{"id":4279,"date":"2022-01-24T08:30:56","date_gmt":"2022-01-24T07:30:56","guid":{"rendered":"http:\/\/www.solerpalau.com\/es-es\/blog\/?p=4279"},"modified":"2022-01-24T08:30:56","modified_gmt":"2022-01-24T07:30:56","slug":"norma-une-23585","status":"publish","type":"post","link":"https:\/\/www.solerpalau.com\/blog\/2022\/01\/24\/norma-une-23585\/","title":{"rendered":"Norma UNE 23585 de control de humos"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_76 counter-hierarchy ez-toc-counter ez-toc-custom ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Table of Contents<\/p>\n<span class=\"ez-toc-title-toggle\"><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.solerpalau.com\/blog\/2022\/01\/24\/norma-une-23585\/#Novedades_en_la_Norma_UNE_23585_de_control_de_humos\" >Novedades en la Norma UNE 23585 de control de humos<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.solerpalau.com\/blog\/2022\/01\/24\/norma-une-23585\/#Cambios_de_los_requisitos_establecidos_en_la_Norma_UNE_23585\" >Cambios de los requisitos establecidos en la Norma UNE 23585<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.solerpalau.com\/blog\/2022\/01\/24\/norma-une-23585\/#El_impacto_de_las_influencias_externas\" >El impacto de las influencias externas<\/a><\/li><\/ul><\/nav><\/div>\n<span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">Reading Time: <\/span> <span class=\"rt-time\"> 4<\/span> <span class=\"rt-label rt-postfix\">minutes<\/span><\/span><p><span style=\"font-weight: 400\">Cuando, desde la perspectiva de la calidad del aire, se habla de pol\u00edticas de prevenci\u00f3n de riesgos laborales y de mejora del bienestar en los centros de trabajo, suele ponerse el foco en aquellas medidas que se refieren a controlar el ambiente en una situaci\u00f3n de normalidad. Sin embargo, es igual de importante que una empresa cuente con sistemas adecuados para poder reaccionar ante adversidades que son m\u00e1s frecuentes de lo que parece, como los incendios. En este sentido, la <\/span><b>Norma UNE 23585 de control de humos<\/b><span style=\"font-weight: 400\"> es esencial, porque se fija justo en el factor que m\u00e1s v\u00edctimas provoca: la inhalaci\u00f3n de humo producto de la combusti\u00f3n, que es altamente t\u00f3xico.<\/span><!--more--><\/p>\n<h2><span class=\"ez-toc-section\" id=\"Novedades_en_la_Norma_UNE_23585_de_control_de_humos\"><\/span>Novedades en la Norma UNE 23585 de control de humos<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><span style=\"font-weight: 400\">La aparici\u00f3n de la Norma UNE 23585 de control de humos supuso un significativo avance en materia de <\/span><b>instalaci\u00f3n de sistemas de control de temperatura y evacuaci\u00f3n de humos (SCTEH)<\/b><span style=\"font-weight: 400\">. Pero conviene tener presente que se trata de un \u00e1mbito que est\u00e1 en continuo proceso de evoluci\u00f3n, de ah\u00ed la importancia de actualizar este tipo de legislaci\u00f3n para ir incorporando los nuevos avances y descubrimientos que se producen, siempre teniendo claro que el objetivo de estos sistemas es la protecci\u00f3n y seguridad de las personas.<\/span><\/p>\n<p><span style=\"font-weight: 400\">Respecto a la normativa vigente con anterioridad, la norma UNE 23585 del a\u00f1o 2004, la <\/span><b>revisi\u00f3n de 2017 se ha elaborado atendiendo a cuatro ejes de mejora<\/b><span style=\"font-weight: 400\">:<\/span><\/p>\n<ol>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Adaptarse a los avances tecnol\u00f3gicos y cient\u00edficos constatados en el seno del Comit\u00e9 Europeo de Normalizaci\u00f3n dedicado a este \u00e1mbito, el CEN TC191\/SC1.<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Aportar soluciones que permitan que los SCTEH respondan a las nuevas necesidades y <\/span><a href=\"https:\/\/www.solerpalau.com\/blog\/es-es\/economia-circular-construccion\/\"><span style=\"font-weight: 400\">tendencias en construcci\u00f3n y edificaci\u00f3n<\/span><\/a><span style=\"font-weight: 400\">, sin que se reduzcan los niveles de seguridad y las prestaciones en lo que se refiere al control de humos.<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Aclarar todos los aspectos que generan confusi\u00f3n a la hora de dimensionar los sistemas de control de humos.<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Unificar los criterios que se emplean como par\u00e1metros para calcular las dimensiones de los SCTEH.