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"683\" \/>\n\t<meta property=\"og:image:height\" content=\"512\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"S&amp;P\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t<meta name=\"twitter:data1\" content=\"S&amp;P\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tiempo de lectura\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minutos\" \/>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Clasificaci\u00f3n de filtros seg\u00fan la UNE-EN 13779 - S&amp;P \/blog no visible","robots":{"index":"noindex","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"og_locale":"es_ES","og_type":"article","og_title":"Clasificaci\u00f3n de filtros seg\u00fan la UNE-EN 13779 - S&amp;P \/blog no visible","og_description":"Reading Time:  4 minutesLa norma UNE-EN 13779:2008 define las exigencias de los sistemas de ventilaci\u00f3n y de acondicionamientos de edificios no residenciales. Un sistema de ventilaci\u00f3n mec\u00e1nica adecuado permitir\u00e1 garantizar la salubridad del aire interior.","og_url":"https:\/\/www.solerpalau.com\/blog\/2017\/08\/21\/clasificacion-filtros-une-en-13779\/","og_site_name":"S&amp;P \/blog no visible","article_published_time":"2017-08-21T11:05:36+00:00","article_modified_time":"2019-04-15T08:47:53+00:00","og_image":[{"width":683,"height":512,"url":"https:\/\/www.solerpalau.com\/blog\/wp-content\/uploads\/2017\/08\/filtros-calidad-aire-une-en-13779-1.jpg","type":"image\/jpeg"}],"author":"S&amp;P","twitter_card":"summary_large_image","twitter_misc":{"Escrito por":"S&amp;P","Tiempo de lectura":"5 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.solerpalau.com\/blog\/2017\/08\/21\/clasificacion-filtros-une-en-13779\/","url":"https:\/\/www.solerpalau.com\/blog\/2017\/08\/21\/clasificacion-filtros-une-en-13779\/","name":"Clasificaci\u00f3n de filtros seg\u00fan la UNE-EN 13779 - S&amp;P \/blog no visible","isPartOf":{"@id":"https:\/\/www.solerpalau.com\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.solerpalau.com\/blog\/2017\/08\/21\/clasificacion-filtros-une-en-13779\/#primaryimage"},"image":{"@id":"https:\/\/www.solerpalau.com\/blog\/2017\/08\/21\/clasificacion-filtros-une-en-13779\/#primaryimage"},"thumbnailUrl":"https:\/\/www.solerpalau.com\/blog\/wp-content\/uploads\/2017\/08\/filtros-calidad-aire-une-en-13779-1.jpg","datePublished":"2017-08-21T11:05:36+00:00","dateModified":"2019-04-15T08:47:53+00:00","author":{"@id":"https:\/\/www.solerpalau.com\/blog\/#\/schema\/person\/a649fcc0fccdca5446ea2bc371ad5cb9"},"breadcrumb":{"@id":"https:\/\/www.solerpalau.com\/blog\/2017\/08\/21\/clasificacion-filtros-une-en-13779\/#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.solerpalau.com\/blog\/2017\/08\/21\/clasificacion-filtros-une-en-13779\/"]}]},{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/www.solerpalau.com\/blog\/2017\/08\/21\/clasificacion-filtros-une-en-13779\/#primaryimage","url":"https:\/\/www.solerpalau.com\/blog\/wp-content\/uploads\/2017\/08\/filtros-calidad-aire-une-en-13779-1.jpg","contentUrl":"https:\/\/www.solerpalau.com\/blog\/wp-content\/uploads\/2017\/08\/filtros-calidad-aire-une-en-13779-1.jpg","width":683,"height":512,"caption":"UNE-EN 13779"},{"@type":"BreadcrumbList","@id":"https:\/\/www.solerpalau.com\/blog\/2017\/08\/21\/clasificacion-filtros-une-en-13779\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Portada","item":"https:\/\/www.solerpalau.com\/blog\/"},{"@type":"ListItem","position":2,"name":"Clasificaci\u00f3n de filtros seg\u00fan la UNE-EN 13779"}]},{"@type":"WebSite","@id":"https:\/\/www.solerpalau.com\/blog\/#website","url":"https:\/\/www.solerpalau.com\/blog\/","name":"S&amp;P \/blog no visible","description":"El Blog de ventilaci\u00f3n eficiente para una mejor calidad del aire","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.solerpalau.com\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es"},{"@type":"Person","@id":"https:\/\/www.solerpalau.com\/blog\/#\/schema\/person\/a649fcc0fccdca5446ea2bc371ad5cb9","name":"S&amp;P","image":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/www.solerpalau.com\/blog\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/994644236667321375ba4d21a34a002e2bcfd7b33a114caa4c9dc488ece6c970?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/994644236667321375ba4d21a34a002e2bcfd7b33a114caa4c9dc488ece6c970?s=96&d=mm&r=g","caption":"S&amp;P"},"url":"https:\/\/www.solerpalau.com\/blog\/author\/binaria\/"}]}},"reading_time":"<span class=\"span-reading-time rt-reading-time\"><span class=\"rt-label rt-prefix\"><\/span> <span class=\"rt-time\"> 4<\/span> <span class=\"rt-label rt-postfix\"> min. de lectura<\/span><\/span>","_links":{"self":[{"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/posts\/1243","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/users\/10"}],"replies":[{"embeddable":true,"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/comments?post=1243"}],"version-history":[{"count":8,"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/posts\/1243\/revisions"}],"predecessor-version":[{"id":1312,"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/posts\/1243\/revisions\/1312"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/media\/1478"}],"wp:attachment":[{"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/media?parent=1243"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/categories?post=1243"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/tags?post=1243"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}