{"id":429,"date":"2017-01-25T08:00:08","date_gmt":"2017-01-25T07:00:08","guid":{"rendered":"https:\/\/www.solerpalau.com\/blog\/?p=429"},"modified":"2019-04-15T10:48:43","modified_gmt":"2019-04-15T08:48:43","slug":"demanda-controlada-ventilacion","status":"publish","type":"post","link":"https:\/\/www.solerpalau.com\/blog\/2017\/01\/25\/demanda-controlada-ventilacion\/","title":{"rendered":"Demanda Controlada de Ventilaci\u00f3n (DCV): qu\u00e9 es y cu\u00e1les son sus ventajas"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_76 counter-hierarchy ez-toc-counter ez-toc-custom ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Table of Contents<\/p>\n<span class=\"ez-toc-title-toggle\"><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.solerpalau.com\/blog\/2017\/01\/25\/demanda-controlada-ventilacion\/#%C2%BFQue_es_la_DCV\" >\u00bfQu\u00e9 es la DCV?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.solerpalau.com\/blog\/2017\/01\/25\/demanda-controlada-ventilacion\/#Ventajas_directas_de_la_DCV\" >Ventajas directas de la DCV<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.solerpalau.com\/blog\/2017\/01\/25\/demanda-controlada-ventilacion\/#Ventajas_indirectas\" >Ventajas indirectas<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/www.solerpalau.com\/blog\/2017\/01\/25\/demanda-controlada-ventilacion\/#Reglamento\" >Reglamento<\/a><\/li><\/ul><\/nav><\/div>\n<span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">Reading Time: <\/span> <span class=\"rt-time\"> 4<\/span> <span class=\"rt-label rt-postfix\">minutes<\/span><\/span><p><span style=\"font-weight: 400;\">La energ\u00eda es escasa y cara. Uno de los retos de los fabricantes es conseguir equipos mucho m\u00e1s eficientes que permitan reducir el consumo sin sacrificar las prestaciones.\u00a0<\/span><span style=\"font-weight: 400;\">Por tanto, e<\/span><span style=\"font-weight: 400;\">s importante proponer soluciones encaminadas a contribuir al ahorro energ\u00e9tico en los sistemas de ventilaci\u00f3n.<\/span><\/p>\n<p><!--more--><\/p>\n<h2><span class=\"ez-toc-section\" id=\"%C2%BFQue_es_la_DCV\"><\/span>\u00bfQu\u00e9 es la DCV?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><span style=\"font-weight: 400;\">La Demanda Controlada de Ventilaci\u00f3n (DCV) es una tecnolog\u00eda que provee a los ocupantes de una vivienda o edificio la cantidad adecuada de caudal de aire cuando y donde es necesaria de forma autom\u00e1tica. Por tanto, la creaci\u00f3n de un sistema de ventilaci\u00f3n controla la calidad del aire interior a la vez que genera ahorro energ\u00e9tico.<\/span><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-434\" src=\"https:\/\/www.solerpalau.com\/blog\/wp-content\/uploads\/2017\/01\/Screenshot-2017-01-03-at-12.07.48-PM.png\" alt=\"screenshot-2017-01-03-at-12-07-48-pm\" width=\"650\" height=\"124\" srcset=\"https:\/\/www.solerpalau.com\/blog\/wp-content\/uploads\/2017\/01\/Screenshot-2017-01-03-at-12.07.48-PM.png 650w, https:\/\/www.solerpalau.com\/blog\/wp-content\/uploads\/2017\/01\/Screenshot-2017-01-03-at-12.07.48-PM-600x114.png 600w\" sizes=\"auto, (max-width: 650px) 100vw, 650px\" \/><\/p>\n<p><span style=\"font-weight: 400;\">La DCV tambi\u00e9n permite controlar las prestaciones de la instalaci\u00f3n ajust\u00e1ndola a las necesidades reales en funci\u00f3n de su utilizaci\u00f3n o de las condiciones ambientales de los locales a ventilar. <\/span><\/p>\n<p><span style=\"font-weight: 400;\">Para ello utilizamos ventiladores de bajo consumo (EC Technology) combinados con elementos inteligentes como: <\/span><\/p>\n<ul>\n<li><span style=\"font-weight: 400;\"> Controladores de velocidad, convertidores de frecuencia, compuertas motorizadas, bocas bicaudal <\/span><\/li>\n<li><span style=\"font-weight: 400;\"> Detectores de presencia <\/span><\/li>\n<li><span style=\"font-weight: 400;\"> Sensores de CO2 , temperatura, humedad y calidad de aire (VOC*) <\/span><\/li>\n<li><span style=\"font-weight: 400;\"> Sensores de presi\u00f3n<\/span><\/li>\n<\/ul>\n<p>*<i><span