Direct drive, single inlet centrifugal fan. Manufactured from carbon steel protected with cataforesis primer + polyurethane paint finish RAL 7045. 
Working temperature range: -20ºC/+100ºC continuously.
Standard arrangements
• Arrangement 4: Impeller mounted on the B3 motor shaft supported by the pedestal. Version with cooling disk up to +220°C.
• Arrangement 5: Impeller mounted on the B5 motor shaft fitted on the casing sideplate. Version with cooling disk up to +220°C.
• Arrangement 8: Flexible coupling that connects the motor to the fan shaft. Version with cooling disk up to +300°C.
Motors
2, 4 or 6 pole, IE3* high efficiency, three-phase 230/400V 50Hz up to motor size 112 and 400/690V 50Hz for higher motors. IP55 protection, class F.
*From 75kW to 200kW, the motor will be IE4.
On request
• Manufactured from different materials.
• 60 Hz versions.
• Painted in different RAL colour.
• Hot dip galvanised static parts.
• Corrosion proof construction.
• Wear proof construction.
• Motors for special applications.
• Motors suitable for VSD.
• Accessories: Flexible joints, inspection door, casing drain, AV-mounts, protection nets, filter, silencer, inlet discharge governor, valves, dampers.
• Gas tight construction.
• Thermal insulation.
                                                                                     
                    Working temperature range: -20ºC/+100ºC continuously.
Standard arrangements
• Arrangement 4: Impeller mounted on the B3 motor shaft supported by the pedestal. Version with cooling disk up to +220°C.
• Arrangement 5: Impeller mounted on the B5 motor shaft fitted on the casing sideplate. Version with cooling disk up to +220°C.
• Arrangement 8: Flexible coupling that connects the motor to the fan shaft. Version with cooling disk up to +300°C.
Motors
2, 4 or 6 pole, IE3* high efficiency, three-phase 230/400V 50Hz up to motor size 112 and 400/690V 50Hz for higher motors. IP55 protection, class F.
*From 75kW to 200kW, the motor will be IE4.
On request
• Manufactured from different materials.
• 60 Hz versions.
• Painted in different RAL colour.
• Hot dip galvanised static parts.
• Corrosion proof construction.
• Wear proof construction.
• Motors for special applications.
• Motors suitable for VSD.
• Accessories: Flexible joints, inspection door, casing drain, AV-mounts, protection nets, filter, silencer, inlet discharge governor, valves, dampers.
• Gas tight construction.
• Thermal insulation.
                                ATEX versions
On request, explosion proof versions in accordance with ATEX directive for three phase models:
Ambient temperature -20°C to +60°C, ambient pressure (abs.) 0,8 bar to 1,1 bar according to EN 14986.
• Gas:
 2G IIB T2-T3-T4, Motor Exd IIB or ExeII
2G IIB T2-T3-T4, Motor Exd IIB or ExeII
 2G IIB+H2 T2-T3-T4, Motor ExdIIc
2G IIB+H2 T2-T3-T4, Motor ExdIIc
 3G IIB T2-T3-T4, Motor ExnA (only for 3G zone)
3G IIB T2-T3-T4, Motor ExnA (only for 3G zone)
 3G IIB+H2 T2-T3-T4, Motor ExnA (only for 3G zone)
3G IIB+H2 T2-T3-T4, Motor ExnA (only for 3G zone)
• Non-conductive dust
 2D IIIB T125°C-T135°C-T195°C-T295°C
2D IIIB T125°C-T135°C-T195°C-T295°C
 3D IIIB T125°C-T135
3D IIIB T125°C-T135                            
                        On request, explosion proof versions in accordance with ATEX directive for three phase models:
Ambient temperature -20°C to +60°C, ambient pressure (abs.) 0,8 bar to 1,1 bar according to EN 14986.
• Gas:
 2G IIB T2-T3-T4, Motor Exd IIB or ExeII
2G IIB T2-T3-T4, Motor Exd IIB or ExeII 2G IIB+H2 T2-T3-T4, Motor ExdIIc
2G IIB+H2 T2-T3-T4, Motor ExdIIc 3G IIB T2-T3-T4, Motor ExnA (only for 3G zone)
3G IIB T2-T3-T4, Motor ExnA (only for 3G zone) 3G IIB+H2 T2-T3-T4, Motor ExnA (only for 3G zone)
3G IIB+H2 T2-T3-T4, Motor ExnA (only for 3G zone)• Non-conductive dust
 2D IIIB T125°C-T135°C-T195°C-T295°C
2D IIIB T125°C-T135°C-T195°C-T295°C 3D IIIB T125°C-T135
3D IIIB T125°C-T135                            - 
                                              Forward curved impeller 
 Bathroom Extract Fans
Bathroom Extract Fans Air Handling Units
Air Handling Units In-line Duct Fans
In-line Duct Fans Heat Recovery Units
Heat Recovery Units Acoustic Cabinet Fans
Acoustic Cabinet Fans Roof mounted fans
Roof mounted fans Comfort Cooling Range
Comfort Cooling Range Hand and Hair Dryers
Hand and Hair Dryers  Air Purifiers
Air Purifiers Plate Mounted Axial Flow
Plate Mounted Axial Flow  Cylindrical Cased Axial Flow Fans
Cylindrical Cased Axial Flow Fans  Centrifugal Direct Drive Fan
Centrifugal Direct Drive Fan  Parking Ventilation
Parking Ventilation  Smoke Extract Fans
Smoke Extract Fans  Atex Fans for Explosive Hazardous
Atex Fans for Explosive Hazardous  Heating Industrial Range
Heating Industrial Range  In-line Duct Fans
In-line Duct Fans Acoustic Cabinet Fans
Acoustic Cabinet Fans Roof mounted fans
Roof mounted fans Atex Fans for Explosive Hazardous
Atex Fans for Explosive Hazardous  Wall or Window Extract Fans
Wall or Window Extract Fans Whole house Extract Units
Whole house Extract Units Kitchen Extract Fans
Kitchen Extract Fans  Kitchen Extract Hoods
Kitchen Extract Hoods  Backward curved centrifugal fans
Backward curved centrifugal fans High pressure centrifugal fans with backward curved impeller
High pressure centrifugal fans with backward curved impeller High pressure centrifugal fans with forward curved impeller
High pressure centrifugal fans with forward curved impeller Centrifugal fans with forward curved impeller
Centrifugal fans with forward curved impeller Double inlet centrifugal fans
Double inlet centrifugal fans Radial Centrifugal fans for transportation of materials
Radial Centrifugal fans for transportation of materials Centrifugal fans for furnace applications
Centrifugal fans for furnace applications Mounting Accesories
Mounting Accesories  Electrical Accessories
Electrical Accessories
 
     
                                                                            