{"id":890,"date":"2017-04-10T08:00:41","date_gmt":"2017-04-10T06:00:41","guid":{"rendered":"https:\/\/www.solerpalau.com\/blog\/?p=890"},"modified":"2019-04-15T10:48:19","modified_gmt":"2019-04-15T08:48:19","slug":"ventilacion-nave-fundicion-aluminio","status":"publish","type":"post","link":"https:\/\/www.solerpalau.com\/blog\/2017\/04\/10\/ventilacion-nave-fundicion-aluminio\/","title":{"rendered":"Ventilaci\u00f3n de una nave de fundici\u00f3n de aluminio: caso pr\u00e1ctico"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_76 counter-hierarchy ez-toc-counter ez-toc-custom ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Table of Contents<\/p>\n<span class=\"ez-toc-title-toggle\"><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.solerpalau.com\/blog\/2017\/04\/10\/ventilacion-nave-fundicion-aluminio\/#1_Objeto_del_informe\" >1. Objeto del informe<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.solerpalau.com\/blog\/2017\/04\/10\/ventilacion-nave-fundicion-aluminio\/#2_Bases_de_calculo\" >2. Bases de c\u00e1lculo<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.solerpalau.com\/blog\/2017\/04\/10\/ventilacion-nave-fundicion-aluminio\/#3_Consideraciones_a_tener_en_cuenta\" >3. Consideraciones a tener en cuenta<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/www.solerpalau.com\/blog\/2017\/04\/10\/ventilacion-nave-fundicion-aluminio\/#4_Instalacion_propuesta\" >4. Instalaci\u00f3n propuesta<\/a><\/li><\/ul><\/nav><\/div>\n<span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">Reading Time: <\/span> <span class=\"rt-time\"> 3<\/span> <span class=\"rt-label rt-postfix\">minutes<\/span><\/span><h2><span class=\"ez-toc-section\" id=\"1_Objeto_del_informe\"><\/span>1. Objeto del informe<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Determinar el caudal y sistema adecuado para la ventilaci\u00f3n de una nave de fundici\u00f3n de aluminio.<\/p>\n<p><!--more--><\/p>\n<h2><span class=\"ez-toc-section\" id=\"2_Bases_de_calculo\"><\/span>2. Bases de c\u00e1lculo<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Se trata de una nave de planta rectangular de 74&#215;36 m y una altura media de 12 m. En la parte derecha de la nave hay un almac\u00e9n con 2 grandes portones de acceso que se encuentran normalmente abiertos.<\/p>\n<p>Las m\u00e1quinas ubicadas en la parte izquierda disponen de un sistema de captaci\u00f3n localizada que no consigue captar los humos desprendidos en el proceso de inyecci\u00f3n y 2 extractores axiales murales que resultan insuficientes.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-894\" src=\"https:\/\/www.solerpalau.com\/blog\/wp-content\/uploads\/2017\/04\/Screenshot-2017-04-08-at-6.43.36-PM.png\" alt=\"ventilacion nave fundicion\" width=\"674\" height=\"402\" srcset=\"https:\/\/www.solerpalau.com\/blog\/wp-content\/uploads\/2017\/04\/Screenshot-2017-04-08-at-6.43.36-PM.png 674w, https:\/\/www.solerpalau.com\/blog\/wp-content\/uploads\/2017\/04\/Screenshot-2017-04-08-at-6.43.36-PM-600x358.png 600w\" sizes=\"auto, (max-width: 674px) 100vw, 674px\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>Las 4 m\u00e1quinas del fondo no disponen de sistema de extracci\u00f3n. A pesar de tener los sistemas de extracci\u00f3n actuales en funcionamiento y los 2 portones laterales abiertos, se acumula una cantidad de humo considerable. Se solicita contemplar un sistema de renovaci\u00f3n ambiental por la cubierta.<\/p>\n<p>&nbsp;<\/p>\n<h2><span class=\"ez-toc-section\" id=\"3_Consideraciones_a_tener_en_cuenta\"><\/span>3. Consideraciones a tener en cuenta<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Por lo general, un sistema de captaci\u00f3n localizada situada adecuadamente, puede ser m\u00e1s efectiva que un sistema de ventilaci\u00f3n general.