style=\"font-weight: 400;\">Los compuestos org\u00e1nicos vol\u00e1tiles, tambi\u00e9n llamados VOC, son sustancias qu\u00edmicas que contienen carbono y se convierten f\u00e1cilmente en vapores o gases. Junto con el carbono, contienen elementos como hidr\u00f3geno, ox\u00edgeno, fluor, cloro, bromo, azufre o nitr\u00f3geno. En ambientes dom\u00e9sticos o laborales existen numerosas fuentes de VOC como en productos de limpieza, productos de higiene personal, cosm\u00e9ticos, pinturas, pl\u00e1sticos o mobiliario. \u00a0<\/span><\/i><\/p>\n<p>&nbsp;<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Ventajas_directas_de_la_DCV\"><\/span>Ventajas directas de la DCV<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<ul>\n<li style=\"font-weight: 400;\"><b>Ahorro energ\u00e9tico: <\/b><span style=\"font-weight: 400;\">Como se ha dicho con anterioridad, la DCV consigue un sistema de ventilaci\u00f3n que adapta sus prestaciones dependiendo de la ocupaci\u00f3n o condiciones ambientales de la zona. En consecuencia, el consumo del sistema de ventilaci\u00f3n se reduce claramente y tambi\u00e9n las cargas, tanto t\u00e9rmicas como frigor\u00edficas, del sistema de climatizaci\u00f3n.<\/span><\/li>\n<\/ul>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-433\" src=\"https:\/\/www.solerpalau.com\/blog\/wp-content\/uploads\/2017\/01\/Screenshot-2017-01-03-at-12.06.56-PM.png\" alt=\"screenshot-2017-01-03-at-12-06-56-pm\" width=\"536\" height=\"276\" \/><\/p>\n<ul>\n<li style=\"font-weight: 400;\"><b>Reducci\u00f3n factura el\u00e9ctrica:<\/b> <span style=\"font-weight: 400;\">El precio de la energ\u00eda afecta a la competitividad de las empresas y a la econom\u00eda de los particulares. Queda claro que los fabricantes debemos trabajar intensamente para poner en el mercado sistemas cada vez m\u00e1s eficientes que contribuyan a disminuir este impacto econ\u00f3mico.<\/span><\/li>\n<\/ul>\n<ul>\n<li><b>Confort: <\/b><span style=\"font-weight: 400;\">Un entorno laboral sano contribuye a reducir la fatiga y afecciones de los trabajadores. A la vez, favorece a una mayor productividad y reducci\u00f3n del absentismo por enfermedad. Un sistema de ventilaci\u00f3n con tecnolog\u00eda DCV permite controlar la calidad de aire. Esto se consigue mediante una ventilaci\u00f3n \u00f3ptima autom\u00e1tica en cada situaci\u00f3n, evitando concentraciones no recomendables de CO2, humedad, temperatura o VOC. \u00a0<\/span><\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Ventajas_indirectas\"><\/span>Ventajas indirectas<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>&nbsp;<\/p>\n<ul>\n<li><b>Coste total ciclo de vida: <span style=\"font-weight: 400;\">Un ventilador es una m\u00e1quina con una duraci\u00f3n media de 10 a\u00f1os y, como tal, tiene un coste total durante su ciclo de vida que se reparte de la siguiente manera: Inversi\u00f3n 10%, Mantenimiento 5% y Coste de Mantenimiento 85%.<\/span> <span style=\"font-weight: 400;\">Por tanto, la mejora de la eficiencia energ\u00e9tica mediante la DCV afectar\u00e1 de forma indirecta sobre el coste total del ciclo de vida del sistema de ventilaci\u00f3n.<\/span><\/b><\/li>\n<\/ul>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-430\" src=\"https:\/\/www.solerpalau.com\/blog\/wp-content\/uploads\/2017\/01\/Screenshot-2017-01-03-at-12.04.33-PM.png\" alt=\"screenshot-2017-01-03-at-12-04-33-pm\" width=\"518\" height=\"147\" \/><\/p>\n<ul>\n<li style=\"font-weight: 400;\"><b>Vida \u00fatil ventiladores: <\/b><span style=\"font-weight: 400;\">La vida de los motores instalados en los ventiladores que forman un sistema DCV ser\u00e1 mayor al trabajar durante menos horas a m\u00e1ximas prestaciones.