{"id":3815,"date":"2021-08-05T10:08:00","date_gmt":"2021-08-05T08:08:00","guid":{"rendered":"http:\/\/www.solerpalau.com\/es-es\/blog\/?p=3815"},"modified":"2021-08-05T10:08:00","modified_gmt":"2021-08-05T08:08:00","slug":"conceptos-basicos-sobre-normativa-atex-clasificacion-y-tipologia-de-equipos-a-prueba-de-explosion","status":"publish","type":"post","link":"https:\/\/www.solerpalau.com\/blog\/2021\/08\/05\/conceptos-basicos-sobre-normativa-atex-clasificacion-y-tipologia-de-equipos-a-prueba-de-explosion\/","title":{"rendered":"Conceptos b\u00e1sicos sobre normativa ATEX: Clasificaci\u00f3n y tipolog\u00eda de equipos a prueba de explosi\u00f3n"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_76 counter-hierarchy ez-toc-counter ez-toc-custom ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Table of Contents<\/p>\n<span class=\"ez-toc-title-toggle\"><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.solerpalau.com\/blog\/2021\/08\/05\/conceptos-basicos-sobre-normativa-atex-clasificacion-y-tipologia-de-equipos-a-prueba-de-explosion\/#Clasificacion_de_las_zonas_dentro_y_en_el_exterior_del_ventilador\" >Clasificaci\u00f3n de las zonas dentro y en el exterior del ventilador<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.solerpalau.com\/blog\/2021\/08\/05\/conceptos-basicos-sobre-normativa-atex-clasificacion-y-tipologia-de-equipos-a-prueba-de-explosion\/#Particularidades_de_los_ventiladores_ATEX\" >Particularidades de los ventiladores ATEX<\/a><\/li><\/ul><\/nav><\/div>\n<span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">Reading Time: <\/span> <span class=\"rt-time\"> 4<\/span> <span class=\"rt-label rt-postfix\">minutes<\/span><\/span><p><span style=\"font-weight: 400\">Existen gran cantidad de aplicaciones que se encuentran en zonas potencialmente explosivas o bien se trata de instalaciones en las que el aire o polvo que pasa a trav\u00e9s del ventilador, as\u00ed como el ambiente en d\u00f3nde est\u00e1 instalado, podr\u00eda ser clasificado como ATmosfera EXplosiva (ATEX). Una atmosfera explosiva es la mezcla con el aire de sustancias inflamables en forma de gases, vapores, nieblas o polvos, en la que, tras una ignici\u00f3n, la combusti\u00f3n se propaga a la totalidad de la mezcla no quemada.<\/span><\/p>\n<p><span style=\"font-weight: 400\">Para que se produzca una explosi\u00f3n, deben presentare simult\u00e1neamente los siguientes elementos:<\/span><!--more--><\/p>\n<p><span style=\"font-weight: 400\">Para evitar la explosi\u00f3n, bastar\u00eda con eliminar uno de estos elementos. En consecuencia, la estrategia que buscamos es la de eliminar, en la medida de lo posible, la fuente energ\u00e9tica capaz de iniciar la reacci\u00f3n, ya que no podemos hacer nada para eliminar la sustancia combustible ni el oxidante, ya que son los elementos que debemos trasegar con el ventilador.<\/span><\/p>\n<p><span style=\"font-weight: 400\">Es por ello que a nivel europeo existen varias directivas y normativas que precisamente regulan este tipo de actividades, incluyendo normativas que hacen referencia concretamente a los ventiladores, con el objetivo principal de eliminar o reducir dicha fuente de ignici\u00f3n.\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400\">Algunas de estas directivas y normativas, entre otras, son:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Directiva 2014\/34\/UE<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">UNE EN 14986:2017<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">UNE EN 80079-36<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">UNE EN 80079-37<\/span><\/li>\n<\/ul>\n<h2><span class=\"ez-toc-section\" id=\"Clasificacion_de_las_zonas_dentro_y_en_el_exterior_del_ventilador\"><\/span>Clasificaci\u00f3n de las zonas dentro y en el