<\/p>\n<p>El sistema de captaci\u00f3n existente presenta un nulo efecto de aspiraci\u00f3n sobre el humo emitido que asciende a una velocidad considerable y su salida se concentra en el frontal del cerramiento del brazo articulado, por lo que es presumible que, reubicando el sistema de captaci\u00f3n y cambiando el tipo de extractor por otros que minimicen la acumulaci\u00f3n de suciedad en sus \u00e1labes, no se pierda tanto rendimiento.<\/p>\n<p>&nbsp;<\/p>\n<h2><span class=\"ez-toc-section\" id=\"4_Instalacion_propuesta\"><\/span>4. Instalaci\u00f3n propuesta<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<h3>4.1. Ventilaci\u00f3n general<\/h3>\n<p>A la vista de la cantidad de humo presente en la zona de producci\u00f3n se aconseja practicar al menos 15 renovaciones\/hora del volumen de la zona de producci\u00f3n, descontando la zona de almac\u00e9n que quedar\u00e1 igualmente barrida gracias a la disposici\u00f3n de entradas de aire (los portones) y los puntos de extracci\u00f3n, con una superficie de 1.548 m2 por lo que el caudal ser\u00e1 de<\/p>\n<p style=\"padding-left: 30px;\">Q = (1.548 x 12) x 15 = 278.640 m3 \/h<\/p>\n<p>Para ello y visto el movimiento que tiene el humo en la actualidad, se propone instalar sobre la vertical del humo generado (que no sobre el centro de las 6 m\u00e1quinas, ya que se puede observar claramente la vertical ascendente que sigue el humo) por cada una de las m\u00e1quinas de inyecci\u00f3n de la parte izquierda, un extractor centr\u00edfugo de tejado de \u00e1labes hacia atr\u00e1s y motor fuera del flujo del aire extra\u00eddo tipo CTHT\/6-710 m\u00e1s un sexto extractor en la zona entre m\u00e1quinas, para asegurar una mayor renovaci\u00f3n ambiental, junto con las bases inclinadas BI-11 que se construyen a medida, para compensar la pendiente de la cubierta, por lo que se requiere conocer la distancia entre correas y la pendiente de la cubierta.<\/p>\n<p>En la zona del fondo (zamak-magnesio) se montar\u00e1n 4 unidades, tambi\u00e9n buscando la vertical del humo, del tipo CTHT\/6-630 junto con las mismas bases inclinadas BI-11. Se prev\u00e9 que el aire de ventilaci\u00f3n necesario entre a trav\u00e9s de los portones actuales ubicados en la parte derecha y que adem\u00e1s aseguran un correcto barrido del aire del recinto.<\/p>\n<h3>4.2 Captaci\u00f3n localizada<\/h3>\n<p>Para un c\u00e1lculo exacto del caudal requerido, ser\u00eda necesario tener las dimensiones precisas del cerramiento del brazo articulado por cuya parte superior del frontal abierto se escapa el humo.<\/p>\n<p>Estimando que pudiese tener una anchura de 1 m y una altura de 2 m, se deber\u00eda montar una campana de 1&#215;1 m adosada a la parte superior de dicho cerramiento.<\/p>\n<p>Ser\u00eda necesario un caudal de 4.000 m3 \/h por punto, y deber\u00eda estar conectada a un conducto de 250 de di\u00e1metro y al extractor CMRT\/2-351 2.2 kW Especial (se propone que sea con trampilla de inspecci\u00f3n y limpieza, purga en la parte inferior m\u00e1s ret\u00e9n en el eje) y los correspondientes accesorios brida de aspiraci\u00f3n KRBA-250 y KRBI-280&#215;200. Se descargar\u00eda al conducto general ya existente para evacuaci\u00f3n de humos.<\/p>\n<p>Dado el escaso recorrido de la instalaci\u00f3n, se debe verificar que la intensidad absorbida es igual o inferior a la indicada en la placa de caracter\u00edsticas. Se aconseja realizar al menos una instalaci\u00f3n como la propuesta en una de las m\u00e1quinas, para valorar la eficiencia de la captaci\u00f3n de humos y evitar hacer extracciones innecesarias en la cubierta.<\/p>\n<p>Consulta el caso pr\u00e1ctico completo <a href=\"http:\/\/www.solerpalau.es\/media\/casos\/cp48.pdf\" target=\"_blank\">Ventilaci\u00f3n de una nave de fundici\u00f3n de aluminio<\/a>, d\u00f3nde se incluyen los productos y accesorios recomendados.