<\/span><\/li>\n<\/ul>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-431\" src=\"https:\/\/www.solerpalau.com\/blog\/wp-content\/uploads\/2017\/01\/Screenshot-2017-01-03-at-12.05.09-PM.png\" alt=\"screenshot-2017-01-03-at-12-05-09-pm\" width=\"622\" height=\"81\" srcset=\"https:\/\/www.solerpalau.com\/blog\/wp-content\/uploads\/2017\/01\/Screenshot-2017-01-03-at-12.05.09-PM.png 622w, https:\/\/www.solerpalau.com\/blog\/wp-content\/uploads\/2017\/01\/Screenshot-2017-01-03-at-12.05.09-PM-600x78.png 600w\" sizes=\"auto, (max-width: 622px) 100vw, 622px\" \/><\/p>\n<ul>\n<li><b>Protecci\u00f3n medio ambiente:<\/b><span style=\"font-weight: 400;\"> Reducci\u00f3n emisiones CO2 y adaptaci\u00f3n del consumo a las necesidades reales en cada situaci\u00f3n.<\/span><\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Reglamento\"><\/span>Reglamento<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<h3><b>RITE Y CTE<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">En concreto, en Espa\u00f1a, el RITE (Reglamento de Instalaciones T\u00e9rmicas en los edificios) especifica, en el Cap\u00edtulo II &#8211; Exigencias T\u00e9cnicas, Apartado 12 &#8211; Eficiencia Energ\u00e9tica, Punto <\/span><span style=\"font-weight: 400;\">3 &#8211; Regulaci\u00f3n y Control: <em>\u201clas instalaciones estar\u00e1n dotadas de los sistemas de regulaci\u00f3n y control necesarios para que se puedan mantener las condiciones de dise\u00f1o previstas en los locales climatizados, ajustando, al mismo tiempo, los consumos de energ\u00eda a las variaciones de la demanda, o la interrupci\u00f3n del servicio.\u201d<\/em><\/span><\/p>\n<p>&nbsp;<\/p>\n<h3><b>Dom\u00e9sticas<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">Finalmente, en lo que se refiere a los caudales de aire necesarios seg\u00fan vivienda, existen normativas espec\u00edficas nacionales. En Espa\u00f1a, estos par\u00e1metros est\u00e1n definidos por el C\u00f3digo T\u00e9cnico de la Edificaci\u00f3n (CTE) en su documento b\u00e1sico DB-HS3. <\/span><\/p>\n<p>&nbsp;<\/p>\n<h3><b>Terciarias<\/b><\/h3>\n<p style=\"text-align: left;\"><span style=\"font-weight: 400;\">La normativa nacional aplicable en estos casos es el Reglamento de Instalaci\u00f3nes T\u00e9rmicas en los Edificios (RITE). En funci\u00f3n del uso del edificio o loca, la categor\u00eda de calidad de aire interior (IDA) que se deber\u00e1 alcanzar ser\u00e1, como m\u00ednimo, la siguiente: <\/span><\/p>\n<table>\n<tbody>\n<tr>\n<td><span style=\"font-weight: 400;\">Categor\u00eda<\/span><\/td>\n<td><span style=\"font-weight: 400;\">dm\u00b3\/s por persona<\/span><\/td>\n<td><span style=\"font-weight: 400;\">m\u00b3\/h por persona<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">IDA 1<\/span><\/td>\n<td><span style=\"font-weight: 400;\">20<\/span><\/td>\n<td><span style=\"font-weight: 400;\">72<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">IDA 2<\/span><\/td>\n<td>\n<p style=\"text-align: left;\"><span style=\"font-weight: 400;\">12,5<\/span><\/p>\n<\/td>\n<td style=\"text-align: left;\"><span style=\"font-weight: 400;\">45<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">IDA 3<\/span><\/td>\n<td><span style=\"font-weight: 400;\">8<\/span><\/td>\n<td><span style=\"font-weight: 400;\">28,8<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">IDA 4<\/span><\/td>\n<td><span style=\"font-weight: 400;\">5<\/span><\/td>\n<td><span style=\"font-weight: 400;\">18<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p><i><span style=\"font-weight: 400;\">IDA 1 (aire de \u00f3ptima calidad): hospitales, cl\u00ednicas, laboratorios y guarder\u00edas.<\/span><\/i><\/p>\n<p><i><span style=\"font-weight: 400;\">IDA 2 (aire de buena calidad): oficinas, residencias (locales comunes de hoteles y similares, residencias de ancianos y estudiantes), salas de lectura, museos, aulas de ense\u00f1anza y asimilables y piscinas.<\/span><\/i><\/p>\n<p><i><span style=\"font-weight: 400;\">IDA 3 (aire de calidad media): edificios comerciales, cines, teatros, salones de actos, habitaciones de hoteles, restaurantes, cafeter\u00edas, bares, salas de fiestas, gimnasios, locales para el deporte (salvo piscinas) y salas de ordenadores.<\/span><\/i><\/p>\n<p><i><span style=\"font-weight: 400;\">IDA 4 (aire de baja calidad)<\/span><\/i><\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: center;\">[cta_hubspot id=677]<\/p>\n<p><iframe loading=\"lazy\" title=\"Sistema DCV Monozona\" width=\"500\" height=\"281\" src=\"https:\/\/www.youtube.com\/embed\/p5VObaqtW-k?