<\/span><\/li>\n<\/ol>\n<h2><span class=\"ez-toc-section\" id=\"Cambios_de_los_requisitos_establecidos_en_la_Norma_UNE_23585\"><\/span>Cambios de los requisitos establecidos en la Norma UNE 23585<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><span style=\"font-weight: 400\">A la hora de analizar la nueva propuesta de la Norma UNE 23585, lo m\u00e1s importante es fijarse en las aportaciones que afectan a las tres categor\u00edas principales de esta normativa:<\/span><\/p>\n<h3>Los requisitos de dise\u00f1o<\/h3>\n<p><span style=\"font-weight: 400\">Nos referimos en este apartado a las modificaciones planteadas en la Norma UNE 23585:2017 con el objetivo de eliminar la divergencia de criterios que hasta ahora se utilizaban para dimensionar los sistemas de control de humos. Es decir, la idea es que se pueda contar con un m\u00e9todo de c\u00e1lculo m\u00e1s objetivo y que evite la disparidad de planteamientos y dise\u00f1os entre los t\u00e9cnicos consultados. Ahora se establecen cuatro tablas que recogen los distintos <\/span><a href=\"https:\/\/www.solerpalau.com\/blog\/es-es\/cte-incendios-edificios\/\"><span style=\"font-weight: 400\">modelos de incendios<\/span><\/a><span style=\"font-weight: 400\">,<\/span><span style=\"font-weight: 400\"> teniendo en cuenta aspectos como la existencia o no de rociadores y la altura cr\u00edtica de almacenaje o apilado de productos.<\/span><\/p>\n<p><span style=\"font-weight: 400\">En cada uno de los modelos de incendios establecidos, adem\u00e1s, se especifican los par\u00e1metros que se tienen que valorar para el dise\u00f1o del SCTEH. Son tres:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">El \u00e1rea del incendio.<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">El per\u00edmetro del incendio.<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">El flujo de calor que se libera.<\/span><\/li>\n<\/ul>\n<div class=\"hs-web-interactive-inline\" data-hubspot-wrapper-cta-id=\"172155039337\">\n\n<p>  a.hs-inline-web-interactive-172155039337link {<br \/>\n    text-decoration:none;<br \/>\n  }<\/p>\n<p>  a.hs-inline-web-interactive-172155039337hover {<br \/>\n    text-decoration:none;<br \/>\n  }<\/p>\n\n<div style=\"font-size: 18px;text-align: center\"><span style=\"color: #ce1a1a;font-family: Arial, Helvetica, sans-serif\"><strong>Asesor\u00eda gratuita de normativas | <\/strong>Nuestro equipo revisa tu proyecto para que cumpla con las regulaciones<strong> [SOLICITAR]<\/strong><\/span><\/div>\n<\/div>\n<h3>Los requisitos operacionales<\/h3>\n<p><span style=\"font-weight: 400\">Esta es una de las \u00e1reas en las que mayores diferencias se aprecian entre la anterior Norma UNE 23585 y su actualizaci\u00f3n de 2017. En concreto, en lo que se refiere al uso indistinto de sistemas de evacuaci\u00f3n de humos mediante aireadores naturales o mec\u00e1nicos. Esta nueva versi\u00f3n se alinea con lo establecido en el <\/span><a href=\"https:\/\/www.solerpalau.com\/blog\/es-es\/documento-hs3-del-codigo-tecnico-la-edificacion\/\"><span style=\"font-weight: 400\">C\u00f3digo T\u00e9cnico de la Edificaci\u00f3n<\/span><\/a><span style=\"font-weight: 400\"> y en el RIPCI.<\/span><\/p>\n<p><span style=\"font-weight: 400\">Uno de los puntos en los que incide la nueva normativa es en la <\/span><b>necesidad de que la entrada de aire de reemplazamiento no genere turbulencias que afecten al dep\u00f3sito de humos<\/b><span style=\"font-weight: 400\">. Para regularlo, incluye limitaciones concretas respecto a la velocidad m\u00e1xima del aire, dependiendo de la distancia entre la entrada y la base de la capa de humos.<\/span><\/p>\n<h2><span class=\"ez-toc-section\" id=\"El_impacto_de_las_influencias_externas\"><\/span>El impacto de las influencias externas<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><span style=\"font-weight: 400\">En esta reforma de la Norma UNE 23585, no se ha dejado de lado un factor tan decisivo como es la influencia de los fen\u00f3menos meteorol\u00f3gicos cuando se habla de control de humos. Especialmente, hay tres elementos condicionantes:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400\"><b>El viento<\/b><span style=\"font-weight: 400\">: dependiendo de su intensidad, puede provocar un efecto de succi\u00f3n o de sobrepresi\u00f3n que afecte a los puntos de entrada de aire y salida de humos.