{"id":420,"date":"2017-01-09T08:00:53","date_gmt":"2017-01-09T07:00:53","guid":{"rendered":"https:\/\/www.solerpalau.com\/blog\/?p=420"},"modified":"2019-04-15T10:48:44","modified_gmt":"2019-04-15T08:48:44","slug":"db-hs-3-calidad-del-aire-interior","status":"publish","type":"post","link":"https:\/\/www.solerpalau.com\/blog\/2017\/01\/09\/db-hs-3-calidad-del-aire-interior\/","title":{"rendered":"DB HS 3. Exigencias de la Calidad del aire interior"},"content":{"rendered":"<span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">Reading Time: <\/span> <span class=\"rt-time\"> 3<\/span> <span class=\"rt-label rt-postfix\">minutes<\/span><\/span><p><span style=\"font-weight: 400;\">El <strong>CTE (C\u00f3digo T\u00e9cnico de la Edificaci\u00f3n)<\/strong> supuso un cambio en el paradigma regulatorio y normativo de la edificaci\u00f3n en Espa\u00f1a, al introducir una nueva regulaci\u00f3n que busca una soluci\u00f3n integral para construir edificios que cumplan con todos los requisitos b\u00e1sicos para considerarlos seguros, habitables, confortables y sostenibles. <\/span><!--more--><\/p>\n<p><span style=\"font-weight: 400;\">Dentro de esta normativa se detalla una estructura basada en <strong>Documentos B\u00e1sicos (DB)<\/strong> que recogen los aspectos esenciales a cumplir en diferentes \u00e1mbitos del edificio. De forma concreta el DB HS contiene los requerimientos para la salubridad en los edificios y su apartado HS 3 indica las exigencias de Calidad del Aire Interior. Es importante mencionar de nuevo que se habla de exigencia b\u00e1sica, por lo tanto su cumplimiento es obligatorio en los \u00e1mbitos donde tiene aplicaci\u00f3n el CTE.<\/span><\/p>\n<p style=\"text-align: center;\"><span data-sheets-value=\"{&quot;1&quot;:2,&quot;2&quot;:&quot;[cta_hubspot id=33]&quot;}\" data-sheets-userformat=\"{&quot;2&quot;:14851,&quot;3&quot;:{&quot;1&quot;:0},&quot;4&quot;:{&quot;1&quot;:2,&quot;2&quot;:16777215},&quot;12&quot;:0,&quot;14&quot;:{&quot;1&quot;:2,&quot;2&quot;:4473924},&quot;15&quot;:&quot;Consolas, Monaco, monospace&quot;,&quot;16&quot;:8}\">[cta_hubspot id=33]<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Los edificios deben contar con un sistema que garantice que el recinto est\u00e9 adecuadamente ventilado y que permita que durante un uso normal del edificio se puedan eliminar los contaminantes que se producen habitualmente mediante la aportaci\u00f3n de unos caudales de ventilaci\u00f3n adecuados.<\/span><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-424\" src=\"https:\/\/www.solerpalau.com\/blog\/wp-content\/uploads\/2017\/01\/iStock-496775484.jpg\" alt=\"\" width=\"725\" height=\"482\" srcset=\"https:\/\/www.solerpalau.com\/blog\/wp-content\/uploads\/2017\/01\/iStock-496775484.jpg 725w, https:\/\/www.solerpalau.com\/blog\/wp-content\/uploads\/2017\/01\/iStock-496775484-600x399.jpg 600w\" sizes=\"auto, (max-width: 725px) 100vw, 725px\" \/><\/p>\n<p><span style=\"font-weight: 400;\">La normativa actual obliga a llevar este aire viciado, mediante conductos, a la zona m\u00e1s alta del edificio, minimizando de esta forma el riesgo de contaminaci\u00f3n cruzada. Esta obligatoriedad tiene adem\u00e1s evidentes ventajas desde un punto de vista est\u00e9tico y de uniformidad del edificio, al no existir conductos visibles en la fachada.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Centr\u00e1ndonos en el HS 3 el primer aspecto importante es d\u00f3nde se aplica:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\"><strong>Edificios de viviendas:<\/strong> interior de las viviendas, almacenes para residuos, aparcamientos, trasteros y garajes<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\"><strong>Edificios de otro uso:<\/strong> aparcamientos y garajes. Es importante mencionar que las zonas de circulaci\u00f3n o paso habitual de veh\u00edculos tambi\u00e9n tienen esta consideraci\u00f3n.