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe><\/p>\n<p style=\"text-align: center;\">\u00a0<a href=\"https:\/\/www.youtube.com\/watch?v=m5ODBR3uC8g\" target=\"_blank\">V\u00eddeo<\/a> del sistema DCV Multizona<\/p>\n","protected":false},"excerpt":{"rendered":"<p><span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">Reading Time: <\/span> <span class=\"rt-time\"> 4<\/span> <span class=\"rt-label rt-postfix\">minutes<\/span><\/span>La energ\u00eda es escasa y cara. Uno de los retos de los fabricantes es conseguir equipos mucho m\u00e1s eficientes que permitan reducir el consumo sin sacrificar las prestaciones.\u00a0Por tanto, es importante proponer soluciones encaminadas a contribuir al ahorro energ\u00e9tico en los sistemas de ventilaci\u00f3n.<\/p>\n","protected":false},"author":10,"featured_media":678,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[3],"tags":[],"class_list":["post-429","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-sostenibilidad-y-eficiencia-energetica"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.1 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Demanda Controlada de Ventilaci\u00f3n (DCV): qu\u00e9 es y ventajas<\/title>\n<meta name=\"description\" content=\"La Demanda Controlada de Ventilaci\u00f3n es una tecnolog\u00eda que provee a los ocupantes de un edificio la cantidad adecuada de caudal de aire de forma autom\u00e1tica.\" \/>\n<meta name=\"robots\" content=\"noindex, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Demanda Controlada de Ventilaci\u00f3n (DCV): qu\u00e9 es y ventajas\" \/>\n<meta property=\"og:description\" content=\"La Demanda Controlada de Ventilaci\u00f3n es una tecnolog\u00eda que provee a los ocupantes de un edificio la cantidad adecuada de caudal de aire de forma autom\u00e1tica.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.solerpalau.com\/blog\/2017\/01\/25\/demanda-controlada-ventilacion\/\" \/>\n<meta property=\"og:site_name\" content=\"S&amp;P \/blog no visible\" \/>\n<meta property=\"article:published_time\" content=\"2017-01-25T07:00:08+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2019-04-15T08:48:43+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.solerpalau.com\/blog\/wp-content\/uploads\/2017\/01\/iStock-187057001.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"724\" \/>\n\t<meta property=\"og:image:height\" content=\"483\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"S&amp;P\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t<meta name=\"twitter:data1\" content=\"S&amp;P\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tiempo de lectura\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minutos\" \/>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Demanda Controlada de Ventilaci\u00f3n (DCV): qu\u00e9 es y ventajas","description":"La Demanda Controlada de Ventilaci\u00f3n es una tecnolog\u00eda que provee a los ocupantes de un edificio la cantidad adecuada de caudal de aire de forma autom\u00e1tica.","robots":{"index":"noindex","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"og_locale":"es_ES","og_type":"article","og_title":"Demanda Controlada de Ventilaci\u00f3n (DCV): qu\u00e9 es y ventajas","og_description":"La Demanda Controlada de Ventilaci\u00f3n es una tecnolog\u00eda que provee a los ocupantes de un edificio la cantidad adecuada de caudal de aire de forma autom\u00e1tica.","og_url":"https:\/\/www.solerpalau.com\/blog\/2017\/01\/25\/demanda-controlada-ventilacion\/","og_site_name":"S&amp;P \/blog no visible","article_published_time":"2017-01-25T07:00:08+00:00","article_modified_time":"2019-04-15T08:48:43+00:00","og_image":[{"width":724,"height":483,"url":"https:\/\/www.solerpalau.com\/blog\/wp-content\/uploads\/2017\/01\/iStock-187057001.jpg","type":"image\/jpeg"}],"author":"S&amp;P","twitter_card":"summary_large_image","twitter_misc":{"Escrito por":"S&amp;P","Tiempo de lectura":"5 