ATEX versions available for 3 phase models.
For ambient working temperatures from -20ºC to +40ºC.
- ATEX Flameproof - Gas:
In standard ATEX version flameproof motors are without thermal protection.
If used with frequency inverter,flameproof motors with a PTC-type thermal protection must be specified at order.
II 2G Ex d IIB T4
II 2G Ex d IIB+H2 T4 (with motor Ex d IIC T4)
- ATEX Increased safety - Gas:
II 2G Ex e II T3
- ATEX - Dust:
In standard ATEX version, ATEX motors for dust are without thermal protection.
If used with frequency inverter, ATEX motors for dust with a PTC-type thermal protection must be specified at order.
Combustable flyings and non conductive dust:
II 3D Ex tc IIIB T125ºC
Conductive dust:
II 3D Ex tc IIIC T125ºC ( with motor IP65)
* TGT ATEX Flameproof models 400 and 450mm diameter only available long case LP version.
** TGT ATEX Flameproof models 500 to 1250mm diameter available short case and long case version LP (not available version K or L).
To select TGT ATEX refer to performance curves for THGT, or Easyvent.
Note electrical data may vary for ATEX motors.
For ambient working temperatures from -20ºC to +40ºC.
- ATEX Flameproof - Gas:
In standard ATEX version flameproof motors are without thermal protection.
If used with frequency inverter,flameproof motors with a PTC-type thermal protection must be specified at order.


- ATEX Increased safety - Gas:

- ATEX - Dust:
In standard ATEX version, ATEX motors for dust are without thermal protection.
If used with frequency inverter, ATEX motors for dust with a PTC-type thermal protection must be specified at order.
Combustable flyings and non conductive dust:

Conductive dust:

* TGT ATEX Flameproof models 400 and 450mm diameter only available long case LP version.
** TGT ATEX Flameproof models 500 to 1250mm diameter available short case and long case version LP (not available version K or L).
To select TGT ATEX refer to performance curves for THGT, or Easyvent.
Note electrical data may vary for ATEX motors.
-
ATEX Long casing version “LP”
Large inspection door fitted on Long cased models for ATEX versions, that enables access to the motor terminal box for electrical connection. -
Ex motor versions
Ex versions in accordance to ATEX Directive.