<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\"><strong>Locales con otro tipo de uso:<\/strong> no aplica de forma directa sino que debe de utilizarse un procedimiento an\u00e1logo al utilizado en el HS 3, garantizando que las exigencias b\u00e1sicas son cumplidas<\/span><\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p><span style=\"font-weight: 400;\">La exigencia b\u00e1sica ha de verificarse mediante la verificaci\u00f3n y cumplimiento de 6 aspectos diferenciados:<\/span><\/p>\n<ol>\n<li style=\"font-weight: 400;\"><strong>Caudales: <\/strong>debe proporcionarse un caudal de aire de renovaci\u00f3n en funci\u00f3n del tipo de estancia, uso y ocupaci\u00f3n<\/li>\n<li style=\"font-weight: 400;\"><strong>Dise\u00f1o del sistema: <\/strong>pueden usarse sistemas naturales, h\u00edbridos o mec\u00e1nicos<\/li>\n<li style=\"font-weight: 400;\"><strong>Dimensionado: <\/strong>los elementos del sistema se deben dimensionar siguiendo unos criterios espec\u00edficos, que garanticen un funcionamiento adecuado<\/li>\n<li style=\"font-weight: 400;\"><strong>Productos de construcci\u00f3n: <\/strong>especificando el cumplimiento de unos requisitos para los materiales constructivos de los equipos de ventilaci\u00f3n<\/li>\n<li style=\"font-weight: 400;\"><strong>Construcci\u00f3n:<\/strong> relativo a la construcci\u00f3n del sistema de ventilaci\u00f3n<\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\"><strong>Mantenimiento y conservaci\u00f3n:<\/strong> se detallan los requerimientos m\u00ednimos exigibles para garantizar un adecuado estado de conservaci\u00f3n y mantenimiento de los elementos del sistema de ventilaci\u00f3n<\/span><\/li>\n<\/ol>\n<p><span style=\"font-weight: 400;\">Estas exigencias se detallan para cada tipo de lugar de aplicaci\u00f3n (viviendas y edificios de otro uso, en todas las estancias mencionadas anteriormente) debi\u00e9ndose justificar debidamente cada punto. <\/span><\/p>\n<p><span style=\"font-weight: 400;\">Es importante mencionar y hacer hincapi\u00e9 en que los requisitos legales obligan a unos m\u00ednimos que deben cumplirse, pero existen soluciones que adem\u00e1s de garantizar el cumplimiento de las exigencias b\u00e1sicas permiten mejorar y optimizar los par\u00e1metros \u00a0y ahorro energ\u00e9tico. <\/span><\/p>\n<p><span style=\"font-weight: 400;\">Este aspecto cr\u00edtico est\u00e1 determinado espec\u00edficamente por el sistema utilizado (punto 2), ya que un sistema de ventilaci\u00f3n que no cuente con un control mec\u00e1nico de la cantidad de aire introducido, buscando el \u00f3ptimo que garantice la salubridad del aire pero sin que suponga una carga energ\u00e9tica elevada, dar\u00e1 lugar a un aumento de la demanda energ\u00e9tica por excesiva renovaci\u00f3n de aire. La ventilaci\u00f3n supone la introducci\u00f3n de aire de ventilaci\u00f3n del exterior, que no est\u00e1 en las condiciones de temperatura y humedad requerida, debiendo los sistemas de climatizaci\u00f3n aportar la energ\u00eda necesaria para calentarlo (pensando en una operativa en modo \u201ccalefacci\u00f3n\u201d). La tecnolog\u00eda utilizada, teniendo en cuenta que la ventilaci\u00f3n natural no est\u00e1 permitida por la normativa, es la que va a hacer que se puedan cumplir de forma \u00f3ptima los dos criterios de ventilaci\u00f3n y ahorro energ\u00e9tico.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Para ello podemos optar por sistemas de simple o doble flujo, permitiendo los sistemas de doble flujo instalar un sistema de recuperaci\u00f3n de energ\u00eda, que sirve para precalentar el aire introducido al edificio. Si adem\u00e1s de recuperar energ\u00eda logramos que el caudal impulsado sea el adecuado para lograr la calidad de aire interior requerida pero sin ventilar en exceso (sistema de Demanda Controlada de Ventilaci\u00f3n, DCV) logramos la mayor eficiencia posible en el sistema. Por lo tanto el analizar como un problema de conjunto la soluci\u00f3n a instalar es clave para garantizar una soluci\u00f3n que no sea de m\u00ednimos, es decir, orientada al simple cumplimiento de la normativa, sino una soluci\u00f3n sin dejar de pensar en la habitabilidad y costes de explotaci\u00f3n del edificio.