exterior del ventilador<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><span style=\"font-weight: 400\">En primer lugar, diferenciaremos entre el ambiente exterior y la parte interna del ventilador. Por ejemplo, es muy probable que el ventilador se encuentre instalado en el exterior (sin riesgo aparente) mientras que al aire a trasegar sea potencialmente explosivo. Es por ello que la normativa especifica las siguientes zonas y categor\u00edas (entre par\u00e9ntesis, se indica la correspondencia con la categor\u00eda indicada en la directiva ATEX):<\/span><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-3817\" src=\"http:\/\/www.solerpalau.com\/es-es\/blog\/wp-content\/uploads\/2021\/08\/SP-ATEX-1-1.png\" alt=\"normativa ATEX\" width=\"391\" height=\"305\" \/><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-3818\" src=\"http:\/\/www.solerpalau.com\/es-es\/blog\/wp-content\/uploads\/2021\/08\/SP-ATEX-2-1.png\" alt=\"normativa ATEX\" width=\"390\" height=\"380\" \/><\/p>\n<p><span style=\"font-weight: 400\">Las zonas 0, 1 y 2 indican la presencia de gases, vapores o nieblas inflamables mezclados con aire. Las zonas 20, 21 y 22 indican la presencia de polvo combustible mezclado con aire.<\/span><\/p>\n<p><span style=\"font-weight: 400\">Adem\u00e1s de la zona, se debe conocer el tipo de gas (G) o polvo (D) a ventilar. Para el caso del gas, bastar\u00e1 con conocer de qu\u00e9 gas se trata, mientras que para el polvo, se requiere saber si se trata de polvo conductivo o no conductivo.<\/span><\/p>\n<p><span style=\"font-weight: 400\">Los ventiladores para las zonas 1 (2G) y 2 (3G) est\u00e1n indicados para gases del grupo IIB o bien para\u00a0<\/span><a href=\"https:\/\/www.solerpalau.com\/blog\/es-es\/directivas-atex-maxima-prevencion-en-atmosferas-explosivas\/\"><span style=\"font-weight: 400\">atm\u00f3sferas explosivas<\/span><\/a><span style=\"font-weight: 400\">\u00a0con presencia de hidr\u00f3geno (IIB + H2) y con un tipo de temperatura T3. Los ventiladores para las zonas 21 (2D) y 22 (3D) alcanzar una temperatura m\u00e1xima superficial de 195\u00b0C. Estas temperaturas m\u00e1ximas son ejemplos y pueden ser diferentes dependiendo de la aplicaci\u00f3n estudiada.<\/span><\/p>\n<div class=\"hs-web-interactive-inline\" data-hubspot-wrapper-cta-id=\"172155039337\">\n<p>  a.hs-inline-web-interactive-172155039337link {<br \/>\n    text-decoration:none;<br \/>\n  }<\/p>\n<p>  a.hs-inline-web-interactive-172155039337hover {<br \/>\n    text-decoration:none;<br \/>\n  }<\/p>\n\n<div style=\"font-size: 18px;text-align: center\"><span style=\"color: #ce1a1a;font-family: Arial, Helvetica, sans-serif\"><strong>Asesor\u00eda gratuita de normativas | <\/strong>Nuestro equipo revisa tu proyecto para que cumpla con las regulaciones<strong> [SOLICITAR]<\/strong><\/span><\/div>\n<\/div>\n<h2><span class=\"ez-toc-section\" id=\"Particularidades_de_los_ventiladores_ATEX\"><\/span>Particularidades de los ventiladores ATEX<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><span style=\"font-weight: 400\">Una vez clasificado el ventilador en cuesti\u00f3n, el fabricante deber\u00e1 ser capaz de ofrecer una soluci\u00f3n acorde al estudio de su cliente, cumpliendo con la regulaci\u00f3n actual.<\/span><\/p>\n<p><span style=\"font-weight: 400\">Una medida frecuentemente adoptada por los fabricantes es la de utilizar el cobre como material compatible (seg\u00fan UNE EN 14986:2017) con el acero al carbono entre partes est\u00e1ticas (embocadura) y din\u00e1micas (rodete o h\u00e9lice) del ventilador. La combinaci\u00f3n de estos materiales no generar\u00eda chispa (fuente de ignici\u00f3n), evitando as\u00ed una posible explosi\u00f3n.