<\/span><\/li>\n<li style=\"font-weight: 400\"><b>La temperatura exterior<\/b><span style=\"font-weight: 400\">: se sustituye la referencia a la Norma Europea EN 1991-2-5 por la que figura en la tabla E-1 del DB-SE-AE.\u00a0<\/span><\/li>\n<li style=\"font-weight: 400\"><b>La nieve<\/b><span style=\"font-weight: 400\">: se establece como criterio de valores de carga de nieve los establecidos en la DB-SE-AE a trav\u00e9s de su tabla E-2, frente a los anteriores (Norma Europea EN 1991-2-3).<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400\">Esta \u00faltima actualizaci\u00f3n de la Norma UNE 23585 ha servido para paliar muchos de los problemas que su antecesora causaba a la hora de dise\u00f1ar e implantar los SCTEH. Sin duda, para garantizar la calidad del aire, ser\u00e1 interesante seguir con inter\u00e9s cualquier avance futuro que se produzca en un \u00e1mbito tan importante como es el del control de humos.<\/span><\/p>\n\n\n<div class=\"hs-cta-embed hs-cta-simple-placeholder hs-cta-embed-171915633068\" style=\"max-width:100%;max-height:100%;width:700px;height:289px\" data-hubspot-wrapper-cta-id=\"171915633068\">\n  <a href=\"https:\/\/cta-service-cms2.hubspot.com\/web-interactives\/public\/v1\/track\/redirect?encryptedPayload=AVxigLKc%2BQb0IDMkwSTZLzCV8olIQBj%2FHDqZBr5wU9If8t61p7y0r%2B%2FB9mnfRh0gAUU5APtUjBHIqlIjbHHltep7T%2FBTXMlcOFoAaoGqwp2vaDXGz6cPhuV2b7VQtHbKvgWk3CWi2fwGK03gUZ95eeOQY1aLEn4i12KWGVcqAY8SH%2Bp%2BnOiAY5BxeVBg4NM%2FJ6ayPBZpiYl1DQ3x6eTrRonb2A%3D%3D&amp;webInteractiveContentId=171915633068&amp;portalId=2009592\" target=\"_blank\" rel=\"noopener\">\n    <img decoding=\"async\" alt=\"Asesor&iacute;a gratuita de normativas&nbsp;\" loading=\"lazy\" src=\"https:\/\/no-cache.hubspot.com\/cta\/default\/2009592\/interactive-171915633068.png\" style=\"height: 100%;width: 100%;object-fit: fill\" \/>\n  <\/a>\n<\/div>\n\n","protected":false},"excerpt":{"rendered":"<p><span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">Reading Time: <\/span> <span class=\"rt-time\"> 4<\/span> <span class=\"rt-label rt-postfix\">minutes<\/span><\/span>Cuando, desde la perspectiva de la calidad del aire, se habla de pol\u00edticas de prevenci\u00f3n de riesgos laborales y de mejora del bienestar en los centros de trabajo, suele ponerse el foco en aquellas medidas que se refieren a controlar el ambiente en una situaci\u00f3n de normalidad. Sin embargo, es igual de importante que una<\/p>\n","protected":false},"author":10,"featured_media":4280,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[5],"tags":[],"class_list":["post-4279","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-normativas-de-ventilacion-de-espacios"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.1 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Norma UNE 23585 de control de humos | S&amp;P<\/title>\n<meta name=\"description\" content=\"La Norma UNE 23585 de control de humos es esencial, se fija justo en el factor que m\u00e1s v\u00edctimas provoca: la inhalaci\u00f3n de humo producto de la combusti\u00f3n\" \/>\n<meta name=\"robots\" content=\"noindex, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Norma UNE 23585 de control de humos | S&amp;P\" \/>\n<meta property=\"og:description\" content=\"La Norma UNE 23585 de control de humos es esencial, se fija justo en el factor que m\u00e1s v\u00edctimas provoca: la inhalaci\u00f3n de humo producto de la combusti\u00f3n\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.solerpalau.com\/blog\/2022\/01\/24\/norma-une-23585\/\" \/>\n<meta property=\"og:site_name\" content=\"S&amp;P \/blog no visible\" \/>\n<meta property=\"article:published_time\" content=\"2022-01-24T07:30:56+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.solerpalau.com\/blog\/wp-content\/uploads\/2022\/01\/norma-une-23585-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"627\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"S&amp;P\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t<meta name=\"twitter:data1\" content=\"S&amp;P\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tiempo de lectura\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minutos\" \/>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Norma UNE 23585 de control de humos | S&P","description":"La Norma UNE 23585 de control de humos es esencial, se fija justo en el factor que m\u00e1s v\u00edctimas provoca: la inhalaci\u00f3n de humo producto de la combusti\u00f3n","robots":{"index":"noindex","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"og_locale":"es_ES","og_type":"article","og_title":"Norma