{"id":841,"date":"2017-03-24T08:00:15","date_gmt":"2017-03-24T07:00:15","guid":{"rendered":"https:\/\/www.solerpalau.com\/blog\/?p=841"},"modified":"2019-04-15T10:48:20","modified_gmt":"2019-04-15T08:48:20","slug":"cte-db-hs3-calidad-aire-interior","status":"publish","type":"post","link":"https:\/\/www.solerpalau.com\/blog\/2017\/03\/24\/cte-db-hs3-calidad-aire-interior\/","title":{"rendered":"CTE DB HS3, la secci\u00f3n sobre la calidad del aire interior"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_76 counter-hierarchy ez-toc-counter ez-toc-custom ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Table of Contents<\/p>\n<span class=\"ez-toc-title-toggle\"><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.solerpalau.com\/blog\/2017\/03\/24\/cte-db-hs3-calidad-aire-interior\/#%C2%BFQue_especifica_el_CTE_DB_HS3\" >\u00bfQu\u00e9 especifica el CTE DB HS3?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.solerpalau.com\/blog\/2017\/03\/24\/cte-db-hs3-calidad-aire-interior\/#%C2%BFQue_sistema_de_extraccion_utilizar\" >\u00bfQu\u00e9 sistema de extracci\u00f3n utilizar?<\/a><\/li><\/ul><\/nav><\/div>\n<span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">Reading Time: <\/span> <span class=\"rt-time\"> 3<\/span> <span class=\"rt-label rt-postfix\">minutes<\/span><\/span><p><span style=\"font-weight: 400;\">La secci\u00f3n HS 3 del CTE se refiere a la calidad del aire interior y tiene aplicaci\u00f3n b\u00e1sicamente en edificios de viviendas, almacenes de residuos, trasteros y aparcamientos o garajes. <\/span><\/p>\n<p><span style=\"font-weight: 400;\">El objetivo de esta secci\u00f3n no es m\u00e1s que la de conseguir eliminar gran parte de los contaminantes presentes en el aire interior, garantizando una \u00f3ptima calidad del mismo y evitando la aparici\u00f3n en la vivienda de posteriores problemas debido a la falta de ventilaci\u00f3n, como por ejemplo, las humedades.<!--more--><\/span><\/p>\n<p style=\"text-align: center;\"><span data-sheets-value=\"{&quot;1&quot;:2,&quot;2&quot;:&quot;[cta_hubspot id=33]&quot;}\" data-sheets-userformat=\"{&quot;2&quot;:14851,&quot;3&quot;:{&quot;1&quot;:0},&quot;4&quot;:{&quot;1&quot;:2,&quot;2&quot;:16777215},&quot;12&quot;:0,&quot;14&quot;:{&quot;1&quot;:2,&quot;2&quot;:4473924},&quot;15&quot;:&quot;Consolas, Monaco, monospace&quot;,&quot;16&quot;:8}\">[cta_hubspot id=33]<\/span><\/p>\n<p>&nbsp;<\/p>\n<h2><span class=\"ez-toc-section\" id=\"%C2%BFQue_especifica_el_CTE_DB_HS3\"><\/span>\u00bfQu\u00e9 especifica el CTE DB HS3?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><span style=\"font-weight: 400;\">El CTE DB HS 3 especifica el caudal de ventilaci\u00f3n adem\u00e1s de otros detalles de la instalaci\u00f3n. Para garantizar que el aire viciado no se distribuya desde los locales m\u00e1s contaminados (habitualmente locales h\u00famedos) hacia los locales secos (normalmente con menor contaminaci\u00f3n), la extracci\u00f3n de dicho aire se realizar\u00e1 siempre a trav\u00e9s de bocas o rejillas situadas en los locales h\u00famedos, como ser\u00edan el ba\u00f1o, la cocina o el aseo. La entrada de aire exterior se realizar\u00e1 a trav\u00e9s de aireadores situados en los locales secos, como podr\u00edan ser el comedor y las habitaciones. La situaci\u00f3n y colocaci\u00f3n tanto de los aireadores como de las bocas de extracci\u00f3n quedan especificadas en la misma normativa.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">El caudal que se debe extraer y aportar debe estar lo m\u00e1s compensado posible, evitando as\u00ed problemas generados por corrientes debido a la sobrepresi\u00f3n o a la depresi\u00f3n excesiva de la vivienda. No obstante, siempre se debe cumplir con los caudales m\u00ednimos exigidos por la normativa, que son los siguientes:<\/span><\/p>\n<table>\n<tbody>\n<tr>\n<td><span style=\"font-weight: 400;\">\u00a0<\/span><\/td>\n<td colspan=\"3\"><b>Caudal de ventilaci\u00f3n m\u00ednimo exigido q<\/b><b>v<\/b><b> en l\/s<\/b><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">\u00a0<\/span><\/td>\n<td><b>Por ocupante<\/b><\/td>\n<td><b>Por m<\/b><b>2<\/b><b> \u00fatil<\/b><\/td>\n<td><b>En funci\u00f3n de otros par\u00e1metros<\/b><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Dormitorios<\/span><\/td>\n<td><span style=\"font-weight: 400;\">5<\/span><\/td>\n<td><span style=\"font-weight: 400;\">\u00a0<\/span><\/td>\n<td><span