<\/span><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-3819\" src=\"http:\/\/www.solerpalau.com\/es-es\/blog\/wp-content\/uploads\/2021\/08\/SP-ATEX-3-1.png\" alt=\"Normativa ATEX\" width=\"396\" height=\"292\" \/><\/p>\n<p><span style=\"font-weight: 400\">Entre algunas particularidades, el fabricante puede ofrecer diferentes alternativas por ejemplo cuando la atm\u00f3sfera potencialmente explosiva se encuentra presente incluso en el exterior del ventilador, adoptando precauciones adicionales, como podr\u00edan ser juntas de estanqueidad a nivel de eje. En este caso, adem\u00e1s el motor deber\u00e1 ser certificado para poder trabajar en esta concreta zona ATEX.<\/span><\/p>\n<p><span style=\"font-weight: 400\">Para el fabricante, tambi\u00e9n ser\u00e1 \u00fatil saber si el ventilador est\u00e1 controlado por un variador de frecuencia, adem\u00e1s del tipo de servicio el\u00e9ctrico, es decir, si funcionar\u00e1 siempre en continuo o bien si existir\u00e1n variaciones peri\u00f3dicas de la velocidad, y finalmente, el n\u00famero de puestas en marcha por hora del motor.<\/span><\/p>\n<p><span style=\"font-weight: 400\">Como \u00faltimos datos a tener en cuenta por el fabricante, se debe proporcionar la temperatura m\u00e1xima del fluido aspirado por el ventilador, la temperatura m\u00e1xima del ambiente donde se instalar\u00e1 el ventilador y la temperatura m\u00e1xima superficial admisible en las zonas clasificadas como potencialmente explosivas, tanto interior como exterior.<\/span><span style=\"font-weight: 400\"><br \/><\/span><span style=\"font-weight: 400\">La m\u00e1xima temperatura superficial es la parte m\u00e1s caliente del equipo que puede entrar en contacto con la atm\u00f3sfera explosiva, o bien la temperatura m\u00e1xima del fluido transportado que puede actuar como una fuente de ignici\u00f3n, seg\u00fan la normativa UNE EN 14986:2017.<\/span><\/p>\n<p><span style=\"font-weight: 400\">Con toda esta informaci\u00f3n, el fabricante del ventilador ser\u00e1 capaz de seleccionar el ventilador m\u00e1s adecuado para la aplicaci\u00f3n ATEX en cuesti\u00f3n, sin poner en riesgo la seguridad y la salud de los trabajadores que se encuentran en la zona potencialmente explosiva.<\/span><\/p>\n\n\n<div class=\"hs-cta-embed hs-cta-simple-placeholder hs-cta-embed-171915633068\" style=\"max-width:100%;max-height:100%;width:650px;height:304px\" data-hubspot-wrapper-cta-id=\"171915633068\">\n  <a href=\"https:\/\/cta-service-cms2.hubspot.com\/web-interactives\/public\/v1\/track\/redirect?encryptedPayload=AVxigLL2YePnW374BTC%2FY%2Fa46WrR3161J72QlGc3YHsH1rhPH8dvRKXIoXJV8hAoHfDFmF6qyTyT8qOD%2BIg%2Bxy5iwOOx6kgDrfFbzofyDhRhyk4%2BegJJC8kQ5iH0J77D%2Bru8SGhjB0Uq8TsBRB4Xnsm7RQir7Og1TyBjhLzgK8gwEjszFf6EvWtBPd9ELxZDCJatjVzjvZexFlqCKeQO8%2B7P1w%3D%3D&amp;webInteractiveContentId=171915633068&amp;portalId=2009592\" target=\"_blank\" rel=\"noopener\">\n    <img decoding=\"async\" alt=\"Asesor&iacute;a gratuita de normativas&nbsp;\" loading=\"lazy\" src=\"https:\/\/no-cache.hubspot.com\/cta\/default\/2009592\/interactive-171915633068.png\" style=\"height: 100%;width: 100%;object-fit: fill\" \/>\n  <\/a>\n<\/div>\n\n","protected":false},"excerpt":{"rendered":"<p><span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">Reading Time: <\/span> <span class=\"rt-time\"> 4<\/span> <span class=\"rt-label rt-postfix\">minutes<\/span><\/span>Existen gran cantidad de aplicaciones que se encuentran en zonas potencialmente explosivas o bien se trata de instalaciones en las que el aire o polvo que pasa a trav\u00e9s del ventilador, as\u00ed como el ambiente en d\u00f3nde est\u00e1 instalado, podr\u00eda ser clasificado como ATmosfera EXplosiva (ATEX). Una atmosfera explosiva es la mezcla con el