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.solerpalau.com\/blog\/2017\/01\/25\/demanda-controlada-ventilacion\/","url":"https:\/\/www.solerpalau.com\/blog\/2017\/01\/25\/demanda-controlada-ventilacion\/","name":"Demanda Controlada de Ventilaci\u00f3n (DCV): qu\u00e9 es y ventajas","isPartOf":{"@id":"https:\/\/www.solerpalau.com\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.solerpalau.com\/blog\/2017\/01\/25\/demanda-controlada-ventilacion\/#primaryimage"},"image":{"@id":"https:\/\/www.solerpalau.com\/blog\/2017\/01\/25\/demanda-controlada-ventilacion\/#primaryimage"},"thumbnailUrl":"https:\/\/www.solerpalau.com\/blog\/wp-content\/uploads\/2017\/01\/iStock-187057001.jpg","datePublished":"2017-01-25T07:00:08+00:00","dateModified":"2019-04-15T08:48:43+00:00","author":{"@id":"https:\/\/www.solerpalau.com\/blog\/#\/schema\/person\/a649fcc0fccdca5446ea2bc371ad5cb9"},"description":"La Demanda Controlada de Ventilaci\u00f3n es una tecnolog\u00eda que provee a los ocupantes de un edificio la cantidad adecuada de caudal de aire de forma autom\u00e1tica.","breadcrumb":{"@id":"https:\/\/www.solerpalau.com\/blog\/2017\/01\/25\/demanda-controlada-ventilacion\/#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.solerpalau.com\/blog\/2017\/01\/25\/demanda-controlada-ventilacion\/"]}]},{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/www.solerpalau.com\/blog\/2017\/01\/25\/demanda-controlada-ventilacion\/#primaryimage","url":"https:\/\/www.solerpalau.com\/blog\/wp-content\/uploads\/2017\/01\/iStock-187057001.jpg","contentUrl":"https:\/\/www.solerpalau.com\/blog\/wp-content\/uploads\/2017\/01\/iStock-187057001.jpg","width":724,"height":483,"caption":"demanda controlada ventilacion"},{"@type":"BreadcrumbList","@id":"https:\/\/www.solerpalau.com\/blog\/2017\/01\/25\/demanda-controlada-ventilacion\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Portada","item":"https:\/\/www.solerpalau.com\/blog\/"},{"@type":"ListItem","position":2,"name":"Demanda Controlada de Ventilaci\u00f3n (DCV): qu\u00e9 es y cu\u00e1les son sus ventajas"}]},{"@type":"WebSite","@id":"https:\/\/www.solerpalau.com\/blog\/#website","url":"https:\/\/www.solerpalau.com\/blog\/","name":"S&amp;P \/blog no visible","description":"El Blog de ventilaci\u00f3n eficiente para una mejor calidad del aire","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.solerpalau.com\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es"},{"@type":"Person","@id":"https:\/\/www.solerpalau.com\/blog\/#\/schema\/person\/a649fcc0fccdca5446ea2bc371ad5cb9","name":"S&amp;P","image":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/www.solerpalau.com\/blog\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/994644236667321375ba4d21a34a002e2bcfd7b33a114caa4c9dc488ece6c970?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/994644236667321375ba4d21a34a002e2bcfd7b33a114caa4c9dc488ece6c970?s=96&d=mm&r=g","caption":"S&amp;P"},"url":"https:\/\/www.solerpalau.com\/blog\/author\/binaria\/"}]}},"reading_time":"<span class=\"span-reading-time rt-reading-time\"><span class=\"rt-label rt-prefix\"><\/span> <span class=\"rt-time\"> 4<\/span> <span class=\"rt-label rt-postfix\"> min. de lectura<\/span><\/span>","_links":{"self":[{"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/posts\/429","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/users\/10"}],"replies":[{"embeddable":true,"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/comments?post=429"}],"version-history":[{"count":11,"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/posts\/429\/revisions"}],"predecessor-version":[{"id":704,"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/posts\/429\/revisions\/704"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/media\/678"}],"wp:attachment":[{"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/media?parent=429"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/categories?post=429"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/tags?post=429"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}