style=\"font-weight: 400;\">\u00a0<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Salas de estar y comedores<\/span><\/td>\n<td><span style=\"font-weight: 400;\">3<\/span><\/td>\n<td><span style=\"font-weight: 400;\">\u00a0<\/span><\/td>\n<td><span style=\"font-weight: 400;\">\u00a0<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Aseos y cuartos de ba\u00f1o<\/span><\/td>\n<td><span style=\"font-weight: 400;\">\u00a0<\/span><\/td>\n<td><span style=\"font-weight: 400;\">\u00a0<\/span><\/td>\n<td><span style=\"font-weight: 400;\">15 por local<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Cocinas<\/span><\/td>\n<td><span style=\"font-weight: 400;\">\u00a0<\/span><\/td>\n<td><span style=\"font-weight: 400;\">2<\/span><\/td>\n<td><span style=\"font-weight: 400;\">\u00a0<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">\u00a0<\/span><\/td>\n<td><span style=\"font-weight: 400;\">\u00a0<\/span><\/td>\n<td><span style=\"font-weight: 400;\">\u00a0<\/span><\/td>\n<td><span style=\"font-weight: 400;\">50 por local <\/span><span style=\"font-weight: 400;\">(1)<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Trasteros y sus zonas comunes<\/span><\/td>\n<td><span style=\"font-weight: 400;\">\u00a0<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0,7<\/span><\/td>\n<td><span style=\"font-weight: 400;\">\u00a0<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Aparcamientos y garajes<\/span><\/td>\n<td><span style=\"font-weight: 400;\">\u00a0<\/span><\/td>\n<td><span style=\"font-weight: 400;\">\u00a0<\/span><\/td>\n<td><span style=\"font-weight: 400;\">120 por plaza<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Almacenes de residuos<\/span><\/td>\n<td><span style=\"font-weight: 400;\">\u00a0<\/span><\/td>\n<td><span style=\"font-weight: 400;\">10<\/span><\/td>\n<td><span style=\"font-weight: 400;\">\u00a0<\/span><\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\"><span style=\"font-weight: 400;\">(1) Este es el caudal correspondiente a la ventilaci\u00f3n adicional espec\u00edfica de la cocina<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<h2><span class=\"ez-toc-section\" id=\"%C2%BFQue_sistema_de_extraccion_utilizar\"><\/span>\u00bfQu\u00e9 sistema de extracci\u00f3n utilizar?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><span style=\"font-weight: 400;\">Las bocas o aberturas de extracci\u00f3n deben conectarse a conductos de extracci\u00f3n. Un mismo conducto de extracci\u00f3n puede ser compartido por aseos, ba\u00f1os y cocinas. <\/span><\/p>\n<p><span style=\"font-weight: 400;\">Cada conducto de extracci\u00f3n deber\u00e1 disponer de un aspirador mec\u00e1nico o ventilador situado despu\u00e9s de la \u00faltima abertura de extracci\u00f3n en el sentido del flujo del aire, pudiendo varios conductos compartir un mismo ventilador, a excepci\u00f3n de los conductos de los garajes en los que se puede exigir m\u00e1s de una red. La velocidad m\u00e1xima de paso del aire a trav\u00e9s de los conductos interiores de la vivienda es de 4 m\/s, mientras que cuando los conductos son exteriores a la misma se permite alcanzar una velocidad de 6,67 m\/s. <\/span><\/p>\n<p><span style=\"font-weight: 400;\">El sistema m\u00e1s com\u00fan de extracci\u00f3n <a href=\"https:\/\/www.solerpalau.com\/blog\/ventilacion-mecanica\/\" target=\"_blank\">mec\u00e1nica<\/a> se denomina caudal constante y es el que garantiza la extracci\u00f3n de los caudales exactos marcados por el CTE. Otro sistema permitido por el CTE es el de doble flujo, donde se garantiza la extracci\u00f3n del caudal m\u00ednimo prestablecido, as\u00ed como la aportaci\u00f3n de aire del exterior de forma mec\u00e1nica, en vez de por depresi\u00f3n como se realiza en el sistema de caudal constante de simple flujo. La ventaja principal de estos sistemas es la inclusi\u00f3n de un n\u00facleo de recuperaci\u00f3n de calor, mediante el cual se consigue un intercambio t\u00e9rmico entre el caudal de aire viciado y el caudal de aire de entrada, consiguiendo enfriar o calentar el aire de aportaci\u00f3n de forma gratuita hasta un cierto grado, dependiendo de la eficiencia del n\u00facleo de recuperaci\u00f3n. <\/span><\/p>\n<p><span style=\"font-weight: 400;\">Finalmente, existe un \u00faltimo sistema, denominado de caudal variable o higrorregulable, que establece un caudal de ventilaci\u00f3n m\u00ednimo seg\u00fan