<\/span><\/p>\n<p><span data-sheets-value=\"{&quot;1&quot;:2,&quot;2&quot;:&quot;[cta_hubspot id=122]&quot;}\" data-sheets-userformat=\"{&quot;2&quot;:14851,&quot;3&quot;:{&quot;1&quot;:0},&quot;4&quot;:{&quot;1&quot;:2,&quot;2&quot;:16777215},&quot;12&quot;:0,&quot;14&quot;:{&quot;1&quot;:2,&quot;2&quot;:4473924},&quot;15&quot;:&quot;Consolas, Monaco, monospace&quot;,&quot;16&quot;:8}\">[cta_hubspot id=122]<\/span><\/p>\n","protected":false},"excerpt":{"rendered":"<p><span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">Reading Time: <\/span> <span class=\"rt-time\"> 3<\/span> <span class=\"rt-label rt-postfix\">minutes<\/span><\/span>El CTE (C\u00f3digo T\u00e9cnico de la Edificaci\u00f3n) supuso un cambio en el paradigma regulatorio y normativo de la edificaci\u00f3n en Espa\u00f1a, al introducir una nueva regulaci\u00f3n que busca una soluci\u00f3n integral para construir edificios que cumplan con todos los requisitos b\u00e1sicos para considerarlos seguros, habitables, confortables y sostenibles.<\/p>\n","protected":false},"author":10,"featured_media":425,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[8],"tags":[],"class_list":["post-420","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-asesoria-tecnica"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.1 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>DB HS 3. Exigencias de la Calidad del aire interior<\/title>\n<meta name=\"description\" content=\"El DB HS contiene los requerimientos para la salubridad en los edificios y su apartado HS 3 indica las exigencias de Calidad del Aire Interior.\" \/>\n<meta name=\"robots\" content=\"noindex, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"DB HS 3. Exigencias de la Calidad del aire interior\" \/>\n<meta property=\"og:description\" content=\"El DB HS contiene los requerimientos para la salubridad en los edificios y su apartado HS 3 indica las exigencias de Calidad del Aire Interior.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.solerpalau.com\/blog\/cte-db-hs3-calidad-aire-interior\/\" \/>\n<meta property=\"og:site_name\" content=\"S&amp;P \/blog no visible\" \/>\n<meta property=\"article:published_time\" content=\"2017-01-09T07:00:53+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2019-04-15T08:48:44+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.solerpalau.com\/blog\/wp-content\/uploads\/2017\/01\/iStock-498723104.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"724\" \/>\n\t<meta property=\"og:image:height\" content=\"483\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"S&amp;P\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t<meta name=\"twitter:data1\" content=\"S&amp;P\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tiempo de lectura\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutos\" \/>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"DB HS 3. Exigencias de la Calidad del aire interior","description":"El DB HS contiene los requerimientos para la salubridad en los edificios y su apartado HS 3 indica las exigencias de Calidad del Aire Interior.","robots":{"index":"noindex","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"og_locale":"es_ES","og_type":"article","og_title":"DB HS 3. Exigencias de la Calidad del aire interior","og_description":"El DB HS contiene los requerimientos para la salubridad en los edificios y su apartado HS 3 indica las exigencias de Calidad del Aire Interior.","og_url":"https:\/\/www.solerpalau.com\/blog\/cte-db-hs3-calidad-aire-interior\/","og_site_name":"S&amp;P \/blog no visible","article_published_time":"2017-01-09T07:00:53+00:00","article_modified_time":"2019-04-15T08:48:44+00:00","og_image":[{"width":724,"height":483,"url":"https:\/\/www.solerpalau.com\/blog\/wp-content\/uploads\/2017\/01\/iStock-498723104.jpg","type":"image\/jpeg"}],"author":"S&amp;P","twitter_card":"summary_large_image","twitter_misc":{"Escrito