Range of plate mounted axial flameproof fans. Mounting plate manufactured from galvanised sheet steel fitted with an internal aluminium ring and motor support manufactured from heavy gauge aluminium sheet. The whole assembly is protected by aluminium paint finish B-0920. Impellers manufactured from one piece die-cast aluminium with aerofoil profile fixed blades and finished in a high temperature paint coating (red colour).
Available, depending upon the model, with single or three phase motors in 4, 6 or 8 poles.
Motors
All motors are IP55, Class F insulation.
All motors incorporate ball bearings greased for life.
Electrical supplies:Single phase 230V-50Hz.
Three phase 230/400V-50Hz. 
Additional information
Standard air direction: form (A) configuration (Motor over Impeller).
For the single phase motors, the capacitor is provided not fitted on the fan.
It must be installed outside of the ATEX area or within an electrical main board complying with ATEX Directive.
On request
Air direction: form (B) configuration (Impeller over Motor) only for 450 and 560 models.
                    Available, depending upon the model, with single or three phase motors in 4, 6 or 8 poles.
Motors
All motors are IP55, Class F insulation.
All motors incorporate ball bearings greased for life.
Electrical supplies:
Three phase 230/400V-50Hz.
Additional information
Standard air direction: form (A) configuration (Motor over Impeller).
For the single phase motors, the capacitor is provided not fitted on the fan.
It must be installed outside of the ATEX area or within an electrical main board complying with ATEX Directive.
On request
Air direction: form (B) configuration (Impeller over Motor) only for 450 and 560 models.
                                ATEX versions HDT
On request, explosion proof versions in accordance with ATEX Directive.
For ambient working temperatures from -20ºC to +40ºC.
- ATEX Flameproof-Gas:
In standard ATEX version flameproof motors are without thermal protection.
If used with frequency inverter, flameproof motors with a PTC-type thermal protection must be specified at order.
II 2G Ex d IIB T4
II 2G Ex d IIB+H2 T4
- ATEX Dust:
In standard ATEX version, ATEX motors for dust are without thermal protection.
If used with frequency inverter, ATEX motors for dust with a PTC-type thermal protection must be specified at order.
Suspended flammable particles and non-conductive dust:
II 3D Ex tc IIIB T125ºC
Conductive dust:

                On request, explosion proof versions in accordance with ATEX Directive.
For ambient working temperatures from -20ºC to +40ºC.
- ATEX Flameproof-Gas:
In standard ATEX version flameproof motors are without thermal protection.
If used with frequency inverter, flameproof motors with a PTC-type thermal protection must be specified at order.
II 2G Ex d IIB T4
II 2G Ex d IIB+H2 T4- ATEX Dust:
In standard ATEX version, ATEX motors for dust are without thermal protection.
If used with frequency inverter, ATEX motors for dust with a PTC-type thermal protection must be specified at order.
Suspended flammable particles and non-conductive dust:
II 3D Ex tc IIIB T125ºCConductive dust:
Bathroom Extract Fans
In-line Duct Fans
Wall or Window Extract Fans
Heat Recovery Units
Whole house Extract Units
Acoustic Cabinet Fans
Roof mounted fans
Kitchen Extract Fans 
Kitchen Extract Hoods 
Domestic Ventilation
Domestic Heating
Humidifiers 
Air Treatment Units 
Hand and Hair Dryers 
Plate Mounted Axial Flow 
Cylindrical Cased Axial Flow Fans 
Centrifugal Direct Drive Fan 
Smoke Extract Fans 
Parking Ventilation 
Atex Fans for Explosive Hazardous 
Air Curtains 
Industrial Ventilation
Heating Industrial Range 
Mounting Accessories 
Electrical Accessories
Backward curved centrifugal fans
High pressure centrifugal fans with backward curved impeller
High pressure centrifugal fans with forward curved impeller
Centrifugal fans with forward curved impeller
Double inlet centrifugal fans
Radial Centrifugal fans for transportation of materials
Centrifugal fans for furnace applications