aire<\/p>\n","protected":false},"author":10,"featured_media":3820,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[5],"tags":[],"class_list":["post-3815","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-normativas-de-ventilacion-de-espacios"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.1 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Conceptos b\u00e1sicos sobre normativa ATEX: Clasificaci\u00f3n y tipolog\u00eda de equipos a prueba de explosi\u00f3n | S&amp;P<\/title>\n<meta name=\"robots\" content=\"noindex, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Conceptos b\u00e1sicos sobre normativa ATEX: Clasificaci\u00f3n y tipolog\u00eda de equipos a prueba de explosi\u00f3n | S&amp;P\" \/>\n<meta property=\"og:description\" content=\"Reading Time:  4 minutesExisten gran cantidad de aplicaciones que se encuentran en zonas potencialmente explosivas o bien se trata de instalaciones en las que el aire o polvo que pasa a trav\u00e9s del ventilador, as\u00ed como el ambiente en d\u00f3nde est\u00e1 instalado, podr\u00eda ser clasificado como ATmosfera EXplosiva (ATEX). Una atmosfera explosiva es la mezcla con el aire\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.solerpalau.com\/blog\/2021\/08\/05\/conceptos-basicos-sobre-normativa-atex-clasificacion-y-tipologia-de-equipos-a-prueba-de-explosion\/\" \/>\n<meta property=\"og:site_name\" content=\"S&amp;P \/blog no visible\" \/>\n<meta property=\"article:published_time\" content=\"2021-08-05T08:08:00+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.solerpalau.com\/blog\/wp-content\/uploads\/2021\/08\/Atmosfera-explosiva-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"627\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"S&amp;P\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t<meta name=\"twitter:data1\" content=\"S&amp;P\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tiempo de lectura\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minutos\" \/>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Conceptos b\u00e1sicos sobre normativa ATEX: Clasificaci\u00f3n y tipolog\u00eda de equipos a prueba de explosi\u00f3n | S&P","robots":{"index":"noindex","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"og_locale":"es_ES","og_type":"article","og_title":"Conceptos b\u00e1sicos sobre normativa ATEX: Clasificaci\u00f3n y tipolog\u00eda de equipos a prueba de explosi\u00f3n | S&P","og_description":"Reading Time:  4 minutesExisten gran cantidad de aplicaciones que se encuentran en zonas potencialmente explosivas o bien se trata de instalaciones en las que el aire o polvo que pasa a trav\u00e9s del ventilador, as\u00ed como el ambiente en d\u00f3nde est\u00e1 instalado, podr\u00eda ser clasificado como ATmosfera EXplosiva (ATEX). Una atmosfera explosiva es la mezcla con el aire","og_url":"https:\/\/www.solerpalau.com\/blog\/2021\/08\/05\/conceptos-basicos-sobre-normativa-atex-clasificacion-y-tipologia-de-equipos-a-prueba-de-explosion\/","og_site_name":"S&amp;P \/blog no visible","article_published_time":"2021-08-05T08:08:00+00:00","og_image":[{"width":1200,"height":627,"url":"https:\/\/www.solerpalau.com\/blog\/wp-content\/uploads\/2021\/08\/Atmosfera-explosiva-1.jpg","type":"image\/jpeg"}],"author":"S&amp;P","twitter_card":"summary_large_image","twitter_misc":{"Escrito por":"S&amp;P","Tiempo de lectura":"5 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.solerpalau.com\/blog\/2021\/08\/05\/conceptos-basicos-sobre-normativa-atex-clasificacion-y-tipologia-de-equipos-a-prueba-de-explosion\/","url":"https:\/\/www.solerpalau.com\/blog\/2021\/08\/05\/conceptos-basicos-sobre-normativa-atex-clasificacion-y-tipologia-de-equipos-a-prueba-de-explosion\/","name":"Conceptos b\u00e1sicos sobre normativa ATEX: Clasificaci\u00f3n y tipolog\u00eda de equipos a prueba de explosi\u00f3n | S&P","isPartOf":{"@id":"https:\/\/www.solerpalau.com\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.solerpalau.com\/blog\/2021\/08\/05\/conceptos-basicos-sobre-normativa-atex-clasificacion-y-tipologia-de-equipos-a-prueba-de-explosion\/#primaryimage"},"image":{"@id":"https:\/\/www.solerpalau.com\/blog\/2021\/08\/05\/conceptos-basicos-sobre-normativa-atex-clasificacion-y-tipologia-de-equipos-a-prueba-de-explosion\/#primaryimage"},"thumbnailUrl":"https:\/\/www.solerpalau.com\/blog\/wp-content\/uploads\/2021\/08\/Atmosfera-explosiva-1.jpg","datePublished":"2021-08-05T08:08:00+00:00","author":{"@id":"https:\/\/www.solerpalau.com\/blog\/#\/schema\/person\/a649fcc0fccdca5446ea2bc371ad5cb9"},"breadcrumb":{"@id":"https:\/\/www.solerpalau.com\/blog\/2021\/08\/05\/conceptos-basicos-sobre-normativa-atex-clasificacion-y-tipologia-de-equipos-a-prueba-de-explosion\/#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.solerpalau.com\/blog\/2021\/08\/05\/conceptos-basicos-sobre-normativa-atex-clasificacion-y-tipologia-de-equipos-a-prueba-de-explosion\/"]}]},{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/www.solerpalau.com\/blog\/2021\/08\/05\/conceptos-basicos-sobre-normativa-atex-clasificacion-y-tipologia-de-equipos-a-prueba-de-explosion\/#primaryimage","url":"https:\/\/www.solerpalau.com\/blog\/wp-content\/uploads\/2021\/08\/Atmosfera-explosiva-1.jpg","contentUrl":"https:\/\/www.solerpalau.com\/blog\/wp-content\/uploads\/2021\/08\/Atmosfera-explosiva-1.jpg","width":1200,"height":627,"caption":"Atmosfera explosiva"},{"@type":"BreadcrumbList","@id":"https:\/\/www.solerpalau.com\/blog\/2021\/08\/05\/conceptos-basicos-sobre-normativa-atex-clasificacion-y-tipologia-de-equipos-a-prueba-de-explosion\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Portada","item":"https:\/\/www.solerpalau.com\/blog\/"},{"@type":"ListItem","position":2,"name":"Conceptos b\u00e1sicos sobre normativa ATEX: Clasificaci\u00f3n y tipolog\u00eda de equipos a prueba de explosi\u00f3n"}]},{"@type":"WebSite","@id":"https:\/\/www.solerpalau.com\/blog\/#website","url":"https:\/\/www.solerpalau.com\/blog\/","name":"S&amp;P \/blog no visible","description":"El Blog de ventilaci\u00f3n eficiente para una mejor calidad del aire","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.solerpalau.com\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es"},{"@type":"Person","@id":"https:\/\/www.solerpalau.com\/blog\/#\/schema\/person\/a649fcc0fccdca5446ea2bc371ad5cb9","name":"S&amp;P","image":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/www.solerpalau.com\/blog\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/994644236667321375ba4d21a34a002e2bcfd7b33a114caa4c9dc488ece6c970?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/994644236667321375ba4d21a34a002e2bcfd7b33a114caa4c9dc488ece6c970?s=96&d=mm&r=g","caption":"S&amp;P"},"url":"https:\/\/www.solerpalau.com\/blog\/author\/binaria\/"}]}},"reading_time":"<span class=\"span-reading-time rt-reading-time\"><span class=\"rt-label rt-prefix\"><\/span> <span class=\"rt-time\"> 4<\/span> <span class=\"rt-label rt-postfix\"> min. de lectura<\/span><\/span>","_links":{"self":[{"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/posts\/3815","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/users\/10"}],"replies":[{"embeddable":true,"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/comments?post=3815"}],"version-history":[{"count":0,"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/posts\/3815\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/media\/3820"}],"wp:attachment":[{"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/media?parent=3815"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/categories?post=3815"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/tags?post=3815"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}