Air handling units with vertical air flow (ascending), designed especially for wall surface installation. They are a good alternative in facilities in which the dimensions of the false ceiling do not allow the integration of the handling units. It fulfils the demands of the ErP-2018.
There are 4 different sizes to move flows from 500 to 8,000 m3/h:
- UTV-2: flow rates from 500 to 2.150 m3/h and 360 mm high.
- UTV-3: flow rates from 1.200 to 4.400 m3/h and 410 mm width.
- UTV-6: flow rates from 2.400 to 6.000 m3/h and 410 mm width.
- UTV-8: flow rates from 4.000 to 8.000 m3/h and 500 mm width.
Frame built with extruded aluminium profiles.
br>Sandwich type panels with 25 mm thick mineral wool insulation inside.
External panelling made of plasticised sheet metal and inner panelling of galvanised sheet metal.
Main module composed of 3 sections: filtration, batteries and fan. Filtration section with built-in very low-pressure loss G4 filter and possibility of mounting a second filter (supplied as accessory).
Battery section with option to equip water batteries, direct expansion or auxiliary electrical resistors.
Fan section allows the orientation of the air outlet upwards or frontwards, by exchanging the front and top panels.
There are 4 different sizes to move flows from 500 to 8,000 m3/h:
- UTV-2: flow rates from 500 to 2.150 m3/h and 360 mm high.
- UTV-3: flow rates from 1.200 to 4.400 m3/h and 410 mm width.
- UTV-6: flow rates from 2.400 to 6.000 m3/h and 410 mm width.
- UTV-8: flow rates from 4.000 to 8.000 m3/h and 500 mm width.
Frame built with extruded aluminium profiles.
br>Sandwich type panels with 25 mm thick mineral wool insulation inside.
External panelling made of plasticised sheet metal and inner panelling of galvanised sheet metal.
Main module composed of 3 sections: filtration, batteries and fan. Filtration section with built-in very low-pressure loss G4 filter and possibility of mounting a second filter (supplied as accessory).
Battery section with option to equip water batteries, direct expansion or auxiliary electrical resistors.
Fan section allows the orientation of the air outlet upwards or frontwards, by exchanging the front and top panels.
Бытовые вытяжные вентиляторы
Вентиляторы для оконно-настенной установки
Канальные вентиляторы
Мультизональные вытяжные вентиляторы
Бытовые кухонные вентиляторы
Вентиляторы для распределения теплого воздуха
Бытовые вентиляторы
Обогреватели и конвекторы
Фены и сушилки для рук
Крышные вентиляторы
Вентиляторы с EC-двигателями
Осевые вентиляторы с монтажной пластиной
Осевые вентиляторы в цилиндрическом корпусе
Струйные вентиляторы
Вентиляторы в корпусе
Центробежные вентиляторы
Пластиковы центробежные вентиляторы
Воздушные завесы и тепловентиляторы
Приточные установки
Приточно-вытяжные установки