UNE 23585 de control de humos | S&P","og_description":"La Norma UNE 23585 de control de humos es esencial, se fija justo en el factor que m\u00e1s v\u00edctimas provoca: la inhalaci\u00f3n de humo producto de la combusti\u00f3n","og_url":"https:\/\/www.solerpalau.com\/blog\/2022\/01\/24\/norma-une-23585\/","og_site_name":"S&amp;P \/blog no visible","article_published_time":"2022-01-24T07:30:56+00:00","og_image":[{"width":1200,"height":627,"url":"https:\/\/www.solerpalau.com\/blog\/wp-content\/uploads\/2022\/01\/norma-une-23585-1.jpg","type":"image\/jpeg"}],"author":"S&amp;P","twitter_card":"summary_large_image","twitter_misc":{"Escrito por":"S&amp;P","Tiempo de lectura":"5 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.solerpalau.com\/blog\/2022\/01\/24\/norma-une-23585\/","url":"https:\/\/www.solerpalau.com\/blog\/2022\/01\/24\/norma-une-23585\/","name":"Norma UNE 23585 de control de humos | S&P","isPartOf":{"@id":"https:\/\/www.solerpalau.com\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.solerpalau.com\/blog\/2022\/01\/24\/norma-une-23585\/#primaryimage"},"image":{"@id":"https:\/\/www.solerpalau.com\/blog\/2022\/01\/24\/norma-une-23585\/#primaryimage"},"thumbnailUrl":"https:\/\/www.solerpalau.com\/blog\/wp-content\/uploads\/2022\/01\/norma-une-23585-1.jpg","datePublished":"2022-01-24T07:30:56+00:00","author":{"@id":"https:\/\/www.solerpalau.com\/blog\/#\/schema\/person\/a649fcc0fccdca5446ea2bc371ad5cb9"},"description":"La Norma UNE 23585 de control de humos es esencial, se fija justo en el factor que m\u00e1s v\u00edctimas provoca: la inhalaci\u00f3n de humo producto de la combusti\u00f3n","breadcrumb":{"@id":"https:\/\/www.solerpalau.com\/blog\/2022\/01\/24\/norma-une-23585\/#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.solerpalau.com\/blog\/2022\/01\/24\/norma-une-23585\/"]}]},{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/www.solerpalau.com\/blog\/2022\/01\/24\/norma-une-23585\/#primaryimage","url":"https:\/\/www.solerpalau.com\/blog\/wp-content\/uploads\/2022\/01\/norma-une-23585-1.jpg","contentUrl":"https:\/\/www.solerpalau.com\/blog\/wp-content\/uploads\/2022\/01\/norma-une-23585-1.jpg","width":1200,"height":627,"caption":"norma une 23585"},{"@type":"BreadcrumbList","@id":"https:\/\/www.solerpalau.com\/blog\/2022\/01\/24\/norma-une-23585\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Portada","item":"https:\/\/www.solerpalau.com\/blog\/"},{"@type":"ListItem","position":2,"name":"Norma UNE 23585 de control de humos"}]},{"@type":"WebSite","@id":"https:\/\/www.solerpalau.com\/blog\/#website","url":"https:\/\/www.solerpalau.com\/blog\/","name":"S&amp;P \/blog no visible","description":"El Blog de ventilaci\u00f3n eficiente para una mejor calidad del aire","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.solerpalau.com\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es"},{"@type":"Person","@id":"https:\/\/www.solerpalau.com\/blog\/#\/schema\/person\/a649fcc0fccdca5446ea2bc371ad5cb9","name":"S&amp;P","image":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/www.solerpalau.com\/blog\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/994644236667321375ba4d21a34a002e2bcfd7b33a114caa4c9dc488ece6c970?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/994644236667321375ba4d21a34a002e2bcfd7b33a114caa4c9dc488ece6c970?s=96&d=mm&r=g","caption":"S&amp;P"},"url":"https:\/\/www.solerpalau.com\/blog\/author\/binaria\/"}]}},"reading_time":"<span class=\"span-reading-time rt-reading-time\"><span class=\"rt-label rt-prefix\"><\/span> <span class=\"rt-time\"> 4<\/span> <span class=\"rt-label rt-postfix\"> min. de lectura<\/span><\/span>","_links":{"self":[{"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/posts\/4279","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/users\/10"}],"replies":[{"embeddable":true,"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/comments?post=4279"}],"version-history":[{"count":0,"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/posts\/4279\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/media\/4280"}],"wp:attachment":[{"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/media?parent=4279"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/categories?post=4279"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/tags?post=4279"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}