las exigencias de humedad relativa que tenga la vivienda en un momento determinado. De este modo, se consigue un ahorro en el consumo de los ventiladores gracias a la regulaci\u00f3n del caudal de ventilaci\u00f3n. Para garantizar que el sistema cumple con las exigencias del <a href=\"https:\/\/www.solerpalau.com\/blog\/cte-ventilacion-exigencias-del-cte-la-calidad-del-aire-la-vivienda\/\" target=\"_blank\">CTE<\/a>, el fabricante de la soluci\u00f3n de ventilaci\u00f3n puede disponer del Documento de Idoneidad T\u00e9cnica (DIT), donde se especifica el ahorro obtenido gracias a este sistema, as\u00ed como las bocas de extracci\u00f3n, aireadores y ventilador id\u00f3neos para cada tipo de vivienda.<\/span><br \/>\n<span data-sheets-value=\"{&quot;1&quot;:2,&quot;2&quot;:&quot;[cta_hubspot id=122]&quot;}\" data-sheets-userformat=\"{&quot;2&quot;:14851,&quot;3&quot;:{&quot;1&quot;:0},&quot;4&quot;:{&quot;1&quot;:2,&quot;2&quot;:16777215},&quot;12&quot;:0,&quot;14&quot;:{&quot;1&quot;:2,&quot;2&quot;:4473924},&quot;15&quot;:&quot;Consolas, Monaco, monospace&quot;,&quot;16&quot;:8}\">[cta_hubspot id=122]<\/span><\/p>\n","protected":false},"excerpt":{"rendered":"<p><span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">Reading Time: <\/span> <span class=\"rt-time\"> 3<\/span> <span class=\"rt-label rt-postfix\">minutes<\/span><\/span>La secci\u00f3n HS 3 del CTE se refiere a la calidad del aire interior y tiene aplicaci\u00f3n b\u00e1sicamente en edificios de viviendas, almacenes de residuos, trasteros y aparcamientos o garajes. El objetivo de esta secci\u00f3n no es m\u00e1s que la de conseguir eliminar gran parte de los contaminantes presentes en el aire interior, garantizando una<\/p>\n","protected":false},"author":10,"featured_media":842,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[5],"tags":[],"class_list":["post-841","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-normativas-de-ventilacion-de-espacios"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.1 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>CTE DB HS3, la secci\u00f3n sobre la calidad del aire interior<\/title>\n<meta name=\"description\" content=\"La secci\u00f3n HS 3 del CTE se refiere a la calidad del aire interior y tiene aplicaci\u00f3n en viviendas, almacenes de residuos, trasteros y aparcamientos.\" \/>\n<meta name=\"robots\" content=\"noindex, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"CTE DB HS3, la secci\u00f3n sobre la calidad del aire interior\" \/>\n<meta property=\"og:description\" content=\"La secci\u00f3n HS 3 del CTE se refiere a la calidad del aire interior y tiene aplicaci\u00f3n en viviendas, almacenes de residuos, trasteros y aparcamientos.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.solerpalau.com\/blog\/2017\/03\/24\/cte-db-hs3-calidad-aire-interior\/\" \/>\n<meta property=\"og:site_name\" content=\"S&amp;P \/blog no visible\" \/>\n<meta property=\"article:published_time\" content=\"2017-03-24T07:00:15+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2019-04-15T08:48:20+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.solerpalau.com\/blog\/wp-content\/uploads\/2017\/03\/iStock-521304774.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"724\" \/>\n\t<meta property=\"og:image:height\" content=\"483\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"S&amp;P\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t<meta name=\"twitter:data1\" content=\"S&amp;P\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tiempo de lectura\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutos\" \/>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"CTE DB HS3, la secci\u00f3n sobre la calidad del aire interior","description":"La secci\u00f3n HS 3 del CTE se refiere a la calidad del aire interior y tiene aplicaci\u00f3n en viviendas, almacenes de residuos, trasteros y aparcamientos.","robots":{"index":"noindex","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"og_locale":"es_ES","og_type":"article","og_title":"CTE DB HS3, la secci\u00f3n sobre la calidad del aire interior","og_description":"La secci\u00f3n HS 3 del CTE se refiere a la calidad del aire interior y tiene aplicaci\u00f3n en viviendas, almacenes de residuos, trasteros y aparcamientos.","og_url":"https:\/\/www.solerpalau.com\/blog\/2017\/03\/24\/cte-db-hs3-calidad-aire-interior\/","og_site_name":"S&amp;P \/blog no