<\/p>\n","protected":false},"excerpt":{"rendered":"<p><span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">Reading Time: <\/span> <span class=\"rt-time\"> 3<\/span> <span class=\"rt-label rt-postfix\">minutes<\/span><\/span>1. Objeto del informe Determinar el caudal y sistema adecuado para la ventilaci\u00f3n de una nave de fundici\u00f3n de aluminio.<\/p>\n","protected":false},"author":10,"featured_media":891,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[9],"tags":[],"class_list":["post-890","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-casos-practicos"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.1 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Ventilaci\u00f3n de una nave de fundici\u00f3n de aluminio: caso pr\u00e1ctico<\/title>\n<meta name=\"description\" content=\"Para un c\u00e1lculo exacto del caudal requerido, es necesario tener las dimensiones precisas del cerramiento del brazo articulado por el que se escapa el humo.\" \/>\n<meta name=\"robots\" content=\"noindex, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Ventilaci\u00f3n de una nave de fundici\u00f3n de aluminio: caso pr\u00e1ctico\" \/>\n<meta property=\"og:description\" content=\"Para un c\u00e1lculo exacto del caudal requerido, es necesario tener las dimensiones precisas del cerramiento del brazo articulado por el que se escapa el humo.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.solerpalau.com\/blog\/2017\/04\/10\/ventilacion-nave-fundicion-aluminio\/\" \/>\n<meta property=\"og:site_name\" content=\"S&amp;P \/blog no visible\" \/>\n<meta property=\"article:published_time\" content=\"2017-04-10T06:00:41+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2019-04-15T08:48:19+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.solerpalau.com\/blog\/wp-content\/uploads\/2017\/04\/iStock-178579420.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"724\" \/>\n\t<meta property=\"og:image:height\" content=\"483\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"S&amp;P\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t<meta name=\"twitter:data1\" content=\"S&amp;P\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tiempo de lectura\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutos\" \/>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Ventilaci\u00f3n de una nave de fundici\u00f3n de aluminio: caso pr\u00e1ctico","description":"Para un c\u00e1lculo exacto del caudal requerido, es necesario tener las dimensiones precisas del cerramiento del brazo articulado por el que se escapa el humo.","robots":{"index":"noindex","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"og_locale":"es_ES","og_type":"article","og_title":"Ventilaci\u00f3n de una nave de fundici\u00f3n de aluminio: caso pr\u00e1ctico","og_description":"Para un c\u00e1lculo exacto del caudal requerido, es necesario tener las dimensiones precisas del cerramiento del brazo articulado por el que se escapa el humo.","og_url":"https:\/\/www.solerpalau.com\/blog\/2017\/04\/10\/ventilacion-nave-fundicion-aluminio\/","og_site_name":"S&amp;P \/blog no visible","article_published_time":"2017-04-10T06:00:41+00:00","article_modified_time":"2019-04-15T08:48:19+00:00","og_image":[{"width":724,"height":483,"url":"https:\/\/www.solerpalau.com\/blog\/wp-content\/uploads\/2017\/04\/iStock-178579420.jpg","type":"image\/jpeg"}],"author":"S&amp;P","twitter_card":"summary_large_image","twitter_misc":{"Escrito por":"S&amp;P","Tiempo de lectura":"4 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.solerpalau.com\/blog\/2017\/04\/10\/ventilacion-nave-fundicion-aluminio\/","url":"https:\/\/www.solerpalau.com\/blog\/2017\/04\/10\/ventilacion-nave-fundicion-aluminio\/","name":"Ventilaci\u00f3n de una nave de fundici\u00f3n de aluminio: caso