por":"S&amp;P","Tiempo de lectura":"4 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.solerpalau.com\/blog\/2017\/01\/09\/db-hs-3-calidad-del-aire-interior\/","url":"https:\/\/www.solerpalau.com\/blog\/cte-db-hs3-calidad-aire-interior\/","name":"DB HS 3. Exigencias de la Calidad del aire interior","isPartOf":{"@id":"https:\/\/www.solerpalau.com\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.solerpalau.com\/blog\/cte-db-hs3-calidad-aire-interior\/#primaryimage"},"image":{"@id":"https:\/\/www.solerpalau.com\/blog\/cte-db-hs3-calidad-aire-interior\/#primaryimage"},"thumbnailUrl":"https:\/\/www.solerpalau.com\/blog\/wp-content\/uploads\/2017\/01\/iStock-498723104.jpg","datePublished":"2017-01-09T07:00:53+00:00","dateModified":"2019-04-15T08:48:44+00:00","author":{"@id":"https:\/\/www.solerpalau.com\/blog\/#\/schema\/person\/a649fcc0fccdca5446ea2bc371ad5cb9"},"description":"El DB HS contiene los requerimientos para la salubridad en los edificios y su apartado HS 3 indica las exigencias de Calidad del Aire Interior.","breadcrumb":{"@id":"https:\/\/www.solerpalau.com\/blog\/cte-db-hs3-calidad-aire-interior\/#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.solerpalau.com\/blog\/cte-db-hs3-calidad-aire-interior\/"]}]},{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/www.solerpalau.com\/blog\/cte-db-hs3-calidad-aire-interior\/#primaryimage","url":"https:\/\/www.solerpalau.com\/blog\/wp-content\/uploads\/2017\/01\/iStock-498723104.jpg","contentUrl":"https:\/\/www.solerpalau.com\/blog\/wp-content\/uploads\/2017\/01\/iStock-498723104.jpg","width":724,"height":483,"caption":"db hs 3 calidad aire interior"},{"@type":"BreadcrumbList","@id":"https:\/\/www.solerpalau.com\/blog\/cte-db-hs3-calidad-aire-interior\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Portada","item":"https:\/\/www.solerpalau.com\/blog\/"},{"@type":"ListItem","position":2,"name":"DB HS 3. Exigencias de la Calidad del aire interior"}]},{"@type":"WebSite","@id":"https:\/\/www.solerpalau.com\/blog\/#website","url":"https:\/\/www.solerpalau.com\/blog\/","name":"S&amp;P \/blog no visible","description":"El Blog de ventilaci\u00f3n eficiente para una mejor calidad del aire","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.solerpalau.com\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es"},{"@type":"Person","@id":"https:\/\/www.solerpalau.com\/blog\/#\/schema\/person\/a649fcc0fccdca5446ea2bc371ad5cb9","name":"S&amp;P","image":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/www.solerpalau.com\/blog\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/994644236667321375ba4d21a34a002e2bcfd7b33a114caa4c9dc488ece6c970?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/994644236667321375ba4d21a34a002e2bcfd7b33a114caa4c9dc488ece6c970?s=96&d=mm&r=g","caption":"S&amp;P"},"url":"https:\/\/www.solerpalau.com\/blog\/author\/binaria\/"}]}},"reading_time":"<span class=\"span-reading-time rt-reading-time\"><span class=\"rt-label rt-prefix\"><\/span> <span class=\"rt-time\"> 3<\/span> <span class=\"rt-label rt-postfix\"> min. de lectura<\/span><\/span>","_links":{"self":[{"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/posts\/420","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/users\/10"}],"replies":[{"embeddable":true,"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/comments?post=420"}],"version-history":[{"count":3,"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/posts\/420\/revisions"}],"predecessor-version":[{"id":426,"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/posts\/420\/revisions\/426"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/media\/425"}],"wp:attachment":[{"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/media?parent=420"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/categories?post=420"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/tags?post=420"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}