visible","article_published_time":"2017-03-24T07:00:15+00:00","article_modified_time":"2019-04-15T08:48:20+00:00","og_image":[{"width":724,"height":483,"url":"https:\/\/www.solerpalau.com\/blog\/wp-content\/uploads\/2017\/03\/iStock-521304774.jpg","type":"image\/jpeg"}],"author":"S&amp;P","twitter_card":"summary_large_image","twitter_misc":{"Escrito por":"S&amp;P","Tiempo de lectura":"4 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.solerpalau.com\/blog\/2017\/03\/24\/cte-db-hs3-calidad-aire-interior\/","url":"https:\/\/www.solerpalau.com\/blog\/2017\/03\/24\/cte-db-hs3-calidad-aire-interior\/","name":"CTE DB HS3, la secci\u00f3n sobre la calidad del aire interior","isPartOf":{"@id":"https:\/\/www.solerpalau.com\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.solerpalau.com\/blog\/2017\/03\/24\/cte-db-hs3-calidad-aire-interior\/#primaryimage"},"image":{"@id":"https:\/\/www.solerpalau.com\/blog\/2017\/03\/24\/cte-db-hs3-calidad-aire-interior\/#primaryimage"},"thumbnailUrl":"https:\/\/www.solerpalau.com\/blog\/wp-content\/uploads\/2017\/03\/iStock-521304774.jpg","datePublished":"2017-03-24T07:00:15+00:00","dateModified":"2019-04-15T08:48:20+00:00","author":{"@id":"https:\/\/www.solerpalau.com\/blog\/#\/schema\/person\/a649fcc0fccdca5446ea2bc371ad5cb9"},"description":"La secci\u00f3n HS 3 del CTE se refiere a la calidad del aire interior y tiene aplicaci\u00f3n en viviendas, almacenes de residuos, trasteros y aparcamientos.","breadcrumb":{"@id":"https:\/\/www.solerpalau.com\/blog\/2017\/03\/24\/cte-db-hs3-calidad-aire-interior\/#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.solerpalau.com\/blog\/2017\/03\/24\/cte-db-hs3-calidad-aire-interior\/"]}]},{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/www.solerpalau.com\/blog\/2017\/03\/24\/cte-db-hs3-calidad-aire-interior\/#primaryimage","url":"https:\/\/www.solerpalau.com\/blog\/wp-content\/uploads\/2017\/03\/iStock-521304774.jpg","contentUrl":"https:\/\/www.solerpalau.com\/blog\/wp-content\/uploads\/2017\/03\/iStock-521304774.jpg","width":724,"height":483,"caption":"cte db hs3"},{"@type":"BreadcrumbList","@id":"https:\/\/www.solerpalau.com\/blog\/2017\/03\/24\/cte-db-hs3-calidad-aire-interior\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Portada","item":"https:\/\/www.solerpalau.com\/blog\/"},{"@type":"ListItem","position":2,"name":"CTE DB HS3, la secci\u00f3n sobre la calidad del aire interior"}]},{"@type":"WebSite","@id":"https:\/\/www.solerpalau.com\/blog\/#website","url":"https:\/\/www.solerpalau.com\/blog\/","name":"S&amp;P \/blog no visible","description":"El Blog de ventilaci\u00f3n eficiente para una mejor calidad del aire","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.solerpalau.com\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es"},{"@type":"Person","@id":"https:\/\/www.solerpalau.com\/blog\/#\/schema\/person\/a649fcc0fccdca5446ea2bc371ad5cb9","name":"S&amp;P","image":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/www.solerpalau.com\/blog\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/994644236667321375ba4d21a34a002e2bcfd7b33a114caa4c9dc488ece6c970?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/994644236667321375ba4d21a34a002e2bcfd7b33a114caa4c9dc488ece6c970?s=96&d=mm&r=g","caption":"S&amp;P"},"url":"https:\/\/www.solerpalau.com\/blog\/author\/binaria\/"}]}},"reading_time":"<span class=\"span-reading-time rt-reading-time\"><span class=\"rt-label rt-prefix\"><\/span> <span class=\"rt-time\"> 3<\/span> <span class=\"rt-label rt-postfix\"> min. de lectura<\/span><\/span>","_links":{"self":[{"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/posts\/841","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/users\/10"}],"replies":[{"embeddable":true,"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/comments?post=841"}],"version-history":[{"count":4,"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/posts\/841\/revisions"}],"predecessor-version":[{"id":856,"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/posts\/841\/revisions\/856"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/media\/842"}],"wp:attachment":[{"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/media?parent=841"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/categories?post=841"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/tags?post=841"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}