pr\u00e1ctico","isPartOf":{"@id":"https:\/\/www.solerpalau.com\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.solerpalau.com\/blog\/2017\/04\/10\/ventilacion-nave-fundicion-aluminio\/#primaryimage"},"image":{"@id":"https:\/\/www.solerpalau.com\/blog\/2017\/04\/10\/ventilacion-nave-fundicion-aluminio\/#primaryimage"},"thumbnailUrl":"https:\/\/www.solerpalau.com\/blog\/wp-content\/uploads\/2017\/04\/iStock-178579420.jpg","datePublished":"2017-04-10T06:00:41+00:00","dateModified":"2019-04-15T08:48:19+00:00","author":{"@id":"https:\/\/www.solerpalau.com\/blog\/#\/schema\/person\/a649fcc0fccdca5446ea2bc371ad5cb9"},"description":"Para un c\u00e1lculo exacto del caudal requerido, es necesario tener las dimensiones precisas del cerramiento del brazo articulado por el que se escapa el humo.","breadcrumb":{"@id":"https:\/\/www.solerpalau.com\/blog\/2017\/04\/10\/ventilacion-nave-fundicion-aluminio\/#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.solerpalau.com\/blog\/2017\/04\/10\/ventilacion-nave-fundicion-aluminio\/"]}]},{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/www.solerpalau.com\/blog\/2017\/04\/10\/ventilacion-nave-fundicion-aluminio\/#primaryimage","url":"https:\/\/www.solerpalau.com\/blog\/wp-content\/uploads\/2017\/04\/iStock-178579420.jpg","contentUrl":"https:\/\/www.solerpalau.com\/blog\/wp-content\/uploads\/2017\/04\/iStock-178579420.jpg","width":724,"height":483,"caption":"ventilacion nave fundicion aluminio"},{"@type":"BreadcrumbList","@id":"https:\/\/www.solerpalau.com\/blog\/2017\/04\/10\/ventilacion-nave-fundicion-aluminio\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Portada","item":"https:\/\/www.solerpalau.com\/blog\/"},{"@type":"ListItem","position":2,"name":"Ventilaci\u00f3n de una nave de fundici\u00f3n de aluminio: caso pr\u00e1ctico"}]},{"@type":"WebSite","@id":"https:\/\/www.solerpalau.com\/blog\/#website","url":"https:\/\/www.solerpalau.com\/blog\/","name":"S&amp;P \/blog no visible","description":"El Blog de ventilaci\u00f3n eficiente para una mejor calidad del aire","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.solerpalau.com\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es"},{"@type":"Person","@id":"https:\/\/www.solerpalau.com\/blog\/#\/schema\/person\/a649fcc0fccdca5446ea2bc371ad5cb9","name":"S&amp;P","image":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/www.solerpalau.com\/blog\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/994644236667321375ba4d21a34a002e2bcfd7b33a114caa4c9dc488ece6c970?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/994644236667321375ba4d21a34a002e2bcfd7b33a114caa4c9dc488ece6c970?s=96&d=mm&r=g","caption":"S&amp;P"},"url":"https:\/\/www.solerpalau.com\/blog\/author\/binaria\/"}]}},"reading_time":"<span class=\"span-reading-time rt-reading-time\"><span class=\"rt-label rt-prefix\"><\/span> <span class=\"rt-time\"> 3<\/span> <span class=\"rt-label rt-postfix\"> min. de lectura<\/span><\/span>","_links":{"self":[{"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/posts\/890","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/users\/10"}],"replies":[{"embeddable":true,"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/comments?post=890"}],"version-history":[{"count":3,"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/posts\/890\/revisions"}],"predecessor-version":[{"id":895,"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/posts\/890\/revisions\/895"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/media\/891"}],"wp:attachment":[{"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/media?parent=890"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/categories?post=890"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.solerpalau.com\/blog\/wp-json\/wp\/v2\/tags?post=890"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}